Introdución
This manual provides essential information for the proper installation, operation, and maintenance of your Irritrol 2713APR Electric Anti-Siphon Valve. This valve is designed for residential irrigation applications, offering reliable performance and precise flow control. Please read these instructions thoroughly before installation and use.
Información de seguridade
- Always turn off the main water supply before installing or performing maintenance on the valve.
- Asegúrese de que todas as conexións eléctricas sexan realizadas por un profesional cualificado e que cumpran as normas locais.
- Do not exceed the maximum operating pressure of 150 PSI or maximum water temperature of 110°F (43°C).
- Protexa a válvula das temperaturas de conxelación.
Produto rematadoview
The Irritrol 2713APR is a 1-inch electric anti-siphon valve featuring a stainless bonnet and flow control. It includes a built-in atmospheric vacuum breaker to prevent back-siphonage, ensuring water safety. The valve allows for both electric and manual operation.

Figura 1: Irritrol 2713APR Electric Anti-Siphon Valve. This image shows the grey valve assembly with a black solenoid and flow control knob. The top of the valve is labeled "1" VALVE Irritrol 150 PSI MAX 110°F H₂O MAX ASSEMBLED IN MEXICO".
Configuración e instalación
- Prepare o sitio: Ensure the installation location is above the highest sprinkler head to allow the anti-siphon feature to function correctly. The valve should be easily accessible for maintenance.
- Pechar o subministro de auga: Locate and turn off the main water supply to the irrigation system.
- Conectar fontanería: The valve has 1-inch inlet and outlet connections. Connect the incoming water line to the inlet and the outgoing irrigation line to the outlet. Use appropriate plumbing fittings and thread sealant to ensure watertight connections. The valve is designed for a flow range of 0.25 to 30 GPM and a pressure range of 10 to 150 psi.
- Cableado eléctrico: Connect the valve's solenoid wires to your irrigation controller's common and zone wires. Ensure all electrical connections are secure and protected from moisture. Refer to your irrigation controller's manual for specific wiring instructions.
- Comprobar fugas: Abra lentamente a subministración principal de auga e inspeccione todas as conexións para ver se hai fugas. Aperte as conexións que presenten fugas segundo sexa necesario.
- Initial Flush (Optional): The valve features internal and external bleed (flush mode) for manual operation. To flush the system, you can manually activate the valve to clear any debris before automatic operation.
Instrucións de funcionamento
- Operación automática: Once installed and wired, the valve will operate automatically according to the programming of your irrigation controller.
- Operación manual:
- To manually open the valve, turn the solenoid counter-clockwise approximately one-half turn.
- To manually close the valve, turn the solenoid clockwise until snug. Do not overtighten.
- Alternatively, use the external bleed screw (if present) to manually open the valve for flushing or testing.
- Axuste de control de fluxo: The valve is equipped with a flow control knob.
- To decrease water flow, turn the flow control knob clockwise.
- To increase water flow, turn the flow control knob counter-clockwise.
- Adjust the flow control to achieve the desired sprinkler performance for the zone.
Mantemento
Regular maintenance ensures the longevity and optimal performance of your Irritrol valve.
- Invernización: In areas subject to freezing temperatures, properly winterize your irrigation system, including the valve, to prevent damage. This typically involves draining water from the system or using an air compressor to blow out the lines.
- Comprobación de residuos: Periodically inspect the valve for any debris that may have entered the system and could impede proper operation. If necessary, turn off the water, disassemble the valve bonnet (by unscrewing the screws on the top), and clean any internal components.
- Solenoid Inspection: Check the solenoid for proper function. If the valve fails to open or close electrically, the solenoid may need to be replaced.
- Inspección do diafragma: If the valve is not operating correctly, the diaphragm inside may be worn or damaged. Turn off the water, remove the bonnet, and inspect the diaphragm for tears or blockages. Replace if necessary.
Resolución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| A válvula non se abre | No power to solenoid, clogged diaphragm, faulty solenoid, low water pressure. | Check wiring connections, clean diaphragm, test/replace solenoid, verify water pressure. |
| Valve does not close completely (leaks) | Debris in valve, worn diaphragm, overtightened flow control. | Turn off water, clean internal components, replace diaphragm, loosen flow control slightly. |
| Baixo caudal de auga | Partially closed flow control, clogged filter/screen, low main water pressure. | Adjust flow control, clean any internal screens, check main water supply. |
| Water continuously flows (valve stuck open) | Debris preventing diaphragm from sealing, damaged diaphragm, faulty solenoid. | Turn off water, clean valve internals, replace diaphragm, replace solenoid. |
Especificacións
- Modelo: 2713APR
- Material: Stainless Steel (Bonnet)
- Tamaño da conexión de entrada/saída: 1 polgadas
- Tipo de conexión de entrada: Brida
- Tipo de conexión de saída: NPT
- Número de portos: 2
- Rango de caudal: 0.25 a 30 GPM
- Rango de presión: 10 a 150 PSI
- Temperatura máxima da auga: 110 °F (43 °C)
- Dimensións do produto (L x W x H): 6 x 6.88 x 3 polgadas
- Peso do artigo: 1.2 libras
- Fabricante: Irritrol
- UPC: 090258044253