Introdución
This manual provides essential instructions for the safe and effective operation, setup, and maintenance of your Horizon SF-918 OCS-L Digital Hanging Scale. Please read this manual thoroughly before using the device to ensure proper function and to prevent damage or injury.

Image: The Horizon SF-918 OCS-L Digital Hanging Scale, showcasing its robust design with a top shackle and a lower weighing hook.
Información de seguridade
- Do not exceed the maximum weight capacity of 300 kg (600 lbs). Overloading can damage the scale and pose a safety risk.
- Ensure the scale is securely suspended from a stable and appropriate support structure before attaching any load.
- Always stand clear of the load during weighing.
- Avoid dropping or subjecting the scale to severe impacts.
- Do not immerse the scale in water or expose it to excessive moisture. While durable, it is not waterproof.
- Manter fóra do alcance dos nenos.
Contido do paquete
Verifica que todos os elementos estean presentes no paquete:
- Horizon SF-918 OCS-L Digital Hanging Scale
- Top Shackle (pre-attached)
- Bottom Weighing Hook
- 2 x pilas AAA

Image: The Horizon SF-918 OCS-L Digital Hanging Scale as packaged, showing the scale, hooks, and included AAA batteries.
Configuración
- Instalación da batería:
- Localice o compartimento da batería na parte traseira da báscula.
- Abra a tapa da batería.
- Insira dúas (2) pilas AAA, asegurándose de manter a polaridade correcta (+/-).
- Close the battery cover securely. Ensure the batteries are firmly seated to prevent intermittent power loss during use.

Imaxe: Unha detallada view of the battery compartment, showing the correct placement of two AAA batteries.
- Attaching the Bottom Hook:
- The top shackle is typically pre-attached.
- Attach the provided bottom weighing hook to the lower attachment point of the scale. Ensure it is securely fastened.

Image: A close-up of the robust top shackle, indicating the secure attachment mechanism for suspending the scale.
Instrucións de funcionamento
The scale features a 1-inch illuminated LCD display and three control buttons: Power, HOLD/UNIT, and TARE.

Imaxe: Unha detallada view of the scale's digital display and control buttons, showing the current weight reading and unit.
- Encendido/apagado:
- Preme o Poder botón (
) to turn the scale ON. The display will show "88888" then "0.0" with the current unit. - Manteña premido o Poder button for 3 seconds to turn the scale OFF.
- Preme o Poder botón (
- Unit Selection (Kg/Lb/N):
- With the scale ON and displaying "0.0", press the HOLD/UNIT button to cycle through the available weighing units: Kilograms (kg), Pounds (lb), and Newtons (N).
- Función de tara:
- To weigh items in a container, first hang the empty container on the hook.
- Preme o TAREAR botón. A pantalla restablecerase a "0.0".
- Engada os artigos que se van pesar no recipiente. A pantalla mostrará o peso neto dos artigos.
- Función de retención:
- While weighing a load, press the HOLD/UNIT button to lock the current weight reading on the display. The "HOLD" indicator will appear.
- Preme o HOLD/UNIT button again to release the hold function and return to live weighing.
- Note: This function holds the weight displayed at the moment the button is pressed, not necessarily the maximum weight achieved during the lift.
- Procedemento de pesaxe:
- Ensure the scale is ON and displaying "0.0" in your desired unit.
- Carefully attach the item to be weighed to the bottom hook.
- Allow the load to stabilize. The display will show the weight. The reading stable time is typically less than 10 seconds.
- Remove the load once the reading is taken.
- Apagado automático:
- The scale will automatically turn off after approximately 3 minutes of inactivity to conserve battery life. This feature cannot be adjusted or disabled.
Mantemento
- Limpeza: Limpe a báscula cun suave, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish and electronic components. Avoid getting water inside the unit.
- Almacenamento: Garda a báscula nun lugar seco e fresco, lonxe da luz solar directa e de temperaturas extremas. Se a gardas durante un período prolongado, retira as pilas para evitar fugas.
- Substitución da batería: When the battery indicator appears on the display, replace both AAA batteries promptly to ensure accurate readings and proper operation.
Resolución de problemas
- A escala non se activa:
- Check battery installation. Ensure batteries are inserted with correct polarity and are fully charged. Replace batteries if necessary. Ensure battery contacts are clean and free from corrosion.
- Lecturas inexactas:
- Ensure the scale is suspended stably and not swinging. Verify the load is not touching any other surfaces. Check if the scale has been overloaded. Perform a tare operation before weighing.
- Scale turns off unexpectedly:
- This may be due to the 3-minute auto-off feature if no activity is detected. If it turns off during active weighing, check battery contact and ensure batteries are securely seated and not loose.
- Display shows "O-Ld" or similar:
- This indicates an overload condition. Remove the load immediately to prevent damage to the scale. Do not exceed the 300 kg / 600 lbs capacity.
Especificacións
| Característica | Especificación |
|---|---|
| Modelo | SF-918 OCS-L |
| Capacidade | 300 kg / 600 lb |
| Precisión | 0.1 kg / 0.1 lb |
| Starting Weight | <200 g |
| Modos de pesaxe | Kilograms (kg), Pounds (lb), Newtons (N) |
| Mostrar | 1-inch Illuminated LCD |
| Apagado automático | 3 minutos de inactividade |
| Rango de Tara | Capacidade total |
| Tempo de lectura estable | <10 segundos |
| Poder | 2 pilas AAA (incluídas) |
| Dimensións (D x W x H) | 3.1 x 12 x 1.5 polgadas (aproximado) |
| Peso | 23 onzas (1.37 libras) |
| Material | Aluminio Casing, Stainless Steel Load Receptor |
| Cor | Vermello |
Garantía e Soporte
For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official Horizon websitio. Garde o recibo da compra como xustificante da mesma.