1. Introdución
This manual provides detailed instructions for the safe and efficient operation, maintenance, and troubleshooting of your iwoly D300 Cordless Vacuum Cleaner. Please read this manual thoroughly before first use and retain it for future reference.
The iwoly D300 is a versatile 2-in-1 stick and handheld vacuum cleaner designed for various cleaning tasks. It features a powerful brushless motor, multiple suction modes, and an efficient filtration system.

Image: The iwoly D300 Cordless Vacuum Cleaner shown in its full stick configuration and as a compact handheld unit with different attachments.
2. Que está incluído
Desembala coidadosamente todos os compoñentes e compróbaos coa lista seguinte. Se falta algún elemento ou está danado, ponte en contacto co servizo de atención ao cliente.
- Cordless Vacuum Main Body
- LED Motorized Floor Brush Head
- Tubo de extensión
- Lithium-ion Battery (Detachable)
- AC Adapter (26V Charger)
- Cepillo para polvo 2 en 1
- Boquilla de fendas longas
- Wall-mounted Bracket & Screws
- Filtro de aceiro inoxidable
- Filtro HEPA
- Manual de usuario (este documento)

Image: A visual representation of all parts included with the iwoly D300 Cordless Vacuum Cleaner, such as the main unit, various brushes, filters, and charging accessories.
3. Configuración e montaxe
3.1 Carga inicial
- Ensure the battery is securely inserted into the main vacuum body or charged separately.
- Connect the AC adapter to the charging port on the vacuum or directly to the battery.
- Plug the AC adapter into a power outlet. The battery indicator lights will illuminate during charging.
- A full charge takes approximately 4 hours. The indicator lights will show a full charge when complete.
3.2 Montaxe da aspiradora de man
- Insert the extension tube into the main vacuum body until it clicks into place.
- Attach the LED motorized floor brush head to the other end of the extension tube until it clicks.
- Asegúrese de que todas as conexións sexan seguras antes do uso.
3.3 Montaxe da aspiradora de man
- Remove the extension tube and floor brush head from the main vacuum body.
- Attach the desired accessory (e.g., 2-in-1 dusting brush or crevice nozzle) directly to the main vacuum body until it clicks.

Image: The iwoly D300 vacuum cleaner stored on its wall mount, demonstrating direct charging and separate battery charging options.
4. Instrucións de funcionamento
4.1 Modos de acendido/apagado e succión
- Press the power button to turn the vacuum cleaner on. It will start in the default suction mode.
- Press the mode button to cycle through the three available suction modes: Low, Mid, and Max.
- Prema o botón de acendido de novo para apagar o aspirador.
The iwoly D300 offers up to 28,000Pa of suction power in Max mode, suitable for various debris types including pet hair and fine dust.

Image: A visual representation of the vacuum's suction capabilities, showing different suction levels for dust, pet hair, and pet food.
4.2 Usando anexos
- LED Motorized Floor Brush Head: Ideal for hard floors and low-pile carpets. The integrated LED lights illuminate dust and debris in dark areas. Note: Not suitable for high-pile rugs.
- Cepillo para quitar o po 2 en 1: Use the brush bristles for delicate surfaces like keyboards, curtains, and upholstery. Retract the bristles for a wider nozzle to clean larger areas.
- Boquilla longa para fendas: Designed for reaching tight spaces, corners, and crevices in furniture, car interiors, and along baseboards.

Image: The iwoly D300 in action, highlighting its LED headlights for dark areas and its use with different attachments for cleaning sofas, stairs, and general floor surfaces.
5. Mantemento
Un mantemento regular garante un rendemento óptimo e prolonga a vida útil do teu aspirador.
5.1 Baleirar o colector de lixo
- Asegúrate de que o aspirador estea apagado.
- Coloca o colector de lixo sobre un colector de lixo.
- Prema o botón de apertura do colector de po para abrir a solapa inferior e baleirar o contido.
- Peche a tapa do colector de po con seguridade.
The 1.2L large-capacity dustbin allows for extended cleaning sessions before needing to be emptied.

Image: A user demonstrating how to empty the 1.2L dust cup with a single touch and how to wash the components under running water.
5.2 Limpeza dos filtros
The iwoly D300 features a 6-stage sealed cyclone filtration system, including a HEPA filter, plastic filter, and stainless steel filter. These components are washable and reusable.
- Asegúrate de que o aspirador estea apagado e que o colector de po estea baleiro.
- Twist and remove the dustbin from the main body.
- Carefully remove the internal filter components (HEPA filter, plastic filter, stainless steel filter).
- Rinse all washable filter components under cool running water until clean. Do not use detergents.
- Deixa que todos os compoñentes do filtro sequen completamente ao aire durante polo menos 24 horas antes de volvelo montar. Non uses o aspirador con filtros húmidos.
- Reassemble the filters and dustbin in reverse order.

Imaxe: Unha explosión view diagram detailing the 6-stage filtration system, including the 1.2L dust cup, plastic filter, stainless steel filter, multi-cyclone filtration, upgraded HEPA filter, and air outlet sponge filter.
5.3 Limpeza da cabeza do cepillo
- Ensure the vacuum is turned off and disconnected from power.
- Detach the motorized floor brush head from the extension tube.
- Locate the brush roll release mechanism (usually a latch or button) and remove the brush roll.
- Use scissors or a cleaning tool to remove any tangled hair or debris from the brush roll.
- Clean the inside of the brush head housing.
- Volva colocar o rolo de cepillo e asegúreo no seu lugar.
6 Solución de problemas
Se tes algún problema, consulta a seguinte táboa para ver os problemas e as solucións máis habituais.
| Problema | Causa posible | Solución |
|---|---|---|
| O baleiro non se acende | A batería non está cargada ou non está instalada correctamente. | Cargue a batería completamente. Asegúrese de que a batería estea ben encaixada no seu lugar. |
| Perda de potencia de succión | Dustbin is full. Filters are clogged. Blockage in the nozzle, tube, or brush head. | Baleirar o colector de po. Limpar ou substituír os filtros. Comprobar e eliminar calquera obstrución. |
| O rolo de pincel non xira | Hair or debris tangled in the brush roll. Brush roll is not properly installed. | Clean the brush roll of any obstructions. Reinstall the brush roll correctly. |
| A duración da batería é curta | Operating in Max suction mode. Battery not fully charged. Battery degradation. | Use lower suction modes for longer runtime. Ensure battery is fully charged (4 hours). Contact support if battery life significantly decreases over time. |
| Charging indicator lights not working | Charger not connected properly. Power outlet issue. | Ensure the charger is securely connected to both the vacuum/battery and the power outlet. Try a different power outlet. |
7. Especificacións
| Característica | Especificación |
|---|---|
| Nome do modelo | iwoly D300 Cordless Vacuum Cleaner |
| Marca | iwoly |
| Motor | Brushless Motor, 200 Watts |
| Aspiración máxima | 28,000 Pa (280 Centimeters) |
| Modos de succión | 3 (Low, Mid, Max) |
| Tipo de batería | Detachable Lithium-Ion (2200mAh) |
| Duración da batería | Up to 38 minutes (Low mode), 20 minutes (Mid mode), 14 minutes (Max mode) |
| Tempo de carga | 4 horas |
| Capacidade do lixo | 1.2 litros |
| Tipo de filtro | 6-stage sealed cyclone filtration system with HEPA Filter (Washable) |
| Nivel de ruído | 75 decibeis |
| Dimensións do produto | 10.63 cm de longo x 47.24 cm de ancho x 5.51 cm de alto |
| Peso do elemento | 5.5 libras |
| Características especiais | Cordless, HEPA, Headlight, Rechargeable, Washable Filter |
| Usos recomendados | Indoor (bedroom, kitchen, living room, car) |
8. Garantía e soporte
For warranty information, product support, or to purchase replacement parts, please refer to the contact information provided with your product packaging or visit the official iwoly websitio.
Conserve o comprobante de compra para reclamacións de garantía.