WZRELB SPVC10K24V

WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter

Model: SPVC10K24V User Manual

1. Introdución

This manual provides essential information for the safe and efficient operation of your WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Instrucións de seguridade

  • Le todas as instrucións: Before operating the inverter, read all instructions and cautionary markings on the inverter, the batteries, and all appropriate sections of this manual.
  • Persoal cualificado: A instalación e o mantemento só deben ser realizados por persoal cualificado.
  • Ventilación: Ensure adequate ventilation around the inverter. Do not install in a zero-clearance compartment.
  • Evitar a humidade: Do not expose the inverter to rain, snow, spray, or bilge water.
  • Proper Battery Connection: Connect the inverter to a 24V battery system only. Incorrect voltagPodemos danar o inversor.
  • Conexión a terra: Ensure the inverter is properly grounded to prevent electrical shock.
  • Desconexión de emerxencia: Know how to quickly disconnect power in an emergency.

3. Contido do paquete

Ao abrir o paquete, comprobe que todos os compoñentes estean presentes e sen danos:

  • WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter
  • DC Connection Cables (AWG5 cables, typically 2 black for negative, 2 red for positive)
  • Fusibles
  • Manual de usuario

Vídeo: Desempaquetado e máisview of the WZRELB Pure Sine Wave Inverter, showing included cables and manual. Note: Video title mentions 6000W, but content is relevant to general inverter features and setup.

4. Produto rematadoview

The WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter converts 24V DC battery power to 120V/240V AC power. It features a high efficiency design, an LCD display for monitoring, and multiple protection functions.

4.1. Front Panel (AC Output)

Front panel of WZRELB 10000W inverter showing multiple AC outlets and hardwire terminals

Imaxe: Front panel of the inverter with two 120V AC outlets and hardwire terminals for 120V and 240V output.

  • 120VAC Outlets: Two standard 120V AC outlets, each supporting up to 5000W.
  • 240VAC Hardwire Terminal (3-wire): For 240V AC output, up to 10KW max (L+N=240V).
  • Multi-mode Hardwire Terminal (4-wire): Supports L1+L2=240V, L1+N=120V, L2+N=120V, allowing simultaneous 120VAC and 240VAC output.
  • Interruptor de alimentación: To turn the AC output on or off.
  • Ground Wire Connector: Para unha conexión a terra segura.

4.2. Rear Panel (DC Input)

Rear panel of WZRELB 10000W inverter showing DC input terminals and cooling fans

Imaxe: Rear panel of the inverter, featuring positive and negative DC input terminals and cooling fans.

  • Positive (+) Terminal: Terminal vermello para a conexión positiva da batería.
  • Negative (-) Terminal: Terminal negro para a conexión negativa da batería.
  • Ventiladores de refrixeración: Temperature-controlled fans for efficient heat dissipation.
  • Spark-Proof Nut: Designed to minimize sparks during connection.

4.3. Pantalla LCD

LCD display of WZRELB 10000W inverter showing status, battery voltage, temperature, and output details

Imaxe: LCD display showing various operational parameters of the inverter.

The LCD display provides real-time monitoring of the inverter's status:

  1. Inverter working status (Normal/Fault)
  2. Working temperature inside the inverter
  3. Batería voltage e capacidade
  4. AC1 120V voltage e ampera
  5. AC2 120V voltage e ampera
  6. Output of 240V and frequency (60Hz)

5. Instalación

5.1. DC Battery Connection (24V System)

The inverter requires a 24V DC battery system. For a 24V system using two 12V batteries, connect them in series (positive of one battery to negative of the other). Ensure the battery bank is properly sized for your power needs.

Diagram showing DC connection steps for the inverter

Imaxe: Step-by-step guide for connecting DC cables to the inverter, emphasizing spark-proof connection.

  1. Connect Negative Cable First: After connecting the black cable(s) to the battery's negative terminal, connect the other end of the black cable(s) to the inverter's negative terminal.
  2. Contact Spark-Proof Terminal: Briefly touch the spark-proof terminal with the positive cable for 3-5 seconds to discharge any residual capacitance.
  3. Connect Positive Cable: Connect the red cable(s) to the battery's positive terminal, then connect the other end to the inverter's positive terminal.

Importante: Use all provided cables. For 4 cables, use 2 black for negative and 2 red for positive. Ensure all connections are tight to maintain stable current flow.

5.2. AC Output Wiring

The inverter supports both 120V and 240V AC output. You can use the standard 120V outlets or the hardwire terminals for direct connection to your electrical panel.

Close-up of AC output terminals on the inverter

Imaxe: Detallado view of the AC output terminals, including L1, N, L2, and G (Ground) connections.

For hardwire connections:

  • L1 to Hot 1
  • L2 to Hot 2
  • N to Neutral
  • G ao chan

The inverter can run 120V and 240V appliances simultaneously. Ensure the total amperage does not exceed 25A for the connection.

6. Funcionamento

Once the inverter is properly installed and connected to the battery bank, press the power switch on the front panel to turn it on. The LCD display will illuminate, showing the current operational status.

6.1. Conexión de electrodomésticos

Plug your 120V AC appliances into the standard outlets or connect 120V/240V appliances to the hardwire terminals. Ensure the total wattagA potencia nominal dos electrodomésticos conectados non supera a potencia nominal continua do inversor de 10000 W.

Vídeo: Demonstrates various applications of the inverter, powering appliances like electric stoves, baking pans, air fryers, and refrigerators. Note: Video title mentions 6000W, but content is relevant to general inverter applications.

The inverter is compatible with a wide range of appliances, including those for home, cabin, mobile business, RV, trailer, semi-truck, and boat use. It supports AGM, gel, flooded, lead-acid, and lithium-ion batteries.

7. Características de protección

The WZRELB inverter is equipped with multiple protection features to ensure safe and reliable operation:

  • Temperature-Controlled Cooling Fan: Activates automatically to prevent overheating.
  • Baixo Voltage Alarm/Shutdown: Protects batteries from over-discharge.
  • Alto Voltage Alarm/Shutdown: Protects the inverter and connected devices from over-voltage.
  • Protección contra sobrecarga: Shuts down if connected load exceeds capacity.
  • Protección contra curtocircuítos: Evita danos por curtocircuítos.
  • Protección contra sobretemperatura: Apágase se a temperatura interna se fai demasiado alta.
  • Internally Fused: Provides additional circuit protection.
  • Protección contra polaridade inversa da batería: Guards against incorrect battery connections.
WZRELB 10000W Split Phase Inverter with icons representing various protection features

Imaxe: Acabadoview of the inverter highlighting its robust protection features.

8. Especificacións

CaracterísticaEspecificación
MarcaWZRELB
Nome do modeloSPVC10K24V
Wattage (Continuo)10000 vatios
Potencia máxima de saída20000 vatios
Vol. De entradatage24 voltios DC
Vol. De saídatage120 Volts AC, 240 Volts AC
Electrical Output WaveformPura Sine Wave
EficienciaAta o 91.6%
Tipo de visualizaciónLCD
Dimensións do artigo (L x W x H)23 cm de longo x 6.2 cm de ancho x 12 cm de alto
Peso do elemento37 libras
CorNegro
Medios incorporadosInverter, Cables, Fuse
Energy Specifications MetUL

9. Mantemento

  • Limpeza regular: Manteña o inversor limpo e libre de po e residuos. Use un pano seco para limpar.
  • Comproba as conexións: Periodically inspect all DC and AC connections to ensure they are tight and free from corrosion.
  • Ventilación: Ensure cooling fans are not obstructed and operate freely.
  • Saúde da batería: Monitor your battery bank's health and charge levels regularly to prolong their lifespan and ensure optimal inverter performance.

10 Solución de problemas

If you encounter issues with your inverter, refer to the LCD display for error codes or status messages. Common issues and basic troubleshooting steps include:

  • Sen potencia de saída: Check battery connections, ensure the inverter is turned on, and verify battery voltage is within the operating range. Check for tripped circuit breakers or blown fuses.
  • Apagado por sobrecarga: Reduce the load connected to the inverter. Ensure the total wattage of appliances does not exceed the inverter's capacity.
  • Vol. Baixo/Altotage Apagado: Comprobar vol. bateríatage. If low, recharge batteries. If high, check charging system.
  • Apagado por sobretemperatura: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans. Allow the inverter to cool down.
  • Curto circuíto: Disconnect all loads and check for any short circuits in your wiring or appliances.

Para problemas persistentes, póñase en contacto co servizo de atención ao cliente.

11. Garantía

The WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter comes with a 1 ano de garantía from the date of purchase. This warranty covers manufacturing defects and workmanship under normal use. It does not cover damage caused by misuse, improper installation, accidents, or unauthorized modifications.

Conserve o comprobante de compra para reclamacións de garantía.

12. Atención ao cliente

For technical assistance, warranty claims, or any questions regarding your WZRELB inverter, please contact WZRELB customer support through the retailer where you purchased the product or visit the official WZRELB websitio para información de contacto.

© 2023 WZRELB. Todos os dereitos reservados.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.