CAS CL3000-30KG-P
CAS CL3000-P Barcode Label Printing Scale User Manual
Model: CL3000-30KG-P
1. Introdución
This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of the CAS CL3000-P Networking Barcode Label Printing Scale. This device is designed for commercial use in environments such as grocery stores, butcher shops, and supermarkets, offering integrated weighing, price computing, and barcode label printing capabilities.
Características principais:
- Integrated Barcode Label Printer for item-specific labels.
- Networking Ready (LAN) for central price updates and data synchronization.
- High-Speed Printing with 202 dpi resolution.
- Dual LCD Display for operator and customer viewing.
- User-Friendly PLU Management, storing up to 10,000 PLUs.
- Durable Aluminum Body Construction.
2. Desembalaxe e configuración
Desembale coidadosamente todos os compoñentes e asegúrese de que estean presentes todos os elementos antes de continuar coa configuración.
2.1. Contido do paquete
Verifique que os seguintes elementos estean incluídos no seu paquete:
- CAS CL3000-P Scale Unit
- Cable de alimentación
- Label Roll Starter Pack
- Manual de usuario (este documento)
2.2 Colocación
Place the scale on a stable, level surface, away from direct sunlight, excessive heat, or strong vibrations. Ensure adequate space for operation and label printing.
2.3. Conexión de alimentación
- Connect the power cable to the scale's power input port.
- Conecte o outro extremo do cable de alimentación a unha toma de corrente con conexión a terra.
- Turn on the scale using the power switch, typically located on the rear or side of the unit.
2.4. Network Connection (LAN)
For networking capabilities, connect an Ethernet cable from the scale's LAN port to your network router or switch. Refer to your network administrator for specific IP address configuration if required.
2.5. Label Roll Installation
Open the printer cover and carefully load the label roll according to the diagram inside the printer compartment. Ensure the labels feed smoothly and are correctly aligned for printing.
Figure 2.1: CAS CL3000-P Barcode Label Printing Scale with dual display and integrated printer.
3. Instrucións de funcionamento
This section details the basic operation of the CAS CL3000-P scale for weighing, price computing, and label printing.
3.1. Pesaxe básica
- Ensure the scale displays "0.000 kg" before placing any item. If not, press the CERO botón.
- Place the item to be weighed on the weighing platter.
- The weight will be displayed on both the operator and customer LCD screens.
3.2. Price Computing and Label Printing
The scale supports up to 10,000 PLUs (Price Look-Up units) for efficient operation.
- Place the item on the weighing platter.
- Enter the PLU code for the item using the numeric keypad.
- Alternatively, if a PLU is not set, enter the unit price directly using the numeric keypad.
- Preme o IMPRIMIR button to generate a barcode label. The label will include weight, unit price, total price, and barcode.
Figure 3.1: Close-up of the dual LCD display, featuring a scrolling message bar for enhanced communication.
Figure 3.2: Detail of the integrated printer, capable of linerless printing for efficiency.
3.3. PLU Management
The CL3000-P allows for easy management of up to 10,000 PLUs. Refer to the detailed programming guide (separate document or advanced settings menu) for adding, editing, or deleting PLUs.
Figure 3.3: The scale's internal memory supports storage for up to 10,000 product PLUs.
4. Mantemento
Regular maintenance ensures the longevity and accuracy of your CAS CL3000-P scale.
4.1. Limpeza
- Desconecte a alimentación antes de limpar.
- Wipe the scale's exterior and weighing platter with a soft, damp pano.
- Do not use abrasive cleaners, solvents, or immerse the unit in water.
- Ensure no liquids enter the display or printer openings.
4.2. Mantemento da impresora
- Regularly check the printer head for debris or adhesive residue. Clean gently with a lint-free cloth and isopropyl alcohol if necessary.
- Ensure label rolls are stored in a cool, dry place to prevent adhesive degradation.
4.3. Calibración
The scale is factory-calibrated. If you suspect accuracy issues, contact authorized CAS service personnel for re-calibration. Do not attempt to calibrate the scale yourself unless specifically instructed by a qualified technician.
5 Solución de problemas
This section provides solutions to common issues you might encounter with your CAS CL3000-P scale.
| Problema | Causa posible | Solución |
|---|---|---|
| A báscula non se acende. | Power cable disconnected; Power outlet faulty; Power switch off. | Check power cable connection; Test power outlet; Ensure power switch is ON. |
| Lecturas de peso inexactas. | Scale not level; Debris under platter; Needs calibration. | Ensure scale is on a level surface; Clean under platter; Contact service for calibration. |
| Labels not printing or printing blank. | Label roll empty or incorrectly loaded; Printer head dirty; Printer error. | Replace/re-load label roll correctly; Clean printer head; Restart scale. |
| Problemas de conexión á rede. | Ethernet cable disconnected; Network configuration error. | Check Ethernet cable; Verify network settings with IT support. |
If the problem persists after attempting these solutions, please contact CAS customer support.
6. Especificacións
| Característica | Detalle |
|---|---|
| Modelo | CL3000-30KG-P |
| Marca | CAS |
| Límite de peso | 30 quilogramos |
| Precisión de lectura | 10 g |
| Tamaño da pan | 380x250mm (15x10 inches) |
| Tipo de visualización | LCD (Dual Display) |
| PLU Memory | Up to 10,000 PLUs |
| Resolución de impresora | 202 ppp |
| Conectividade | LAN (Ethernet), USB port, RS-232C, RJ11, optional wireless |
| Material | Stainless Steel (platter), Aluminum Body Construction |
| Fonte de enerxía | AC/DC |
| Peso do elemento | 3.5 kg |
| Dimensións do paquete | 30 x 20 x 10 cm |
| País de Orixe | India |
7. Garantía e soporte
7.1. Información da garantía
The CAS CL3000-P scale comes with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact CAS customer service. Extended warranty options may be available.
7.2. Atención ao cliente
For technical assistance, service requests, or any inquiries regarding your CAS CL3000-P scale, please contact CAS Weighing India Pvt Ltd. Their contact information can typically be found on the product packaging or their official websitio.
Información de contacto:
- Manufacturer: CAS Corportaion
- Packer: CAS Weighing India Pvt Ltd
- Importer: CAS Corportation
- Teléfono: 9212559707
Documentos relacionados - CL3000-30KG-P
![]() |
CAS CL3000 Series Label Printing Scale Owner's Manual This manual provides comprehensive instructions for the CAS CL3000 Series Label Printing Scale, covering general information, programming, sales operations, and specifications. Learn how to set up, operate, and maintain your scale for optimal performance. |
![]() |
CAS CN1 Label Printing Scale Quick Guide A quick guide for operating the CAS CN1 label printing scale, covering labelling operations for weighing items and counting items. |
![]() |
CAS PR-II Series Price Computing Scale Owner's Manual Comprehensive owner's manual for the CAS PR-II Series price computing scale, covering installation, operation, maintenance, specifications, and interface details. |
![]() |
CAS CL-5500 Ticket and Label Printing Scale Quick Guide A quick guide to operating the CAS CL-5500 Ticket and Label Printing Scale, covering sales and labeling operations. |
![]() |
Guía de axuste e separación das etiquetas CAS CL5200/CL5500/CL7200 Unha guía completa para axustar a separación entre etiquetas, a calibración do sensor e a lonxitude de preimpresión para as básculas de impresión de etiquetas CAS CL5200, CL5500 e CL7200. |
![]() |
CAS ER JR Series Price Computing Scale Owner's Manual Comprehensive owner's manual for the CAS ER JR Series Price Computing Scale, detailing operation, setup, features, error handling, and technical specifications for retail environments. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.





