Perel E305DIN1

Perel E305DIN1 DIN Rail Week Timer Instruction Manual

Model: E305DIN1

1. Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of your Perel E305DIN1 DIN Rail Week Timer. Please read this manual thoroughly before using the device to ensure proper function and safety. The Perel E305DIN1 is designed for precise daily and weekly control of electrical circuits.

2. Características

The Perel E305DIN1 DIN Rail Week Timer offers a range of functionalities for efficient time management of electrical devices:

  • Daily and Weekly Programming: Allows for flexible scheduling across days and weeks.
  • 8 ON/OFF Program Locations: Configure up to 8 distinct ON and OFF switching times.
  • Pantalla LCD: Clear display of time, day of the week, and current operating status.
  • NiMH Backup Battery: Integrated battery provides up to 200 hours of autonomy after a full charge, preserving settings during power outages.
  • 3-Way Manual Override: Easily switch between ON, OFF, and AUTO modes manually.
  • Opcións de montaxe: Designed for DIN rail mounting or wall mounting using the included bracket.
  • Funda protectora transparente: Provides protection for the display and controls.

3. Configuración e instalación

Aviso: Installation should only be performed by a qualified electrician. Ensure the main power supply is disconnected before commencing installation.

3.1 Montaxe

The E305DIN1 timer can be mounted in two ways:

  • Montaxe en carril DIN: Snap the timer onto a standard 35mm DIN rail within an electrical enclosure.
  • Montaxe na parede: Use the provided bracket to secure the timer to a wall. Ensure the mounting surface is stable and capable of supporting the device.

3.2 Conexión eléctrica

Refer to the wiring diagram provided with the device for specific connection points. General steps include:

  1. Connect the main power supply (220-250VAC, 50Hz) to the designated input terminals.
  2. Connect the load (device to be controlled) to the output terminals. Ensure the load's specifications do not exceed the timer's maximum output capacity (16A resistive, 8A inductive).
  3. Comprobe dúas veces que todas as conexións estean ben apertadas e correctas antes de restablecer a alimentación.
Perel E305DIN1 DIN Rail Week Timer with transparent cover

Image: Perel E305DIN1 DIN Rail Week Timer. This image shows the front view of the timer, highlighting its LCD display, control buttons, and transparent protective cover.

4. Instrucións de funcionamento

After installation and power-up, the timer's internal battery will charge. Allow sufficient time for the battery to charge for optimal backup functionality.

4.1 Axuste da hora e do día actuais

  1. Preme o RELOXO botón.
  2. Mentres sostén RELOXO, prema o DÍA botón para configurar o día actual da semana.
  3. Mentres sostén RELOXO, prema o HORA botón para configurar a hora actual.
  4. Mentres sostén RELOXO, prema o MIN botón para configurar o minuto actual.

4.2 Programación dos tempos de acendido/apagado

The timer allows for up to 8 ON/OFF program pairs.

  1. Preme o PROG button once to enter program mode. The display will show '1 ON'.
  2. Usa o DÍA, HORA, e MIN buttons to set the desired ON time for program 1.
  3. Preme PROG again. The display will show '1 OFF'.
  4. Usa o DÍA, HORA, e MIN buttons to set the desired OFF time for program 1.
  5. Repeat steps 1-4 for programs 2 through 8.
  6. Preme o RELOXO button to exit program mode and return to normal operation.

4.3 Manual Override Function

The manual override function allows you to temporarily change the timer's output state without affecting programmed settings.

  • Preme o MANUAL botón para percorrer os modos:
  • ACTIVADO: The output is continuously ON, overriding any programmed OFF times.
  • OFF: The output is continuously OFF, overriding any programmed ON times.
  • AUTOMÁTICO: The timer operates according to the programmed ON/OFF schedules.

5. Mantemento

The Perel E305DIN1 timer requires minimal maintenance.

  • Limpeza: Limpe o exterior cun pano suave e seco. Non empregue produtos de limpeza abrasivos nin solventes.
  • Copia de seguridade da batería: The internal NiMH battery is designed for long life. If the timer frequently loses its settings during power outages, pode ser necesario que un técnico cualificado substitua a batería.
  • Condicións ambientais: Ensure the timer operates within its specified temperature range (-10°C to 40°C) and avoid excessive humidity or direct sunlight.

6 Solución de problemas

If you encounter issues with your Perel E305DIN1 timer, refer to the following common problems and solutions:

  • O temporizador non se acende/apaga segundo a programación:
    • Comproba se o temporizador está activado AUTO mode. If it's in ON or OFF manual override, it will ignore programs.
    • Verify that the programmed ON/OFF times are correctly set and correspond to the current day.
    • Ensure the current time and day are accurately set on the timer.
  • A pantalla está en branco ou parpadea:
    • Check the main power supply to the timer.
    • If power is present, the internal backup battery might be completely discharged. Allow the timer to be powered for several hours to recharge the battery.
  • O temporizador perde a configuración despois de apagar a alimentacióntage:
    • The internal NiMH backup battery may not be fully charged or may be at the end of its lifespan. Ensure the timer is continuously powered for at least 24 hours to fully charge the battery. If the issue persists, the battery may need replacement.
  • Time drift (timer becomes inaccurate over time):
    • The timer has a specified accuracy of ±1 minute per month. Minor adjustments may be necessary periodically. If the drift is significantly higher, contact support.

Se estes pasos non resolven o problema, ponte en contacto co servizo de atención ao cliente.

7. Especificacións

Below are the technical specifications for the Perel E305DIN1 DIN Rail Week Timer:

Fonte de alimentación220 ~ 250VAC / 50Hz
Output (Resistive Load)16A @ 230VAC, max. 3680W
Output (Inductive Load)8A @ 230VAC (cos µ = 0.4)
Intervalo mínimo de conmutación1 minuto
Consumo de enerxía4.4 W
Temperatura de funcionamento-10°C a 40°C
Precisión horaria± 1 minuto ao mes
Batería de respaldoNiMH, up to 200h autonomy
MontaxeDIN Rail or Wall Mount
MaterialPlástico
CorTransparente

8. Garantía e soporte

This Perel product is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the Perel customer service department.

Garde o seu recibo de compra como xustificante de compra para efectos de garantía.

Ask a question about this manual