Thank you for choosing the BN-LINK Digital Countdown Wall Timer Switch. This device is designed to provide convenient and energy-efficient control over your lights and exhaust fans. With its simple push-button operation and preset countdown options, you can easily automate shut-off times, helping to conserve energy and enhance your daily routine. This manual provides detailed instructions for installation, operation, and safety to ensure optimal performance and longevity of your timer switch.
O que hai na caixa
- BN-LINK Digital Countdown Wall Timer Switch
- Placa de parede
- Nuts de arame
- Parafusos de montaxe
- Manual de instrucións

Image: Package contents showing the timer switch, wire nuts, and wall plate.
Especificacións
| Modelo | BND-60/U110b-1 |
| Modo de operación | ACENDIDO APAGADO |
| Valoración actual | 15 Amps |
| Vol. Operativotage | 125 voltios |
| Tipo de contacto | Normalmente pechado |
| Tipo de conector | Clamp |
| Tipo de cambio | Pulsador |
| Terminal | Parafuso |
| Material | Plástico |
| Dimensións do artigo (L x W x H) | 4.2 x 1.8 x 2 polgadas |
| Tipo de circuíto | 1 vías |
| Tipo de montaxe | Soporte de parede |
| Tipo de actuador | Pulsador |
| Número de postos | 1 |
| Clasificación de temperatura superior | 122 graos Fahrenheit |
| Método de control | Toca |
| Wattage | 1875 vatios |
| Cor | Branco |
| Clasificación de protección internacional | IP54 |
| Certificación | ETL Listed (Conforms to UL Std. 60730-1, 60730-2-7) |

Image: Size details of the timer switch, including its dimensions and included accessories like wire nuts and face plate.
Información importante de seguridade
- AVISO: Para evitar incendios, descargas eléctricas ou a morte, desconecte a alimentación no disxuntor ou na caixa de fusibles e comprobe que a alimentación estea desconectada antes de conectar o cableado.
- Este dispositivo require un Fío neutro for proper operation. Ensure your electrical box has a neutral wire available.
- For single-pole installations only. Do not use in 3-way or multi-way switch applications.
- Consulte cun electricista cualificado se ten dúbidas sobre algunha parte do proceso de instalación.
- Rated 125V, 60 Hz, 15A/1875W Resistive or General Purpose, 10A/1250W Ballast or Tungsten, ½ HP, TV-5. Do not exceed these ratings.
Instrucións de instalación
- Apagar a enerxía: Before beginning any electrical work, ensure the power to the switch location is turned off at the circuit breaker or fuse box. Verify power is off using a voltagprobador.
- Eliminar o interruptor existente: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
- Identificar os cables: Identify the following wires in your electrical box:
- Fío quente (liña): Typically black, brings power from the circuit breaker.
- Cable de carga: Typically black, connects to the fan or light fixture.
- Fío neutro: Typically white, required for this timer switch.
- Fío de terra: Typically green or bare copper.
- Cablear o interruptor temporizador: Connect the wires from your electrical box to the corresponding wires on the BN-LINK timer switch using the provided wire nuts.
- Conecta o Fío quente from the wall to the Arame negro do temporizador.
- Conecta o Fío de carga desde o aparello ata o Arame Vermello do temporizador.
- Conecta o Fío neutro from the wall to the Arame Branco do temporizador.
- Conecta o Fío de terra from the wall to the Arame Verde do temporizador.
- Montar o interruptor: Carefully push the wired timer switch into the electrical box. Secure it with the provided mounting screws.
- Instalar placa de parede: Attach the included wall plate over the timer switch.
- Restaurar enerxía: Volve a conectar o interruptor.

Image: Detailed wiring diagram for the timer switch, emphasizing the neutral wire requirement.
Video: An instructional video demonstrating the installation and basic operation of the BN-LINK Countdown Digital In-wall Timer Switch.
Instrucións de funcionamento
The BN-LINK Digital Countdown Wall Timer Switch features intuitive push-button controls for easy operation. Each button has a small LED indicator that illuminates when active.
1. Preset Countdown Functions
The timer offers six preset countdown durations: 5 minutes, 15 minutes, 30 minutes, 60 minutes (1 hour), 2 hours, and 4 hours. To activate a countdown:
- Press the button corresponding to your desired countdown time (e.g., "5 Min", "15 Min", "1 Hour").
- The LED indicator next to the selected button will illuminate, and the connected device (fan/light) will turn on.
- The device will automatically turn off once the countdown period expires.
2. Manual ON/OFF
The "ON/OFF" button allows for continuous operation or immediate shut-off, overriding any active countdown or repeat function.
- Press "ON/OFF" once to turn the connected device on indefinitely. The "ON/OFF" LED will illuminate.
- Press "ON/OFF" again to turn the connected device off immediately. The "ON/OFF" LED will turn off.
3. Función de repetición
The "REPEAT" button activates a daily repeat for the currently selected countdown program.
- While a countdown program is active, press the "REPEAT" button. The "REPEAT" LED will illuminate.
- The selected countdown will automatically run at the same time every day.
- To deactivate the repeat function, press the "REPEAT" button again. The LED will turn off.
- Alternatively, pressing the "ON/OFF" button will also cancel the repeat function.

Imaxe: Máis deview of timer switch features, including LED indicators, one-button programming, repeat function, and manual ON/OFF.

Image: The repeat button on the timer switch, which allows for daily automatic countdowns.
Aplicacións versátiles
This timer switch is suitable for a wide range of indoor applications, enhancing convenience and energy savings in various areas of your home. It is compatible with incandescent, fluorescent, and LED lighting, as well as bathroom exhaust fans and heaters.
- Baños: Automatically turn off exhaust fans after a set period to manage humidity.
- Closets & Pantries: Ensure lights turn off after you leave.
- Garages & Basements: Prevent lights from being left on accidentally.
- Lavandería: Control lighting or fan operation.
- Sauna Rooms: Set specific durations for sauna use.

Imaxe: Examples of various rooms and settings where the timer switch can be effectively utilized.
Resolución de problemas
If you encounter any issues with your BN-LINK Digital Countdown Wall Timer Switch, please review the installation steps and operating instructions carefully. Ensure all wire connections are secure and that the power supply is active. If problems persist, please contact customer support for assistance.
Garantía e Atención ao Cliente
The BN-LINK Digital Countdown Wall Timer Switch is ETL listed, conforming to UL Std. 60730-1 and 60730-2-7, ensuring safety and reliability. For any questions regarding installation, operation, or product support, please do not hesitate to contact BN-LINK customer service. We are committed to providing quality products and support to our customers.
Contact information can typically be found on the product packaging or the official BN-LINK websitio.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.