Dasan AT249W-ORB
DASAN AT249W-ORB Wall Mount Shower System Instruction Manual
Model: AT249W-ORB | Brand: Dasan
1. Introdución
This manual provides detailed instructions for the installation, operation, and maintenance of your DASAN AT249W-ORB Wall Mount Shower System. Please read this manual thoroughly before installation and retain it for future reference. Proper installation and care will ensure optimal performance and longevity of your shower system.
2. Información de seguridade
- Peche sempre a subministración principal de auga antes de comezar calquera traballo de fontanería.
- Use equipos de protección persoal axeitados, como lentes e luvas de seguridade.
- Se tes algunha dúbida sobre calquera parte do proceso de instalación, consulta cun fontaneiro cualificado.
- Asegúrate de que todas as conexións estean seguras para evitar fugas.
- Do not overtighten components, as this may cause damage.
3. Contido do paquete
Verify that all components are present and undamaged before installation. If any parts are missing or damaged, please contact customer support.

Imaxe: Explosión view of the DASAN AT249W-ORB shower system components.
- Cabezal de ducha
- Placa frontal
- Válvula de desbaste
- Brazo de ducha
- Handheld Wand
- Codo de alimentación de parede
- Body Jets (4 units)
- Shower Handle
- Hardware de montaxe
- Diverter Knob
- Flange for Handheld
- Shower Hose (59 inches)
- Flange for Shower Arm
4. Especificacións
| Característica | Especificación |
|---|---|
| Marca | Dasan |
| Número de modelo | AT249W-ORB |
| Cor | Bronce Aceiteado |
| Material | Latón, aceiro inoxidable |
| Tipo de acabado | Mate |
| Número de tiradores | 1 |
| Tipo de montaxe | Montado na parede |
| Caudal | 1.8 GPM |
| Tamaño da cabeza de ducha | 9 polgadas |
| Lonxitude da mangueira de ducha | 59 polgadas |
| In-Wall Depth (Min-Max) | 2-3/16" (55 mm) to 3-1/16" (78 mm) |
| Conexións | 1/2" Male NPT |

Image: Pressure balance rough-in valve details, including in-wall depth and connections.
5. Instrucións de instalación
It is recommended to have this product installed by a professional plumber. Ensure the main water supply is turned off before proceeding.
5.1 Pasos previos á instalación
- Confirma que todo o contido do paquete estea presente e sen danos.
- Prepare the wall opening according to the rough-in valve dimensions, ensuring the in-wall depth is between 2-3/16" (55 mm) and 3-1/16" (78 mm).
- Flush the water lines to remove any debris before connecting the valve.
5.2 Rough-in Valve Installation
- Mount the rough-in valve (3) securely within the wall, ensuring it is level and at the correct depth.
- Connect the hot and cold water supply lines to the designated inlets on the valve (1/2" NPT connections).
- Connect the mixed outlets from the valve to the rain shower, handheld shower, and body jet supply lines.
- Perform a leak test by turning on the main water supply and checking all connections.
5.3 Instalación de compoñentes
- Shower Arm and Head: Install the shower arm (4) into the wall outlet, ensuring it is securely tightened. Attach the shower head (1) to the shower arm.
- Handheld Shower: Install the wall supply elbow (6) for the handheld shower. Connect the shower hose (12) to the wall supply elbow and the handheld wand (5). Mount the flange (11) for the handheld.
- Chorros de corpo: Install the body jets (7) into their respective wall outlets. Ensure they are securely tightened and oriented as desired.
- Face Plate and Handle: Install the face plate (2) over the rough-in valve. Attach the shower handle (8) and diverter knob (10) according to the valve's instructions, securing them with the provided mounting hardware (9).

Imaxe: Máis deview of the assembled DASAN AT249W-ORB shower system.
6. Instrucións de funcionamento
Your DASAN shower system offers multiple functions for a customized showering experience.

Image: Control functions for the shower system.
6.1 Control de temperatura e fluxo
- The main handle controls both water temperature and flow.
- Rotate the handle to adjust the temperature from cold to hot.
- Pull the handle outwards to increase water flow and push inwards to decrease it.
6.2 Function Selection (Diverter Knob)
The diverter knob allows you to switch between the rain shower, handheld shower, and body jets.
- Chuvia: Rotate the diverter knob to activate the overhead rain shower. The 9-inch shower head provides broad coverage.
- Handheld Shower: Rotate the diverter knob to activate the handheld shower. The 59-inch hose allows for flexible use.
- Chorros de corpo: Rotate the diverter knob to activate the body spray jets. These jets feature a 360-degree adjustable angle for targeted water flow.

Image: Rain shower head with adjustable angle feature.

Image: Handheld shower head with 59-inch hose and brass supply holder.

Image: Body jets with easy-clean nozzles and 360-degree adjustable angle.
7. Mantemento
Regular cleaning and maintenance will help preserve the finish and functionality of your shower system.
- Limpeza do acabado: Clean the oil rubbed bronze finish with a soft, damp pano. Evite produtos de limpeza abrasivos, produtos químicos agresivos ou estropaxos, xa que poden danar o acabado.
- Boquillas de limpeza: The rain shower head, handheld shower, and body jets feature silicone nozzles. To remove mineral buildup (limescale), gently rub the nozzles with your finger or a soft brush. This helps maintain consistent water flow.
- Comprobacións periódicas: Periodically check all connections for tightness and signs of leaks.
8 Solución de problemas
Se tes problemas co sistema de ducha, consulta os seguintes problemas e solucións comúns:
| Problema | Causa posible | Solución |
|---|---|---|
| Baixo caudal de auga | Clogged nozzles, partially closed shut-off valves, debris in lines. | Clean silicone nozzles. Ensure shut-off valves are fully open. Flush water lines if debris is suspected. |
| Fugas de auga | Loose connections, damaged O-rings/washers. | Tighten all connections. Inspect and replace any damaged O-rings or washers. Do not overtighten. |
| Temperatura da auga inconsistente | Pressure balance valve issue, hot/cold water supply imbalance. | Ensure hot and cold water supplies are balanced. If the problem persists, consult a plumber to inspect the pressure balance valve. |
| Diverter Not Switching Functions | Debris in diverter mechanism, worn diverter cartridge. | Flush the system. If the issue continues, the diverter cartridge may need inspection or replacement by a professional. |
If these solutions do not resolve the issue, please contact Dasan customer support.
9. Información da garantía
The DASAN AT249W-ORB Wall Mount Shower System comes with the following warranty:
- Uso residencial: Garantía limitada de 10 anos
- Uso comercial: Garantía limitada de 5 anos
Please retain your proof of purchase for warranty claims. The warranty covers manufacturing defects under normal use and service. For full warranty terms and conditions, please refer to the official Dasan websitio ou póñase en contacto co servizo de atención ao cliente.
10. Apoio
For further assistance, technical support, or to inquire about replacement parts, please visit the official Dasan store or contact their customer service department.
Visit the Dasan Store: Dasan Official Store
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.