Leviton 25249-TFB

Leviton 25249-TFB 15 Amp 125 voltios TampManual de instrucións do receptáculo dúplex resistente aos er

Model: 25249-TFB

Introdución

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton 15 Amp, 125 Volt, Tamper-Resistant Duplex Receptacle (Model 25249-TFB). This commercial-grade, self-grounding receptacle features a straight blade design and a brass finish, engineered for demanding environments such as hotels, schools, hospitals, and commercial office buildings. It is designed to withstand rigorous use and offers enhanced safety features.

Información de seguridade

AVISO: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

Proposición 65 Advertencia: Este produto pode conter produtos químicos que o Estado de California sabe que causan cancro e defectos de nacemento ou outros danos reprodutivos. Lavar as mans despois da manipulación.

  • Do not use this device with aluminum wiring. Use only with copper or copper-clad wire.
  • Asegúrate de que todas as conexións estean ben axustadas e seguras para evitar o sobrequecemento.
  • This receptacle is tamper-resistant, designed to prevent insertion of foreign objects into the receptacle openings.
  • Do not exceed the specified electrical ratings of 15 Amps e 125 voltios.

Características do produto

  • TampDeseño resistente a er: Meets NEC 2020 article 406.12, providing enhanced safety by preventing the insertion of single objects into the receptacle openings.
  • Grao comercial: Built to withstand demanding environments, ensuring durability and long-term performance.
  • Autoconexión a terra: Features an integral self-grounding clip for quick and easy installation into a properly grounded metal box.
  • Construción duradeira: Thermoplastic receptacle face and body resist breakage.
  • Ready-To-Wire Unit: All-in-one design facilitates quick and easy installation.
Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish

Image: Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish. This image shows the front view of the receptacle with its brass faceplate and two tamptomas resistentes a er.

Configuración e instalación

Installation of electrical devices should only be performed by qualified personnel. Always ensure power is disconnected before beginning any work.

  1. Apagar a enerxía: Locate the circuit breaker or fuse that supplies power to the outlet where the receptacle will be installed. Turn it off and verify that power is off using a voltagprobador.
  2. Retirar o receptáculo antigo (se corresponde): Carefully remove the existing wall plate and receptacle from the electrical box. Disconnect the wires, noting their connections (hot, neutral, ground).
  3. Prepare fíos: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wires are straight.
  4. Conecte cables:
    • Conecta o quente (negro) wire to the brass-colored screw terminal.
    • Conecta o neutro (branco) wire to the silver-colored screw terminal.
    • Conecta o ground (green or bare copper) wire to the green screw terminal. This receptacle is self-grounding, meaning it will ground itself to a properly grounded metal box via its mounting strap.
    Asegúrese de que todas as conexións dos cables estean firmes e seguras.
  5. Receptáculo de montaxe: Carefully fold the wires into the electrical box, then insert the new receptacle and secure it with the mounting screws provided.
  6. Instalar placa de parede: Attach the decorative wall plate (sold separately) over the receptacle.
  7. Restaurar enerxía: Volva conectar a corrente no disxuntor ou na caixa de fusibles.
  8. Proba: Test the receptacle with a known working appliance or receptacle tester to ensure proper function.
Leviton 25249-TFB Receptacle Back View

Imaxe: Costas view of the Leviton 25249-TFB receptacle, showing the screw terminals for wiring connections (hot, neutral, ground).

Instrucións de funcionamento

The Leviton 25249-TFB Tamper-Resistant Duplex Receptacle operates like a standard electrical outlet, with added safety features.

  • Conectando: Insert the plug of your appliance or device firmly into one of the two receptacle openings. The tamper-resistant shutters may require slightly more force to open than a traditional receptacle. Ensure both prongs are inserted simultaneously and evenly.
  • Desconectando: Grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
  • Capacidade de carga: Do not overload the receptacle. The total current drawn by all connected devices should not exceed 15 Amps.

Mantemento

The Leviton 25249-TFB receptacle requires minimal maintenance.

  • Limpeza: To clean the receptacle face, ensure power is off at the circuit breaker. Use a soft, damp pano. Non use produtos de limpeza ou disolventes abrasivos.
  • Inspección: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and have the receptacle inspected and replaced by a qualified electrician.
  • Consideracións ambientais: While durable, avoid exposing the receptacle to excessive moisture or extreme temperatures beyond its operational specifications.

Resolución de problemas

ProblemaCausa posibleSolución
Non hai enerxía no receptáculo.Disxuntor disparado ou fusible fundido. Conexión de cableado solta.Check and reset the circuit breaker or replace the fuse. If problem persists, turn off power and check wiring connections. Consult an electrician if necessary.
O enchufe non se introduce facilmente.TampOs obturadores resistentes ás xeringas están activados.Ensure both prongs of the plug are aligned and inserted simultaneously and firmly. Do not force the plug.
O receptáculo ten unha sensación de calor.Overloaded circuit. Loose wiring connection.Unplug some devices to reduce load. Turn off power and check wiring connections. If warmth persists, consult an electrician immediately.

Especificacións

  • Modelo: 25249-TFB
  • Ampera: 15 Amps
  • Voltage: 125 voltios
  • Configuración: 5-15R
  • Número de polos: 2
  • Número de cables: 3
  • Conexión a terra: Auto-terra
  • Material: Nylon (body), Brass (finish)
  • Cor: Acabado latón
  • Normas e certificacións: UL 498, CSA C22.2, NOM 057 Approved
  • Total de tomas de corrente: 2

Garantía e Soporte

Garantía: This Leviton product is backed by a 10-Year Limited Warranty. For detailed warranty terms and conditions, please refer to the official Leviton websitio ou póñase en contacto co servizo de atención ao cliente.

Atención ao cliente: For technical assistance, troubleshooting, or warranty claims, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the product packaging or the Leviton websitio.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.