White-Rodgers 90-118E

White-Rodgers Fan Control Center Model 90-118E Instruction Manual

Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of the White-Rodgers Fan Control Center, Model 90-118E. This device is designed to manage fan operations in heating, ventilation, and air conditioning (HVAC) systems. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Información de seguridade

ADVERTENCIA: Risco de descarga eléctrica. Desconecte a alimentación antes da instalación ou do mantemento.

  • Installation must be performed by a qualified technician in accordance with all local and national electrical codes.
  • Ensure the power supply to the HVAC system is completely disconnected before beginning any work.
  • Verify all wiring connections are secure and correct to prevent damage to the unit or system.
  • Non utilice a unidade se algunha parte está danada.

Produto rematadoview

The White-Rodgers Fan Control Center 90-118E is a robust component designed for reliable fan control. Key features include:

  • Plug-in style relay: Facilitates easy field replacement.
  • Pre-stripped, color-coded leads: Simplifies wiring connections.
  • Five combination screw/solder terminals: Para baixo voltagcableado.
  • Standard double-throw relays: Capable of handling both one and two-speed motors.
  • Mounting design: Suitable for a 4-inch electrical box.
White-Rodgers Fan Control Center 90-118E with wiring

Figura 1: White-Rodgers Fan Control Center 90-118E. This image shows the control center from an angled perspective, highlighting the metal mounting plate, the central transformer component, and the pre-stripped, color-coded wires neatly bundled and connected to the terminal block.

Instalación

Ferramentas necesarias:

  • Desaparafusador (Phillips e/ou de punta plana)
  • Pelacables/cortadores
  • Multímetro (para verificación)

Pasos de instalación:

  1. Desconectar a enerxía: Turn off the main power supply to the HVAC system at the circuit breaker. Verify power is off using a multimeter.
  2. Remove Existing Unit (if applicable): Carefully disconnect and remove the old fan control center, noting all wiring connections.
  3. Montar a nova unidade: The 90-118E is designed for mounting in a standard 4-inch electrical box. Secure the unit using appropriate screws.
  4. Conexións de cable: Connect the pre-stripped, color-coded leads to the corresponding terminals in your HVAC system. Refer to your specific HVAC system's wiring diagram for accurate connections. The unit features five combination screw/solder terminals for low voltagcableado.
  5. Relay Installation: The plug-in style relay should be securely seated in its receptacle.
  6. Verificar conexións: Double-check all wiring connections for tightness and correctness.
  7. Restaurar enerxía: Once all connections are verified, restore power to the HVAC system.

Operación

The White-Rodgers Fan Control Center 90-118E operates automatically as an integral part of your HVAC system. It receives signals from the thermostat or other control devices to activate and deactivate the fan motor. Its primary function is to provide reliable switching for fan operations, supporting both single and two-speed motors.

  • Upon receiving a call for fan operation (e.g., from a thermostat), the internal relay will energize, closing the appropriate contacts to power the fan motor.
  • When the call for fan operation ceases, the relay de-energizes, opening the contacts and turning off the fan motor.
  • The double-throw relay design allows for flexible control of different fan motor types and speeds, depending on the system's configuration.

Mantemento

The White-Rodgers Fan Control Center 90-118E is designed for minimal maintenance. Regular inspection by a qualified technician is recommended as part of routine HVAC system checks.

  • Inspección anual: During annual HVAC system servicing, have a technician inspect the control center for any signs of wear, corrosion, or loose connections.
  • Limpeza: Ensure the unit is free from dust and debris. Use a soft, dry brush or compressed air for cleaning. Do not use liquid cleaners.
  • Substitución do relé: The plug-in style relay is designed for easy replacement if it fails. Ensure power is disconnected before attempting to replace the relay.

Resolución de problemas

If you experience issues with your fan control center, refer to the following common troubleshooting steps. For complex issues, contact a qualified HVAC technician.

  • O ventilador non se acende:
    • Check if the main power supply to the HVAC system is on.
    • Verify the thermostat is calling for fan operation.
    • Inspeccione as conexións do cableado para ver se hai frouxeza ou danos.
    • Test the relay for continuity (requires a multimeter and electrical knowledge).
  • Fan Running Continuously:
    • Check if the thermostat is stuck in the "Fan ON" position.
    • The relay contacts may be fused closed. The relay may need replacement.
  • Intermittent Fan Operation:
    • Conexións de cableado soltas.
    • Faulty relay or control board in the HVAC system.
  • Sen baixo voltage (24V) Output:
    • Check the primary 120V input to the control center.
    • The internal transformer may be faulty.

Especificacións

CaracterísticaEspecificación
Número de modelo90-118E
Primary VAC120 V
Secondary VAC24 V
Tipo de conectorEnchufe
Tipo de contactoNormally Open (SPNO/SPNC)
Tipo de montaxePlug In Mount (for 4-inch box)
Modo de operaciónAutomático
Bobina Voltage24 voltios
Vol. máximo de conmutacióntage24 voltios
Dimensións do produto1 x 1 x 1 polgadas (aproximado)
Peso do elemento1.98 libras (aproximadamente)
FabricanteWhite Rodgers
País de fabricaciónEstados Unidos

Garantía e Soporte

For warranty information and technical support, please refer to the official White-Rodgers websitio web ou póñase en contacto co servizo de atención ao cliente. Garde o recibo de compra para reclamacións de garantía.

White-Rodgers Customer Service: Visit Emerson.com/contact-us (White-Rodgers is an Emerson brand)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.