OUMIFAND SU600

OUMIFAND SU600 Series Variable Frequency Drive (VFD) Instruction Manual

Model: SU600-0R75G1 (0.75KW variant)

1. Introdución

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the OUMIFAND SU600 Series Variable Frequency Drive (VFD). The SU600 VFD is designed to convert single-phase 220V input power to three-phase 380V output, enabling precise speed control for three-phase motors ranging from 0.75KW to 5.5KW. Please read this manual thoroughly before using the product.

2. Información de seguridade

Observe sempre as seguintes precaucións de seguridade para evitar lesións persoais ou danos ao equipo:

  • Risco eléctrico: Ensure all power is disconnected before installation, wiring, or maintenance. Only qualified personnel should perform electrical work.
  • Conexión a terra: The VFD must be properly grounded to prevent electric shock.
  • Protección contra sobrecarga: Do not exceed the rated current or power of the VFD and connected motor.
  • Ambiente: Install the VFD in a clean, dry, and well-ventilated area, away from direct sunlight, corrosive gases, and excessive vibration.
  • Descarga do condensador: Wait at least 5 minutes after disconnecting power before touching internal components, as capacitors may retain a dangerous charge.

3. Produto rematadoview

The OUMIFAND SU600 VFD is a robust frequency converter designed for industrial applications. It features a compact design and a user-friendly interface for controlling motor speed and torque.

OUMIFAND SU600 VFD with key product parameters displayed

Figure 3.1: SU600 VFD Product Parameters. This image displays the OUMIFAND SU600 Variable Frequency Drive, highlighting its model number SU600-0R75G1, adapted motor power of 0.75KW (1HP), input voltage of single-phase 220V, output voltage of three-phase 380V, current of 2.5A, dimensions of 147x72x118.4mm, and a weight of 0.72Kg.

Internal components of the OUMIFAND SU600 VFD, showing main board characteristics

Figure 3.2: Inverter Components Display. This image shows the internal components of the SU600 VFD, emphasizing the main board's characteristics: waterproof, moisture-proof, and mildew-proof design for enhanced durability in various environments.

4. Configuración e instalación

Proper installation is crucial for the VFD's performance and safety. Follow the wiring diagram carefully.

4.1 Diagrama de cableado

Connect the input power, motor, and optional brake resistor according to the diagram below. Ensure all connections are secure and correctly polarized.

Wiring diagram for OUMIFAND SU600 VFD showing input, output, and ground connections

Figure 4.1: SU600 VFD Wiring Diagram. This diagram illustrates the connection points for the OUMIFAND SU600 VFD. It shows the input power connection (R, S/L1, T/L2), output power connection to the motor (U, V, W), brake resistor connection (P+, PB), and the essential ground wire connection.

  • Potencia de entrada: Connect single-phase 220V AC power to terminals R and S/L1.
  • Saída do motor: Conecte o motor trifásico aos terminais U, V e W.
  • Conexión a terra: Connect the ground wire to the designated ground terminal.
  • Brake Resistor (Optional): For applications requiring rapid deceleration, connect an external brake resistor to terminals P+ and PB.

5. Instrucións de funcionamento

The SU600 VFD features a control panel for easy operation and parameter setting.

5.1 Panel de control rematadoview

Familiarize yourself with the buttons and indicators on the VFD's control panel.

OUMIFAND SU600 VFD control panel with button functions and display interface explained

Figure 5.1: Operation and Display Interface. This image details the control panel of the SU600 VFD. It labels the Forward (FWD), Reverse (REV), Frequency (Hz), Current (A), Voltage (V), and Alarm (ALM) indicators. Key buttons include Programming (PRG), Confirm (ENT), Run, Stop, Incremental, and Decrement keys. An external network port and an optional external operation panel are also shown.

5.2 Funcionamento básico

  1. Encendido: After ensuring all wiring is correct, apply power to the VFD. The display will light up.
  2. Arranque do motor: Preme o CORRER botón para arrincar o motor.
  3. Adjust Frequency/Speed: Usa o Incremental e Decrecemento keys to adjust the output frequency, thereby controlling the motor speed.
  4. Parada do motor: Preme o PARA botón para parar o motor.
  5. Configuración de parámetros: Preme o PRG (Programming) key to enter the parameter setting mode. Use the Incremental/Decrement keys to navigate and the ENT (Confirm) key to select and save parameters.

6. Mantemento

Un mantemento regular garante a lonxevidade e o funcionamento fiable do seu variador de frecuencia.

  • Limpeza: Keep the VFD clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Ventilación: Ensure proper airflow around the VFD. Regularly check and clean cooling fans and vents.
  • Conexións: Comprobe periodicamente todas as conexións eléctricas para comprobar se están ben apertadas e se presentan signos de corrosión.
  • Verificación ambiental: Supervisar o ambiente de funcionamento para garantir que se manteña dentro dos rangos de temperatura e humidade especificados.

7 Solución de problemas

This section provides basic troubleshooting steps for common issues. For complex problems, contact technical support.

ProblemaCausa posibleSolución
O variador de frecuencia non se acendeNo input power; Incorrect wiringCheck power supply; Verify wiring connections
O motor non arrancaIncorrect parameters; Motor overload; Emergency stop activeCheck parameter settings; Reduce load; Reset emergency stop
Fallo de sobreintensidadeMotor short circuit; Sudden load change; Acceleration time too shortCheck motor and wiring; Adjust acceleration time; Reduce load
Sobrevoltage culpaVol. De entradatage too high; Deceleration time too short; No brake resistorComprobar o vol. de entradatage; Increase deceleration time; Install brake resistor

8. Especificacións

Detailed technical specifications for the OUMIFAND SU600 Series VFD.

ParámetroValor
MarcaOUMIFAND
Serie modeloSU600
Vol. De entradatageMonofásico de 220 V
Vol. De saídatage380V trifásico
Faixa de frecuencia de saída50-400 Hz
Rango de potencia de saída0.75KW - 5.5KW
Rango de corrente de saída2.5A - 13A (varies by model power)
TipoInversor CC/CA
Dimensions (0.75KW model)147 mm (L) x 72 mm (An) x 118.4 mm (Al)
Weight (0.75KW model)0.72 kg
General Dimensions Range147x72x119mm to 185x87x138mm
General Weight Range1-2 kg
País de OrixeChina

9. Garantía e soporte

For warranty information and technical support, please refer to the documentation provided with your purchase or contact OUMIFAND customer service. Keep your purchase receipt as proof of purchase.

Ask a question about this manual