This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Smith's Environmental Products Quiet-One Kickspace Fan Heater, Model B628330. This unit is designed to provide supplemental heat by circulating hot water from your central heating system through a heat exchanger and distributing the warmth with an integrated fan. Please read all instructions carefully before installation and use.
2. Información de seguridade
WARNING: Failure to follow these safety instructions could result in fire, electric shock, property damage, serious injury, or death.
- Instalación profesional recomendada: Installation of this hot water fan heater requires plumbing and electrical connections. It is strongly recommended that installation be performed by a qualified plumber and a licensed electrician in accordance with all local and national codes.
- Seguridade eléctrica: Ensure the unit is properly grounded. Disconnect power before servicing or performing any maintenance. Do not operate with a damaged cord or plug.
- Seguridade na auga: Ensure all water connections are secure and leak-free. Do not operate if water leakage is detected.
- Colocación: Do not block air intake or exhaust vents. Maintain adequate clearance around the unit for proper airflow.
- Nenos e animais: Keep children and pets away from the unit during operation, as surfaces may become hot.
- Materiais inflamables: Do not store or use flammable materials near the heater.
- Uso previsto: This heater is designed for indoor use only, specifically for heating residential or commercial spaces. Do not use for drying clothes or other unintended purposes.
3. Contido do paquete
Carefully unpack the box and ensure all items are present and undamaged. If any items are missing or damaged, contact your supplier immediately.
- Quiet-One Kickspace Fan Heater Unit (Model B628330)
- Manual de instalación e usuario (este documento)

Image 1: The Smith's Environmental Products Quiet-One Kickspace Fan Heater unit. This image shows the compact design of the heater, featuring a brown casing with a front grille for air output and a top grille for air intake.
4. Especificacións
The following table outlines the key specifications for the Quiet-One Kickspace Fan Heater, Model B628330:
| Característica | Especificación |
|---|---|
| Marca | Smith's Environmental Products |
| Número de modelo | B628330 (KS2008) |
| Saída de calor | 8000 BTU |
| Heat Source Type | Hot Water (from central heating system) |
| Electrical Power (Fan) | 120 V |
| Característica especial | Funcionamento silencioso |
| Cor | marrón |
| Factor de forma | Cabinet / Kickspace |
| Uso interior/exterior | Interior |
| Dimensións do produto (P x A x A) | 10.88" x 13.88" x 3.5" |
| Tipo de montaxe | Floor Mount (Kickspace) |
| Tipo de habitación | Bedroom, Living Room, Kitchen (under cabinet) |
| Peso do elemento | 15 libras |
| Aprobacións | UL, CSA, RTS |

Image 2: The Smith's Environmental Products Quiet-One Kickspace Fan Heater with its key dimensions labeled. The image clearly shows the depth (10.88"), width (13.88"), and height (3.5") of the unit, essential for installation planning.
5. Instalación e configuración
IMPORTANT: Installation must comply with all local and national electrical and plumbing codes. It is highly recommended that a qualified professional perform the installation.
5.1 Selección do sitio
- Choose a location with sufficient space for the unit (refer to dimensions in Section 4) and adequate clearance for air circulation.
- Typically installed in a kickspace under cabinets, stairs, or other confined areas.
- Ensure the location allows for easy access for maintenance and servicing.
5.2 Conexións de fontanería
- This unit connects to your existing hot water heating system.
- Connect the supply and return lines from your heating system to the heater's heat exchanger connections.
- Use appropriate fittings and sealants to ensure watertight connections.
- Bleed air from the system after filling to ensure proper water flow.
5.3 Conexións eléctricas
- The unit requires a 120V electrical supply to power the fan.
- Connect the heater to a dedicated, grounded electrical circuit protected by a fuse or circuit breaker of the appropriate rating.
- Follow all wiring diagrams provided with the unit (if applicable) and adhere to local electrical codes.
- Asegúrese de que todas as conexións estean seguras e illadas.
5.4 Comprobacións finais
- Verify all plumbing connections are free of leaks.
- Confirm all electrical connections are secure and correctly wired.
- Ensure the unit is properly mounted and stable.
- Check that air intake and exhaust grilles are unobstructed.
6. Funcionamento
Once properly installed and connected, operating your Quiet-One Kickspace Fan Heater is straightforward.
- Encendido: Ensure the electrical supply to the unit is switched on.
- Control de termostato: The heater typically operates in conjunction with your central heating system's thermostat. When the room temperature drops below the thermostat setting, the central heating system will circulate hot water to the unit, and the fan will activate to distribute the heat.
- Fan Speed (if applicable): Some models may feature a fan speed switch (e.g., Low/High). Adjust this switch to your desired airflow and noise level. Refer to any specific controls on your unit.
- Apagar: To turn off the heater, simply turn off the central heating system or switch off the electrical supply to the unit.
7. Mantemento
Un mantemento regular garante un rendemento óptimo e unha maior duración do teu quentador.
- Limpeza: Periodically clean the air intake and exhaust grilles to prevent dust and debris buildup, which can restrict airflow and reduce efficiency. Use a soft brush or vacuum cleaner.
- Filter (if applicable): Some models may include an air filter. Check and clean or replace the filter as recommended in specific product documentation.
- Inspección anual: It is advisable to have a qualified technician inspect the unit annually, especially before the heating season, to check for leaks, electrical connections, and overall operational integrity.
- Non lubricar: The fan motor is typically permanently lubricated and does not require additional oiling.
8 Solución de problemas
If you encounter issues with your heater, refer to the following common problems and solutions. If the problem persists, contact a qualified technician.
| Problema | Causa posible | Solución |
|---|---|---|
| Sen saída de calor | No hot water circulating; Thermostat not calling for heat; Air in heating system; Blocked heat exchanger. | Check central heating system and thermostat settings; Bleed air from the heating system; Contact a plumber. |
| O ventilador non funciona | No electrical power; Fan motor failure; Thermostat not calling for heat. | Check circuit breaker/fuse; Ensure unit is plugged in; Verify thermostat setting; Contact an electrician or service technician. |
| Fluxo de aire reducido | Blocked grilles; Dirty filter (if applicable). | Clean grilles; Clean or replace filter. |
| Ruído insólito | Loose components; Fan obstruction; Motor bearing wear. | Inspect for loose parts; Clear any obstructions; Contact a service technician for motor issues. |
| Fuga de auga | Loose plumbing connections; Damaged heat exchanger. | Tighten connections; Immediately shut off water supply and contact a qualified plumber. |
9. Garantía e soporte
For warranty information, please refer to the documentation provided at the time of purchase or visit the official Smith's Environmental Products website. If you require technical assistance, replacement parts, or service, please contact Smith's Environmental Products customer support directly. Ensure you have your model number (B628330) and purchase date available when contacting support.
Información de contacto: Consulte a información oficial do fabricante websitio web ou na documentación da súa compra para obter os datos de contacto máis actuais.