Chatsworth P5-1C0A5

Chatsworth P5-1C0A5 Switched Vertical eConnect PDU User Manual

Model: P5-1C0A5

1. Introdución

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Chatsworth P5-1C0A5 Switched Vertical eConnect Power Distribution Unit (PDU). Please read this manual thoroughly before using the product and retain it for future reference.

2. Información de seguridade

Observe the following safety precautions to prevent injury and damage to the PDU or connected equipment:

  • Ensure the PDU is installed by qualified personnel in accordance with all local and national electrical codes.
  • Do not open the PDU enclosure. There are no user-serviceable parts inside.
  • Connect the PDU only to a properly grounded power source.
  • Do not overload the PDU. The total current draw of connected devices must not exceed the PDU's rated capacity (20A).
  • Operate the PDU within its specified environmental conditions, including the maximum ambient temperature of 149°F (65°C).
  • Desconecte a alimentación antes de realizar calquera procedemento de mantemento ou instalación.

3. Produto rematadoview

The Chatsworth P5-1C0A5 is a Switched Vertical eConnect PDU designed for efficient power distribution and remote management in data center environments. It features 24 individually switched 5-20R outlets, a graphical local display, and comprehensive network monitoring capabilities.

Chatsworth P5-1C0A5 Switched Vertical eConnect PDU showing outlets, circuit breakers, and control panel.

Imaxe 1: Acabadoview of the Chatsworth P5-1C0A5 PDU. This image displays the vertical PDU with its numerous 5-20R outlets, labeled circuit breakers (CB1, CB2, CB3), and the integrated control panel featuring a graphical display, navigation buttons, Ethernet ports, and a USB port.

Compoñentes clave:

  • L5-20 Input Plug: For connecting the PDU to the main power source.
  • Circuit Breakers (CB1, CB2, CB3): Provide overcurrent protection for groups of outlets. Each breaker has an ON/OFF switch.
  • 5-20R Outlets: Twenty-four (24) individually switched outlets for connecting IT equipment.
  • Graphical Local Display: Provides real-time power monitoring, configuration, and status information directly on the unit.
  • Portos Ethernet: For network connectivity, enabling IP-based remote monitoring and management.
  • Porto USB: Used for firmware updates and configuration backups.
  • Porto de serie: For direct console access and management.

4. Configuración

4.1 Montaxe

The P5-1C0A5 is a vertical PDU designed for tool-less mounting in standard server racks. Ensure the rack has appropriate mounting points and sufficient space for the PDU and its connected cables. Refer to your rack's documentation for specific mounting instructions.

4.2 Conexión de alimentación

  1. Ensure all circuit breakers on the PDU are in the OFF position.
  2. Connect the PDU's L5-20 input plug to a dedicated 1-Phase, 110-125V, 20A power circuit.
  3. Verify the power source is properly grounded.

4.3 Equipos de conexión

  1. With the PDU still powered off (breakers OFF), connect your IT equipment power cords to the 5-20R outlets on the PDU.
  2. Distribute the load evenly across the PDU's outlets and circuit breaker groups to prevent overloading any single breaker.

4.4 Conexión de rede

For remote monitoring and management, connect an Ethernet cable from your network switch to one of the Ethernet ports on the PDU's control panel. Refer to the PDU's network configuration guide for initial setup of IP addresses and network settings.

5. En funcionamento

5.1 Acendido/Apagado

  1. After connecting all equipment, switch the main circuit breakers (CB1, CB2, CB3) on the PDU to the ON position.
  2. The graphical local display will illuminate, indicating the PDU is operational.
  3. Individual outlets can be switched ON or OFF via the local display interface or remotely through the network interface.

5.2 Local Display Operation

Use the navigation buttons adjacent to the graphical display to browse through menus, view real-time power metrics (voltage, current, power, energy), and configure basic settings. Consult the detailed eConnect PDU user guide for comprehensive local display functionality.

5.3 Monitorización e xestión remotas

Access the PDU's web interface via its assigned IP address to perform advanced monitoring, configuration, and control. This includes:

  • Real-time power monitoring of the entire PDU and individual outlets.
  • Individual outlet switching and sequencing.
  • Setting up alerts and notifications for power events.
  • User management and security settings.

The PDU also supports serial monitoring for direct console access.

6. Mantemento

6.1 Limpeza

Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure the PDU is powered off and disconnected from the power source before cleaning.

6.2 Actualizacións de firmware

Chatsworth may release firmware updates to improve performance or add new features. These updates can typically be applied via the USB port or through the network interface. Refer to the Chatsworth support websitio web para obter o firmware e as instrucións de actualización máis recentes.

6.3 Consideracións ambientais

The PDU is designed to operate in high ambient temperatures up to 149°F (65°C). Ensure proper airflow around the unit to prevent overheating. Regularly check the operating environment to ensure it remains within specified limits.

7 Solución de problemas

7.1 No Power to Outlets

  • Verify the main L5-20 input plug is securely connected to a live power source.
  • Check if the PDU's circuit breakers (CB1, CB2, CB3) are in the ON position. If a breaker has tripped, switch it OFF, wait a few seconds, and then switch it back ON. If it trips again, reduce the load on that breaker.
  • Confirm that individual outlets are switched ON via the local display or remote interface.

7.2 Problemas de conectividade de rede

  • Ensure the Ethernet cable is securely connected to both the PDU and the network switch.
  • Verify network settings (IP address, subnet mask, gateway) on the PDU are correct.
  • Check network switch port status and connectivity.

7.3 Breaker Trips Repeatedly

A repeatedly tripping breaker indicates an overload condition. Reduce the total current draw of devices connected to that breaker's group of outlets. If the issue persists with a reduced load, contact technical support.

8. Especificacións

CaracterísticaEspecificación
Número de modeloP5-1C0A5
MarcaChatsworth
Enchufe de entradaL5-20
Vol. De entradatage1-Phase, 110-125V
Corrente de entrada20A
Puntos de venda(24) 5-20R Outlets
Rompedores1 x 2P 20A Hydraulic Magnetic Breakers
Protección contra sobretensionesNon
SeguimentoEthernet, IP, Serial, USB, Graphical Local Display
Temperatura de funcionamentoAta 149 °F (65 °C)
Dimensións aproximadas (paquete)82 x 10 x 8 polgadas
UPC703957370393

9. Garantía e soporte

For warranty information, technical support, or service inquiries, please contact Chatsworth Products customer service or visit their official websitio. Garda á man o recibo da compra e o número de serie do produto cando contactes co servizo de asistencia.

© 2025 Chatsworth Products. All rights reserved.

Documentos relacionados - P5-1C0A5

Preview Guía de referencia rápida das PDU eConnect de CPI
Unha guía de referencia rápida para as unidades de distribución de enerxía (PDU) eConnect de CPI, que detalla as características, especificacións e números de peza de varios modelos, incluíndo Basic, Metered, Monitored, Monitored Pro, Switched e Switched Pro.
Preview PDU CPI Switched Pro eConnect: Ficha técnica e información de pedidos
Ficha técnica completa e guía de pedidos para as PDU CPI Switched Pro eConnect. Este documento detalla as características, as especificacións e os números de peza para as configuracións verticais e horizontais, destacando a monitorización remota da enerxía, o control das tomas de corrente e as capacidades avanzadas de xestión de enerxía do centro de datos.
Preview Tripp Lite PDU3EVSR6L2130: 3-Phase Switched 0U Vertical PDU Technical Specification
Detailed specifications and features for the Tripp Lite PDU3EVSR6L2130, a 3-Phase Switched 0U Vertical Power Distribution Unit designed for rack-mount server, network, and telecom applications.
Preview Legrand PDU Switched Node 0U, 1 Phase 32A - 20 C13 + 2 C19 with Cord Locking
Technical datasheet for the Legrand PDU Switched Node 0U, a 1-phase 32A intelligent power distribution unit featuring 20 C13 and 2 C19 outlets with cord locking, IEC 60309 connector, and advanced monitoring capabilities for data center applications.
Preview Legrand PDU Switched Node 0U, 3 Phase 16A - Technical Datasheet
Detailed technical datasheet for the Legrand PDU Switched Node 0U, 3 Phase 16A, featuring 24 C13 and 6 C19 outlets with cord locking, IEC 60309 connector, and advanced remote monitoring capabilities.
Preview Chatsworth Products EA-61D7W-X eConnect Vertical PDU Technical Specifications
Detailed technical specifications for the Chatsworth Products EA-61D7W-X eConnect Vertical PDU, featuring 208V three-phase input, 60A IEC 60309 connector, 18 C13/C15 outlets, and 18 QuadLock outlets.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.