1. Introdución

The Tsurumi Pump 50UT2.75S is a robust cast iron submersible sewage pump designed for efficient transfer of wastewater and sewage. It is suitable for various applications including draining sewage from factories, residences, hotels, and restaurants, as well as transferring wastewater between storage tanks.

This pump is engineered to handle solids up to 1.4 inches in diameter and can achieve a pumping rate of up to 95 gallons per minute (GPM).

Tsurumi Pump 50UT2.75S Cast Iron Sewage Pump

Figure 1: Tsurumi Pump 50UT2.75S Cast Iron Sewage Pump. This image shows the main unit of the submersible sewage pump, highlighting its durable cast iron construction and compact design.

2. Características clave

  • Large Passage Diameter: Capable of handling liquids containing various solids up to 1.4 inches in diameter.
  • Ball Float: Enables automatic operation based on water level, ensuring efficient and hands-free pumping.
  • Portabilidade: Equipped with a handle for easy carrying and movement, facilitating installation and relocation.
  • Construción duradeira: Features a dual inner mechanical seal with silicon carbide faces to prevent leakage and extend pump life.
  • Protección do motor: Built-in thermal motor protection prevents overheating, enhancing reliability and longevity.
  • Resistencia á corrosión: Utilizes a resin impeller that is resistant to wear and corrosion, suitable for demanding environments.
  • Power Cord and Discharge: Comes with a 32-foot power cord and a 2-inch discharge port for easy connection.
Tsurumi Pump 50UT2.75S Features Diagram

Figure 2: Key Features of the 50UT2.75S Pump. This diagram illustrates the large passage diameter for solids, the ball float for automatic operation, and the integrated handle for portability.

3. Configuración e instalación

Proper setup is crucial for the optimal performance and longevity of your Tsurumi 50UT2.75S pump. Ensure all safety precautions are followed before beginning installation.

3.1 Colocación

The pump is designed for submersible use. Place the pump on a solid, level surface in the liquid to be pumped. Ensure it is not resting directly on soft sediment or debris that could impede its operation or clog the intake.

3.2 Discharge Connection

Connect a standard 2-inch hose or pipe to the pump's discharge port. Secure the connection to prevent leaks and ensure efficient flow. For permanent installations, consider using a check valve to prevent backflow.

3.3 Conexión de alimentación

The pump operates on 115V power. Connect the 32-foot power cord to a grounded electrical outlet. Ensure the power supply matches the pump's voltage requirements. Avoid using extension cords if possible; if necessary, use a heavy-duty, outdoor-rated extension cord of appropriate gauge.

4. Instrucións de funcionamento

The Tsurumi 50UT2.75S pump is designed for automatic operation, making it user-friendly for continuous or intermittent pumping tasks.

4.1 Funcionamento automático

The integrated ball float switch controls the pump's operation. When the water level rises to a predetermined point, the float activates the pump, initiating the pumping cycle. The pump will continue to operate until the water level drops, causing the float to deactivate the pump.

4.2 Funcionamento manual (se corresponde)

Refer to the specific wiring diagram or control panel instructions if manual override or continuous operation is desired for specific applications. Always ensure the pump is fully submerged during operation to prevent dry running and potential damage.

Tsurumi Pump 50UT2.75S Performance Curve

Figure 3: Performance Curve for 50UT2.75S. This graph illustrates the relationship between total head (ft) and capacity (gal/min) for the 1 HP, 60Hz pump, indicating its operational efficiency.

Tsurumi Pump 50UT2.75S Application Examples

Figure 4: Typical Applications for the 50UT2.75S Pump. This image shows examples of the pump's use in residential septic systems and for raw sewage handling, demonstrating its versatility.

5. Mantemento

Regular maintenance ensures the longevity and reliable performance of your Tsurumi 50UT2.75S pump. Always disconnect power before performing any maintenance.

5.1 Inspección xeral

  • Periodically inspect the pump for any visible damage to the casing, power cord, or discharge port.
  • Check for any signs of excessive wear or corrosion, especially on the resin impeller.
  • Ensure the dual inner mechanical seal is intact and not leaking.

5.2 Limpeza

Remove any accumulated debris or foreign objects from the pump's intake screen and around the impeller. This prevents blockages and maintains optimal flow. The pump's design allows for handling solids, but excessive buildup can reduce efficiency.

5.3 Almacenamento

If storing the pump for an extended period, clean it thoroughly and store it in a dry, protected area to prevent damage from freezing temperatures or environmental exposure.

6 Solución de problemas

This section provides guidance for common issues you might encounter with your Tsurumi 50UT2.75S pump. For complex problems, contact Tsurumi (America), Inc. support.

ProblemaCausa posibleSolución
A bomba non arranca nin funciona.No power supply; Float switch stuck or obstructed; Thermal overload activated.Check power connection and circuit breaker; Clear any obstructions around the float switch; Allow pump to cool down if thermal protection activated.
A bomba funciona pero non sae auga ou o caudal é baixo.Discharge hose/pipe clogged or kinked; Intake screen blocked; Impeller obstructed.Inspect and clear discharge line; Clean intake screen; Inspect and clear impeller (disconnect power first).
A bomba acéndese e apágase con frecuencia.Float switch range too narrow; Water level fluctuating rapidly.Adjust float switch position if possible; Ensure proper sump/pit size for application.
Ruído ou vibración inusual.Debris in pump; Worn bearings; Improper installation.Disconnect power and check for debris; Contact service for internal component issues; Re-check installation for stability.

7. Especificacións

AtributoValor
Número de modelo50UT2.75S
MarcaBomba Tsurumi
Poder1 HP
Voltage115 V
Tamaño da descarga2 polgadas
Caudal máximo95 GPM (360 litros por minuto)
Maximum Solids Handling1.4 polgadas
Lonxitude do cable de alimentación32 pés
MaterialFerro fundido
Peso do elemento45 libras
Dimensións do produto9.53 x 0.01 x 0.02 polgadas
Altura máxima de elevación13 centímetros (aprox. 5 polgadas)
CertificaciónsUL & CSA certified
Tsurumi Pump 50UT2.75S Product Specifications Summary

Figure 5: Summary of 50UT2.75S Product Specifications. This image provides a quick overview of key technical data for the pump.

8. Vídeo oficial do produto

Video 1: Tsurumi Pump, "Built for Work". This video provides an overview of Tsurumi Pump's commitment to reliable pumping solutions and highlights various applications of their products, including wastewater treatment, mining, construction, and flood remediation.

9. Garantía e soporte

The Tsurumi 50UT2.75S pump comes with a GARANTÍA DE 2 ANOS. This product is UL & CSA certified, ensuring compliance with safety and quality standards.

For any questions, concerns, technical assistance, or warranty claims, please contact Tsurumi (America), Inc. directly. Their dedicated team is available to provide effective solutions and support for your water projects.

You can find more information and contact details on the official Tsurumi Pump websitio web ou a través do seu distribuidor autorizado.

Why Choose Tsurumi Pump

Figure 6: Reasons to Choose Tsurumi. This graphic emphasizes Tsurumi's reputation for being a trusted brand, offering durability, versatility, efficiency, and excellent support.

© 2023 Tsurumi Pump. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.