Danner 02522
Manual do usuario da bomba de auga de accionamento magnético Pondmaster Pond-Mag 250 GPH
Modelo: 02522
Información importante de seguridade
AVISO: Este produto pode expoñelo a produtos químicos, incluído o chumbo, que o Estado de California sabe que causa cancro e defectos de nacemento ou outros danos reprodutivos. Para máis información vai a www.P65Warnings.ca.gov.
- Always disconnect the pump from the power supply before handling or performing any maintenance.
- Ensure the pump is properly grounded.
- Non faga funcionar a bomba se o cable de alimentación está danado.
- Manteña os nenos e as mascotas lonxe da bomba e da fonte de auga durante o funcionamento.
- This pump is designed for water use only. Do not use with flammable liquids.
Produto rematadoview
Descrición
Danner Manufacturing, Inc., Pondmaster Pond-Mag Magnetic Drive Water Pumps, including the 250 GPH model, are engineered for various water movement applications. These pumps offer quiet, efficient, and reliable 24/7 performance, featuring a magnetic impeller assembly and an epoxy-encased power unit. The Pond-Mag 250 GPH pump is ideal for small to medium-sized ponds ranging from 150 to 550 gallons.
Características clave
- Certified to UL or ETL standard for safety.
- Designed for continuous operation without seals to wear out.
- Features a magnetic impeller assembly and an epoxy encased power unit.
- Max. Watts/Amps: 24/0.4, Volts: 120 / 60Hz.
- Inlet: 1/2" FPT, Outlet: 1/2" MPT.
- Cord Length: 18'.
- Includes a rigid pre-filter.
- Operates submerged or inline.
- Equipped with a durable ceramic shaft.
Diagrama do produto

Figure 1: Internal components of the Pondmaster Pond-Mag pump.
Especificacións
| Atributo | Valor |
|---|---|
| Marca | Danner |
| Número de modelo | 02522 |
| Cor | Negro |
| Material | Acrilonitrilo Butadieno Estireno (ABS) |
| Dimensións do produto | 4.5 cm de longo x 3.5 cm de ancho x 3.75 cm de alto |
| Fonte de enerxía | Eléctrico con cable |
| Peso do elemento | 3.7 libras |
| Caudal máximo | 4.16 galóns por minuto (250 GPH) |
| Entrada | 1/2" FPT |
| Outlet | 1/2" MPT |
| Lonxitude do cordón | 18' |
Configuración e instalación
The Pondmaster Pond-Mag pump can be installed either submerged in water or inline (external) depending on your application needs.
Instalación sumergida
- Ensure the pump is placed on a stable, level surface within the pond or water feature.
- Connect appropriate tubing to the pump's outlet (1/2" MPT) for water circulation.
- Ensure the pre-filter is securely attached to the pump's inlet to prevent debris from entering.
- Submerge the pump completely in water before connecting to power.
Inline (External) Installation
- Position the pump on a dry, stable surface near the water source.
- Connect tubing to both the inlet (1/2" FPT) and outlet (1/2" MPT) of the pump. Ensure all connections are watertight.
- The pump must be primed before initial operation in an inline setup. Consult a plumbing professional if unsure about priming procedures.
- Ensure the pump is protected from direct weather exposure if installed outdoors.

Figure 2: Danner Pondmaster Pond-Mag 250 GPH pump.

Figure 3: Rigid pre-filter for the Pondmaster pump.
Instrucións de funcionamento
Once the pump is properly installed and connected to the water system, plug the power cord into a grounded electrical outlet. The pump is designed for continuous operation (24/7 performance). Ensure the pump is always submerged in water if used in a submerged application, or properly primed if used inline, to prevent dry running which can damage the unit.
Monitor the water flow to ensure optimal performance. If flow decreases, refer to the Maintenance or Troubleshooting sections.
Mantemento
Regular maintenance ensures the longevity and efficient operation of your Pondmaster Pond-Mag pump.
- Limpeza do prefiltro: Periodically remove and clean the rigid pre-filter to prevent clogging and maintain optimal water flow. Rinse with clean water.
- Inspección do impulsor: If flow is significantly reduced, disconnect power and inspect the magnetic impeller assembly for debris or blockages. Carefully remove any obstructions.
- Lubricación do eixe: Apply silicone grease to the ceramic shaft and rubber O-ring during reassembly to ensure smooth operation and seal integrity.
- Invernización: In freezing climates, remove the pump from the water feature before the first freeze. Clean thoroughly and store in a frost-free location.
Resolución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| A bomba non arranca nin funciona. | No power to the pump; Impeller jammed; Motor failure. | Check power connection and circuit breaker. Disconnect power and inspect impeller for debris. If problem persists, contact support. |
| Caudal de auga reducido. | Clogged pre-filter; Debris in impeller; Kinked or blocked tubing. | Clean pre-filter. Disconnect power and clear impeller. Check and clear tubing. |
| A bomba é ruidosa. | Debris in impeller; Pump not fully submerged (if applicable); Air in system (if inline). | Clean impeller. Ensure pump is fully submerged. Bleed air from inline system. |
Garantía e Soporte
This Pondmaster Pond-Mag pump comes with a 5 ano de garantía limitadaConserva o comprobante de compra para reclamacións de garantía.