Read and understand this entire manual before operating the generator. Failure to follow instructions can result in serious injury or death.
- Risco de monóxido de carbono: Generators produce carbon monoxide, a colorless, odorless, poisonous gas. Operate the generator outdoors in a well-ventilated area, far from windows, doors, and vents. Never operate indoors or in enclosed spaces.
- Seguridade eléctrica: Never operate the generator in wet conditions. Ensure all electrical connections are secure and properly grounded. Do not overload the generator.
- Seguridade de combustible: Gasoline is highly flammable. Always refuel in a well-ventilated area with the engine off and cool. Do not smoke or allow open flames near the generator. Store fuel in an approved container.
- Funcionamento xeral: Keep children and pets away from the generator during operation. Wear appropriate personal protective equipment (PPE). Ensure the generator is placed on a level surface.
2. Produto rematadoview
The Clarke IG3500AF is a powerful and portable inverter generator designed to provide clean and stable electricity for various applications. Its advanced technology ensures a near-pure sine wave output, making it safe for sensitive electronics.

Figure 1: Clarke IG3500AF Inverter Generator
Características principais:
- Motor: 212cc 4-stroke engine.
- Potencia de saída: 3.4kW Max AC output, 3.2kW continuous rated power.
- Puntos de venda: 2 x 230V AC outlets, 1 x 12V/8A DC outlet.
- Forma de onda: Near-pure sine wave AC output (THD ≤ 3%) for sensitive electronics.
- Sistema de arranque: Inicio de retroceso.
- Tempo de execución: Approximately 8 hours at 75% load on a full tank.
- Capacidade de combustible: 13 litros.
- Eficiencia de combustible: ECO throttle system to minimize fuel consumption and noise.
- Dimensións: 555 x 465 x 495 mm.
- Peso: 35 kg.
- Nivel de ruído: 96 dB(A).
3. Guía de configuración
3.1 Desembalaxe
- Retire con coidado o xerador da súa embalaxe.
- Inspeccione se hai algún dano durante o envío. Póñase en contacto co seu distribuidor inmediatamente se atopa danos.
- Asegúrese de que todos os compoñentes incluídos estean presentes.
3.2 Engadir aceite de motor
The generator is shipped without engine oil. Operating without oil will cause severe engine damage.
- Coloque o xerador nunha superficie plana.
- Localice a tapa/varilla de nivel de aceite.
- Retire a vara de medición e limpa.
- Add recommended engine oil (e.g., SAE 10W-30) to the crankcase until the oil level reaches the upper mark on the dipstick. Do not overfill.
- Volva colocar a tapa/varilla de nivel de aceite de forma segura.
3.3 Engadir combustible
Use só gasolina nova sen chumbo cunha clasificación de octanaxe de 87 ou superior.
- Ensure the generator is turned OFF and has cooled down.
- Move the generator to a well-ventilated outdoor area for refueling.
- Desenrosque a tapa do combustible.
- Carefully pour gasoline into the fuel tank, up to the fill limit (approximately 13 liters). Do not overfill.
- Securely replace the fuel cap. Wipe up any spilled fuel immediately.
4. Instrucións de funcionamento
4.1 Starting the Generator (Recoil Start)
- Asegúrese de que o xerador estea sobre unha superficie nivelada e de que todas as cargas eléctricas estean desconectadas.
- Xire a válvula de combustible á posición "ON".
- Mova a panca do estrangulador á posición "ESTRANGUADOR" (se o motor está frío).
- Xire a chave do motor á posición "ON".
- Grasp the recoil starter handle firmly and pull it slowly until resistance is felt, then pull quickly and smoothly. Repeat until the engine starts.
- Once the engine starts, slowly move the choke lever to the 'RUN' position.
- Deixe que o motor se quente uns minutos antes de conectar as cargas eléctricas.
4.2 Parar o xerador
- Desconecte todas as cargas eléctricas do xerador.
- Deixe que o xerador funcione durante uns minutos sen carga para que arrefríe.
- Xire o interruptor do motor á posición "OFF".
- Xire a válvula de combustible á posición "OFF".
4.3 Conexión de dispositivos eléctricos
- Ensure the generator is running stably before connecting devices.
- Plug your 230V AC devices into the AC outlets.
- For 12V DC charging, connect your device to the 12V DC outlet.
- Do not exceed the generator's rated power output (3.2kW continuous, 3.4kW max).
4.4 ECO Throttle System
The ECO throttle system automatically adjusts engine speed to match the load, reducing fuel consumption and noise levels. For maximum power or when starting high-load devices, it may be necessary to switch the ECO throttle OFF.
4.5 Protección contra sobrecarga
The generator is equipped with an overload protection system. If the generator is overloaded, the circuit breaker will trip, and power output will stop. Reduce the load and reset the circuit breaker to restore power.
5. Mantemento
Regular maintenance is crucial for the longevity and reliable operation of your generator. Always turn off the engine and allow it to cool before performing any maintenance.
5.1 Regular Checks (Before Each Use)
- Comprobar o nivel de aceite do motor.
- Comprobar o nivel de combustible.
- Inspect for any loose fasteners or damaged components.
5.2 Filtro de aire
Clean the air filter every 50 hours of operation or more frequently in dusty conditions. Replace if damaged.
- Retire a tapa do filtro de aire.
- Retire o elemento do filtro de escuma.
- Wash the element in warm, soapy water, rinse, and allow to air dry completely.
- Lightly oil the foam element with engine oil, then squeeze out excess oil.
- Reinstall the filter element and cover.
5.3 Bujía
Inspect the spark plug every 100 hours of operation. Replace if necessary.
- Retire a tapa da bujía.
- Use unha chave para bujías para extraer a bujía.
- Check for carbon deposits or wear. Clean with a wire brush if needed.
- Check the spark plug gap (refer to specifications for correct gap).
- Reinstale a bujía e a tapa.
5.4 Filtro de combustible
Inspect the fuel filter periodically and replace if clogged or damaged. Refer to the service manual for detailed instructions.
5.5 Almacenamento
For extended storage (more than 30 days):
- Drene o depósito de combustible e o carburador.
- Add a fuel stabilizer if draining is not possible.
- Cambiar o aceite do motor.
- Clean the generator thoroughly.
- Gardar nun lugar limpo, seco e ben ventilado.
6 Solución de problemas
This section provides solutions to common operational problems. For issues not listed here, contact customer support.
| Problema | Causa posible | Solución |
|---|---|---|
| O motor non arrancará | Sen combustible Baixo nivel de aceite Interruptor do motor OFF Estrangulamento incorrecto Spark plug faulty | Engade combustible Engadir aceite Acende o interruptor do motor Axustar o estrangulador Limpar/substituír a bujía |
| Sen saída de enerxía | Sobrecarga O interruptor automático disparou Conexións soltas | Reducir a carga Restablecer o interruptor automático Comproba e protexe as conexións |
| O motor para durante o funcionamento | Sen combustible Baixo nivel de aceite Sobrecarga | Engade combustible Engadir aceite Reducir a carga |
7. Especificacións técnicas
| Especificación | Valor |
|---|---|
| Marca | Clarke |
| Número de modelo | 8877125 (IG3500AF) |
| Tipo de motor | 212cc 4-stroke |
| Fonte de enerxía | Fuel (Petrol) |
| Potencia máxima de saída | 3400 Watt (3.4 kW) |
| Potencia nominal continua | 3200 Watt (3.2 kW) |
| Voltage | 230 Volt AC, 12 Volt DC |
| Tipo de combustible | Gasolina |
| Capacidade do depósito de combustible | 13 litros |
| Tempo de execución (75 % de carga) | 8 horas |
| Características especiais | Portable, ECO Throttle, Pure Sine Wave |
| Compoñentes incluídos | Arrancador de retroceso |
| Cor | Negro |
| Dimensións (L x W x H) | 555 x 465 x 495 mm |
| Peso | 35 kg |
| Nivel de son | 96 dB(A) |
8. Garantía e atención ao cliente
Warranty information for the Clarke IG3500AF Inverter Generator is typically provided at the time of purchase or included with the product documentation. Please refer to your purchase receipt or the warranty card for specific terms and conditions.
For technical assistance, spare parts, or warranty claims, please contact your authorized Clarke dealer or the manufacturer's customer support directly. Ensure you have your model number (IG3500AF) and serial number ready when contacting support.