Fein Turbo 2
Fein Turbo II Wet/Dry Vacuum Instruction Manual
Modelo: Turbo 2
1. Introdución
Thank you for choosing the Fein Turbo II Wet/Dry Vacuum. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new dust extractor. Please read this manual thoroughly before using the product and keep it for future reference.

Figure 1: Fein Turbo II Wet/Dry Vacuum
2. Información de seguridade
Observe sempre as seguintes precaucións de seguridade para reducir o risco de incendio, descarga eléctrica ou lesións.
- Le todas as instrucións antes de usar.
- Non deixe o aparello sen vixilancia cando estea enchufado. Desenchufe da toma de corrente cando non estea en uso e antes de realizar o mantemento.
- Non use ao aire libre nin en superficies húmidas.
- Non permita que se use como xoguete. É necesario prestar moita atención cando o usen ou preto dos nenos.
- Use só como se describe neste manual. Empregue só os accesorios recomendados polo fabricante.
- Non o use con cable ou enchufe danados. Se o aparello non funciona como debería, caeu, estrañouse, deixouse ao aire libre ou caeu á auga, devólveo a un centro de servizo.
- Non tire ou transporte co cable, non use o cable como asa, non peche unha porta sobre o cable nin tire do cable por bordos ou esquinas afiadas. Non pase o aparello sobre o cable. Manteña o cable lonxe de superficies quentes.
- Non desconecte tirando do cable. Para desenchufar, agarre o enchufe, non o cable.
- Non manipule o enchufe ou o aparello coas mans molladas.
- Non coloque ningún obxecto nas aberturas. Non use con ningunha abertura bloqueada; manteña libre de po, pelusa, cabelos e calquera cousa que poida reducir o fluxo de aire.
- Manteña o cabelo, a roupa solta, os dedos e todas as partes do corpo lonxe das aberturas e das partes móbiles.
- Non coller nada que arde ou fume, como cigarros, mistos ou cinzas quentes.
- Non o use para recoller líquidos inflamables ou combustibles, como a gasolina, nin o use en áreas onde poidan estar presentes.
- Non recolla materiais tóxicos, amianto ou outros materiais perigosos.
- Teña coidado extra ao limpar as escaleiras.
- Non use sen bolsa de po e/ou filtros colocados.
- Desactiva todos os controis antes de desconectar.
- Anti-Static Functionality: The integrated anti-static system helps prevent electrostatic buildup, reducing risks when working with fine dust and other materials.
3. Que hai na caixa
Your Fein Turbo II Wet/Dry Vacuum package includes the following components:
- Fein Turbo II Wet/Dry Vacuum Unit
- 13-foot Vacuum Hose
- Cable de alimentación de 19 pés
- Side Brushes (as listed in specifications)
- HEPA Filter (pre-installed or included)
- Manual de operación

Figure 2: Included Accessories and Optional Attachments
4. Instrucións de configuración
- Desembalaxe: Retire con coidado todos os compoñentes da embalaxe. Inspeccione se hai algún dano.
- Instalación do filtro: Ensure the HEPA filter is correctly installed. For dry vacuuming, a dust bag is recommended. For wet vacuuming, remove the dust bag.
- Conexión da mangueira: Attach the 13-foot vacuum hose to the inlet port on the front of the unit. Ensure a secure connection.
- Almacenamento de accesorios: The unit features practical accessory storage. Utilize the integrated holders and hooks for convenient organization of the hose, power cord, and other attachments.
- Conexión de alimentación: Conecta o cable de alimentación de 19 pés a unha toma de corrente axeitada.

Figure 3: Practical Accessory Storage
Video 1: Fein Wet and Dry Dust Extractors and Accessories - This video demonstrates the setup and features of Fein dust extractors, including hose connection and accessory use.
5. Instrucións de funcionamento
5.1. Acendido/apagado
To turn the unit on, rotate the control knob to the 'I' position. To turn off, rotate to the '0' position.
5.2. Aspiración en seco
For dry debris, ensure the dust bag is installed and the HEPA filter is clean. Attach the appropriate nozzle to the hose and begin vacuuming. The 1,100-watt motor delivers 151 CFM airflow for efficient dust removal.
5.3. Aspiración húmida
For liquid spills, remove the dust bag. Ensure the HEPA filter is suitable for wet use or replaced with a wet filter if necessary. Attach the appropriate wet nozzle and vacuum liquids. The unit provides 98 PSI static water lift for effective liquid extraction.
5.4. Integrated Autostart for Power Tools
The unit features an autostart outlet. Plug your power tool into this outlet. When the power tool is activated, the vacuum will automatically turn on with a slight delay to prevent current overload. This feature improves workflow efficiency and ensures continuous dust extraction during tool operation.
5.5. Funcionamento silencioso
The Fein Turbo II operates at a low noise level of 66 dB(A), making it suitable for noise-sensitive environments without compromising suction power.

Figure 4: Using the vacuum with a power tool for dust extraction
Video 2: Noise Test of Fein Turbo 1 HEPA Dust Extractor - Demonstrates the low noise level during operation.
Video 3: Great for all Types of Messes - Shows the versatility of the vacuum for various cleaning tasks.
6. Mantemento
6.1. Limpeza e substitución do filtro
Regularly check the HEPA filter for dust buildup. For optimal performance, clean or replace the filter as needed. Refer to the filter manufacturer's instructions for specific cleaning procedures. Always use genuine Fein replacement filters.
6.2. Substitución da bolsa de po
When the dust bag is full, replace it with a new one. Ensure the new bag is properly seated to prevent dust leakage.
6.3. Limpeza xeral
Limpa o exterior da unidade con anuncioamp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure all components are dry before storage.
7 Solución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| Sen poder | Unit unplugged; circuit breaker tripped | Check power cord connection; reset circuit breaker |
| Baixa succión | Clogged hose/nozzle; full dust bag; dirty filter | Clear obstruction; replace dust bag; clean/replace filter |
| Po escapando | Improperly installed filter/dust bag; damaged filter/bag | Reinstall filter/bag correctly; replace damaged components |
| Unit does not start with power tool (Autostart) | Power tool not plugged into autostart outlet; autostart switch not engaged | Ensure power tool is correctly plugged in; check autostart switch setting |
8. Especificacións
- Marca: Fein
- Nome do modelo: Turbo 2
- Capacidade: 10 Gallons (8.5 Gallon variant also available)
- Potencia do motor: 1.477 horsepower (Max 1.48 HP)
- Ampera: 9.17 Amps
- Aspiración máxima: 151 CFM Airflow, 98 PSI Static Water Lift
- Nivel de ruído: 66 decibeis (dB)
- Lonxitude da mangueira: 13 pés
- Lonxitude do cable de alimentación: 19 pés
- Tipo de filtro: Filtro HEPA
- Característica especial: Bag, Anti-Static System, Autostart Outlet
- Dimensións do produto: 10 cm de longo x 10 cm de ancho x 10 cm de alto
- Peso do artigo: 25 libras
- Cor: Laranxa
- Fonte de enerxía: Eléctrico con cable
- Usos recomendados: Garage, Construction Sites, Workshops, Hard Floor, Carpet

Figura 5: Características e especificacións principais
9. Garantía
For detailed warranty information, please refer to the official documentation included with your product or visit the official Fein websitio. Os plans de protección poden estar dispoñibles para a súa compra por separado.
10. Apoio
If you require further assistance, have questions about your Fein Turbo II Wet/Dry Vacuum, or need to order replacement parts, please visit the official Fein websitio web ou póñase en contacto co servizo de atención ao cliente. Pode atopar máis información en Tenda Fein en Amazon.
Video 4: Is it worth it? Fein Turbo I Wet/Dry Dust Extractor - A user review highlighting features and performance.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.