Acogedor Acogedor8n2pavgf7h-11

Acogedor 30W 4000RPM DC Electric Concrete Vibration Motor

Model: Acogedor8n2pavgf7h-11

1. Introdución

This manual provides essential information for the safe and effective use of your Acogedor 30W 4000RPM DC Electric Concrete Vibration Motor. Please read these instructions carefully before installation, operation, or maintenance to ensure proper function and prevent damage or injury. Keep this manual for future reference.

2. Información de seguridade

Observe sempre as seguintes precaucións de seguridade para reducir o risco de lesións ou danos:

  • Asegúrate de que a fonte de alimentación coincida co volume do motortage requirements (DC12V).
  • Disconnect power before performing any installation, wiring, or maintenance.
  • Wear appropriate personal protective equipment, including eye protection, when operating the motor.
  • Do not operate the motor in wet conditions or expose it to excessive moisture, as it is rated IP65 for dust and water jet protection, but not submersion.
  • Mount the motor securely to a stable surface to prevent movement during operation.
  • Manteña as mans e a roupa solta lonxe das pezas móbiles.
  • Do not modify the motor or its components. Use only original replacement parts if necessary.

3. Produto rematadoview

The Acogedor DC Electric Concrete Vibration Motor is designed for various applications requiring vibration, such as shaker tables in mining, metallurgy, construction, and food processing. It features a brushless design for efficiency and durability, an aluminum alloy casing, and an adjustable exciting force via an eccentric block.

Acogedor DC Electric Concrete Vibration Motor with dimensions

Figura 3.1: global view of the Acogedor DC Electric Concrete Vibration Motor with key dimensions.

Características principais:

  • Motor DC sen escobillas: Provides strong power, high efficiency, and low noise operation.
  • Carcasa de aliaxe de aluminio: Ensures durability and wear resistance.
  • Clasificación IP65: Offers protection against dust ingress and low-pressure water jets.
  • Adjustable Exciting Force: The eccentric block angle can be adjusted to vary the vibration intensity.
  • Integrated Speed Controller: Allows for precise control over the motor's RPM.
Acogedor DC Electric Concrete Vibration Motor and speed controller highlighting features

Figure 3.2: The vibration motor and its speed controller, illustrating key operational characteristics.

4. Especificacións

ParámetroValor
Tipo de elementoElectric Vibrating Motor
MaterialAluminum alloy, red copper
Vibration ForceAprox. 20 kg / 44.1 lb
Frecuencia50 Hz
Velocidade máxima4000 RPM
ClaseIP65
Voltage12 voltios DC
Poder30 vatios
ModeloAcogedor8n2pavgf7h-11
Close-up of the motor's specification label

Figure 4.1: Motor label showing detailed specifications.

5. Configuración

5.1 Montaxe

The vibration motor must be securely mounted to the application surface (e.g., shaker table) using appropriate fasteners through the mounting holes on its base. Ensure the mounting surface is robust enough to withstand continuous vibration.

5.2 Cableado

The motor comes with a speed controller for easy integration. Follow these steps for wiring:

  1. Asegúrese de que a fonte de enerxía estea desconectada.
  2. Connect the motor's cable to the output terminal of the speed controller.
  3. Connect the input wires of the speed controller to your DC12V power supply. Observe correct polarity (red wire for positive, black wire for negative).
  4. Verifique que todas as conexións estean seguras e illadas correctamente.
Wiring diagram for the Acogedor DC Electric Concrete Vibration Motor and speed controller

Figure 5.1: Illustration of the motor and speed controller wiring connections.

6. Instrucións de funcionamento

6.1 Acendido

Once the motor is securely mounted and wired, connect the DC12V power supply. The motor will be in a standby state or begin operating at the lowest speed setting, depending on the controller's initial position.

6.2 Adjusting Speed and Vibration Force

Use the rotary knob on the speed controller to adjust the motor's RPM from 0 to 4000RPM. Turning the knob clockwise typically increases the speed and vibration force, while turning it counter-clockwise decreases it. Start with a low setting and gradually increase to the desired intensity for your application.

6.3 Apagado

To turn off the motor, rotate the speed controller knob to its minimum setting or disconnect the power supply.

6.4 Adjusting Eccentric Block (Vibration Force)

The vibration force can be further adjusted by changing the angle of the eccentric blocks on the motor. This typically involves loosening fasteners, rotating the eccentric weights to a new position, and then re-tightening the fasteners. Refer to the motor's specific design for detailed instructions on this adjustment, if applicable.

7. Mantemento

Regular maintenance ensures optimal performance and extends the lifespan of your vibration motor.

  • Limpeza: Periodically clean the motor's exterior to remove dust, dirt, and debris. Use a dry cloth or soft brush. Do not use harsh chemicals or immerse the motor in liquids.
  • Inspección: Regularly inspect the motor for any signs of wear, damage, or loose connections. Check the mounting bolts for tightness.
  • Integridade do cable: Ensure the power cable and controller connections are free from cuts, abrasions, or damage.
  • Almacenamento: When not in use, store the motor in a dry, clean environment, away from extreme temperatures and corrosive substances.

8 Solución de problemas

ProblemaCausa posibleSolución
O motor non arrancaNo power supply; Incorrect wiring; Faulty speed controller; Motor damageCheck power connection; Verify wiring polarity; Test speed controller; Contact support
Weak or inconsistent vibrationLow speed setting; Loose mounting; Incorrect eccentric block adjustment; Insufficient powerIncrease speed via controller; Tighten mounting bolts; Adjust eccentric blocks; Check power supply voltage
Sobrequecemento do motorOverload; Insufficient ventilation; Prolonged continuous operationReduce load; Ensure adequate airflow around motor; Allow motor to cool down periodically
Ruído inusual durante o funcionamentoLoose components; Internal damage; Bearing wearCheck for loose parts and tighten; Discontinue use and contact support if noise persists

9. Garantía e soporte

Acogedor products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official Acogedor website. Please have your model number (Acogedor8n2pavgf7h-11) and purchase details ready when contacting support.

Para obter máis información, pode visitar o Acogedor Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.