1. Introdución
This manual provides essential information for the safe and efficient operation of your Victron Energy Centaur 24-Volt 16 amp 3 Bank Battery Charger. The Centaur charger is designed for robust performance, featuring auto-ranging input and three isolated outputs for multi-battery setups. Please read this manual thoroughly before installation and use.
2. Información de seguridade
WARNING: Incorrect installation can be hazardous. Please consult a licensed professional and follow all applicable electrical codes during installation.
- Ensure the charger is installed in a well-ventilated area.
- Avoid exposing the charger to temperatures outside its operating range of -20 to 60°C (0 - 140°F).
- Maintain humidity levels below 95% to prevent damage.
- Do not attempt to open or repair the charger yourself. Refer all servicing to qualified personnel.
- Always disconnect power before making any connections or performing maintenance.
3. Características clave
- Auto-Ranging Input: Covers 90-265VAC 50/60Hz, allowing use worldwide.
- Three Isolated Outputs: Capable of simultaneously charging up to three battery banks, with each output supplying the full rated current.
- Tres-Stage Carga: Features bulk, absorption, and float stages with temperature compensation for optimal battery health.
- Internal Temperature Sense: Ensures power components operate within specified limits, automatically reducing output current under extreme environmental conditions if necessary.
- Construción robusta: Aluminium epoxy powder-coated cases with drip shield and stainless steel fixings provide durability in harsh environments, resisting heat, humidity, and salt air.
- Protección anticorrosiva: Circuit boards are protected with an acrylic coating for maximum corrosion resistance.

Figura 3.1: Máisview of Centaur Charger Features
4. Especificacións
| Especificación | Valor |
|---|---|
| Marca | Victron Energy |
| Número de modelo | CCH024016000 |
| Dimensións do produto (P x A x A) | 4.3" x 8.5" x 14" (110 mm x 214 mm x 351 mm) |
| Peso do elemento | 8.4 libras (3.8 kg) |
| Vol. De saídatage | 24 voltios |
| Vol. De entradatage | 90-265 V CA (50/60 Hz) |
| Valoración actual | 16 Amps |
| Número de Saídas | 3 |
| Tempo de carga da batería | 4 Hours (absorption stage timer) |
| Temperatura de funcionamento | -20 to 60°C (0 - 140°F) |
| Humidade | Máx. 95% (sen condensación) |

Figure 4.1: Centaur Charger Dimensions
5. Configuración e instalación
Installation of the Centaur battery charger should only be performed by a qualified professional in accordance with all local and national electrical codes. Ensure proper ventilation and secure mounting of the unit.
The charger features three isolated outputs. Connect each output to a separate battery bank. The auto-ranging input allows connection to a wide range of AC power sources (90-265VAC, 50/60Hz) without manual adjustment.

Figure 5.1: Connecting to Multiple Battery Banks
6. Instrucións de funcionamento
The Centaur charger employs a sophisticated three-stage charging algorithm to optimize battery charging and prolong battery life:
- Granel Stage: The charger delivers maximum current to rapidly charge the battery until the output current reduces to 70% of the rated Amps.
- Absorción Stage: Unha vez que o groso stage criteria are met, a 4-hour timer begins. During this period, the charger maintains a constant voltage to ensure the battery is fully charged. An internal temperature sensor compensates the charge voltage to prevent overcharging or undercharging based on ambient temperature. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel, or AGM batteries.
- Flotador Stage: Despois da absorción stage timer concludes, the charger switches to a lower float voltage para manter a batería a plena carga sen sobrecargar.
7. Seguimento
7.1. Victron Remote Management (VRM)
The Victron Remote Management (VRM) portal allows you to monitor, manage, and optimize your Victron Energy systems remotely. It helps identify potential issues early by setting alerts and alarms. VRM is free and works with a GX-device (such as the Cerbo GX) with an internet connection or the GlobalLink 520 for smaller systems.
Video 7.1.1: Introduction to Victron Remote Management (VRM) portal, demonstrating how to check remote systems at a glance, manage devices with simple controls, monitor system performance in detail, and design safety nets with programmable alerts and alarms.

Figure 7.1.2: Victron Remote Monitoring (VRM) Interface
7.2. Aplicación VictronConnect
The VictronConnect app allows you to configure, monitor, update, and diagnose your Victron product. It connects to Victron products via Bluetooth, USB, and WiFi/LAN/Internet, providing real-time data and control from your smartphone or tablet.
Video 7.2.1: Demonstration of the VictronConnect App, showing how to instantly check key monitoring data, see device performance, stay on top with simple controls, and perform easy configuration, firmware updating, and commissioning.

Figure 7.2.2: VictronConnect App Interface
8. Mantemento
To ensure optimal performance and longevity of your Centaur battery charger, follow these general maintenance guidelines:
- Regularly inspect the charger and its connections for any signs of damage, corrosion, or loose wiring.
- Manteña o cargador limpo e libre de po e sucidade. Use un pano seco para limpar.
- Asegúrese de que haxa unha ventilación axeitada arredor da unidade para evitar o sobrequecemento.
- Periodically check battery terminals for cleanliness and tightness.
9 Solución de problemas
If you encounter issues with your Centaur charger, consider the following basic troubleshooting steps:
- Sen enerxía: Check the AC input connection and ensure the power source is active. Verify all fuses and circuit breakers.
- No Charging Output: Confirm battery connections are secure and correct polarity is observed. Check if the charger is in a fault state (refer to any indicator lights on the unit).
- Sobrequecemento: Ensure the charger has sufficient ventilation and is not obstructed. Verify ambient temperature is within operating limits.
- Ruídos ou cheiros pouco comúns: Immediately disconnect power and contact qualified service personnel.
For complex issues or if troubleshooting steps do not resolve the problem, contact Victron Energy support or a certified technician.
10. Garantía e soporte
The Victron Energy Centaur 24-Volt 16 amp 3 Bank Battery Charger comes with a 5 ano de garantía. For warranty claims or technical support, please contact your authorized Victron Energy dealer or visit the official Victron Energy websitio web con información de contacto e recursos de apoio.