POOLEX PC-QBC070

Manual do usuario da bomba de calor para piscina POOLEX PC-QBC070 Q-Line 7 Full Inverter

1. Introdución

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POOLEX PC-QBC070 Q-Line 7 Full Inverter Pool Heat Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.

The POOLEX Q-Line 7 heat pump is designed for heating swimming pools with a volume of 20 to 50 cubic meters. It incorporates Full Inverter technology, vertical air discharge, and integrated Wi-Fi for enhanced control and energy efficiency.

2. Información de seguridade

  • Asegúrese de que todas as conexións eléctricas sexan realizadas por un electricista cualificado e de que cumpra a normativa local.
  • Do not operate the heat pump if any part is damaged or if it is not functioning correctly.
  • Manteña os nenos e o persoal non autorizado lonxe da unidade durante o funcionamento.
  • Ensure proper ventilation around the unit. Do not obstruct the air intake or discharge areas.
  • Desconecte sempre a alimentación antes de realizar calquera mantemento ou servizo.
  • Este aparello non está pensado para o seu uso por persoas (incluídos nenos) con capacidades físicas, sensoriais ou mentais reducidas, ou con falta de experiencia e coñecementos, a menos que teñan supervisión ou instrucións sobre o uso do aparello por unha persoa responsable da súa seguridade.

3. Contido do paquete

Ao desembalar, comprobe que todos os compoñentes estean presentes e sen danos:

  • POOLEX PC-QBC070 Q-Line 7 Full Inverter Pool Heat Pump
  • Manual de usuario
  • Connection accessories (e.g., water pipe connectors, seals)
  • Mangueira de drenaxe

4. Produto rematadoview

The POOLEX PC-QBC070 Q-Line 7 heat pump features a compact design with vertical air discharge, optimizing space utilization. Its Full Inverter technology precisely controls the compressor and fan speed, leading to significant energy savings. The unit includes an integrated Wi-Fi module for remote control via a smartphone application and front-facing LED indicators for operational status.

POOLEX PC-QBC070 Q-Line 7 Full Inverter Pool Heat Pump

Figura 4.1: Fronte e lateral view of the POOLEX PC-QBC070 Q-Line 7 Pool Heat Pump.

POOLEX PC-QBC070 Control Panel

Imaxe 4.2: Primeiro plano view of the control panel and LED indicators on the POOLEX PC-QBC070.

POOLEX PC-QBC070 Airflow Diagram

Figure 4.3: Diagram illustrating the vertical airflow pattern of the heat pump, with air intake (red arrows) and vertical discharge (blue arrows).

POOLEX PC-QBC070 Dimensions

Figure 4.4: Dimensions of the POOLEX PC-QBC070 heat pump, showing its compact cubic form (36.04 cm x 36.04 cm x 36.04 cm).

5. Configuración e instalación

5.1 Colocación

  • Due to its vertical air discharge, the Q-Line 7 can be installed in more confined technical spaces compared to traditional horizontal discharge units.
  • Ensure there is adequate clearance around the unit for proper airflow and maintenance access. Refer to the manufacturer's recommended clearances.
  • Install the unit on a stable, level surface capable of supporting its weight (43 kg).

5.2 Conexións de auga

  • Connect the heat pump to your pool's filtration system after the filter and before any chemical injection points.
  • Ensure all connections are watertight using appropriate seals and clamps.
  • The heat pump requires a continuous flow of water from the pool pump to operate.

5.3 Conexións eléctricas

  • The unit operates on 230 Volts. Ensure the power supply matches the unit's requirements.
  • A dedicated circuit with appropriate overcurrent protection (circuit breaker) is recommended.
  • Toda a fiação eléctrica debe cumprir cos códigos eléctricos nacionais e locais.

5.4 Configuración Wi-Fi

  • Download the dedicated POOLEX smartphone application from your device's app store.
  • Follow the in-app instructions to connect your heat pump to your home Wi-Fi network. This typically involves putting the unit into pairing mode and entering your network credentials.

6. Instrucións de funcionamento

6.1 Acendido/Apagado

  • Ensure the pool pump is running and water is flowing through the heat pump before powering on.
  • Prema o botón de acendido no panel de control para acender ou apagar a unidade.

6.2 Setting Desired Temperature

  • Use the up/down arrows on the control panel to adjust the target water temperature.
  • The heat pump will automatically operate to reach and maintain the set temperature.

6.3 Indicadores LED

The front-facing LED indicators provide visual feedback on the unit's status:

  • Different color codes indicate whether the target temperature has been reached, if the unit is heating, or if there is an operational status change. Refer to the specific color code legend in the full manual for detailed interpretation.

6.4 Smartphone Control (Wi-Fi)

  • Once connected via Wi-Fi, use the POOLEX application on your smartphone to monitor and control the heat pump remotely.
  • Functions typically include turning the unit on/off, adjusting temperature, setting timers, and viewing operational data.

7. Mantemento

7.1 Limpeza regular

  • Periodically clean the exterior of the unit to remove dust and debris.
  • Ensure the air intake and discharge grilles are free from obstructions (leaves, dirt, etc.) to maintain optimal airflow.
  • Clean the evaporator coils if they become dirty, using a soft brush or compressed air.

7.2 Mantemento do sistema de auga

  • Regularly check water connections for leaks.
  • Ensure the pool's water chemistry is balanced to prevent corrosion or scaling within the heat pump.

7.3 Invernización

  • Before freezing temperatures, drain all water from the heat pump to prevent damage from ice expansion.
  • Disconnect the water lines and open any drain plugs.
  • Cover the unit with a protective, breathable cover to shield it from harsh weather conditions.

8 Solución de problemas

This section provides solutions to common issues. For more complex problems, contact qualified service personnel.

ProblemaCausa posibleSolución
A bomba de calor non se acendeNo power supply; Circuit breaker tripped; Unit switch offCheck power connection; Reset circuit breaker; Turn unit on via control panel
Calefacción insuficienteLow water flow; Dirty evaporator coils; Incorrect temperature setting; Ambient temperature too lowCheck pool pump and filter; Clean coils; Adjust temperature; Heat pump efficiency decreases in very cold weather
Unidade que fai ruído inusualLoose components; Fan obstruction; Compressor issueInspect for loose parts; Clear fan area; Contact service if noise persists
Problemas de conexión wifiIncorrect network credentials; Router too far; Signal interferenceRe-enter Wi-Fi details; Move router closer or use extender; Check for interference sources

9. Especificacións

  • Modelo: PC-QBC070
  • Marca: Poolex
  • Dimensións (L x W x H): 36.04 x 36.04 x 36.04 cm
  • Peso: 43 kg
  • Material: Stainless Steel (internal components), ABS (casing)
  • Voltage: 230 voltios
  • Volume da piscina recomendado: 20 m3 a 50 m3
  • Tecnoloxía: Full Inverter, Vertical Air Discharge
  • Conectividade: Integrated Wi-Fi Module

10. Garantía e soporte

The POOLEX PC-QBC070 Q-Line 7 Full Inverter Pool Heat Pump comes with a 2 ano de garantía desde a data de compra, cubrindo defectos de fabricación. Conserve o comprobante de compra para reclamacións de garantía.

For technical support, service, or warranty inquiries, please contact your authorized POOLEX dealer or the customer service department. Provide your model number (PC-QBC070) and a detailed description of the issue when seeking assistance.

Documentos relacionados - PC-QBC070

Preview Bomba de calor Poolex: seguridade, instalación e manual de usuario
Ficha de datos de seguridade completa, guía de instalación e manual de usuario para as bombas de calor para piscinas Poolex, que abarcan o funcionamento seguro, o mantemento e a resolución de problemas.
Preview Poolex Q-Line Heat Pump Installation and User Manual
Comprehensive installation and user manual for the Poolex Q-Line series heat pumps (models 50, 70, 90). Includes safety warnings, technical specifications, installation guides, and maintenance procedures.
Preview Manuel de configuration et d'utilisation pour WiFi intégré Poolex
Ce manuel fournit des instructions détaillées pour la configuration et l'utilisation du contrôle WiFi intégré de votre pompe à chaleur Poolex, vous permettant de gérer votre appareil à distance via l'application Smart Life.
Preview Poolex Silverline ON/OFF Heat Pump - Technical Specifications
Técnico rematadoview and specifications for the Poolex Silverline ON/OFF pool heat pump. Features include Wi-Fi connectivity, titanium heat exchanger, and reversible heating/cooling.
Preview Manual de instalación e usuario da bomba de calor Poolex O'SPA
Manual completo de instalación e usuario da bomba de calor Poolex O'SPA. Obtén información sobre a instalación, o funcionamento, o mantemento e a resolución de problemas seguros do sistema de calefacción da túa piscina ou spa.
Preview Poolex Silverline Fi Full Inverter Warmtepomp - Overzicht en Specificaties
Ontdek de Poolex Silverline Fi, een stille, krachtige en energiezuinige Full Inverter warmtepomp voor zwembaden. Verkrijgbaar in diverse vermogens voor zwembaden tot 150 m³. Met Wi-Fi bediening, verwarmings- en koelfunctie en hoge COP.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.