1. Información importante de seguridade

Read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards.

  • Always disconnect power at the circuit breaker before servicing or cleaning the unit.
  • A instalación debe ser realizada por un electricista cualificado de acordo con todos os códigos eléctricos locais e nacionais.
  • Do not use this fan with any solid-state speed control device unless specifically approved for use with this model.
  • Asegúrese de conectar a terra adecuada para reducir o risco de descarga eléctrica.
  • Esta unidade está deseñada só para uso xeral de ventilación. Non a empregue para extraer materiais e vapores perigosos ou explosivos.

2. Contido do paquete

Carefully unpack the fan and check for any shipping damage. Ensure all parts are present before discarding packaging materials. If any parts are missing or damaged, contact Akicon customer support.

Vídeo: Akicon Bathroom Exhaust Fan Unboxing & Installation. This video demonstrates the unboxing process and shows the included components, as well as various installation methods.

  • Exhaust Fan Housing
  • Grille with LED Light and Humidity Sensor
  • Control remoto
  • Modelo de recorte de drywall
  • Hanger Bar/Suspension Brackets (for attic installation)
  • Parafusos de montaxe
  • Manual de instrucións

3. Especificacións

MarcaAkicon
Nome do modeloAkicon HumiditySensorRGB
Capacidade de caudal de aire110 pés cúbicos por minuto (CFM)
Nivel de ruído1.5 Sons
Cobertura do cuartoAta 100 pés cadrados.
Tipo de luzLED (Dimmable, RGB, 3 Color Temperatures: 2700K/4000K/5000K, Nightlight)
Características especiaisHumidity Sensor, RGB Light, Dimmable LED, Nightlight, Quiet Operation
Tipo de montaxeMontaxe no teito
Fonte de enerxíaAC
Dimensións da vivenda9" x 9" x 7.7"
Light Cover Dimension12" x 12"
Apertura do teito9-1/4" (L) x 9-1/4" (W)
Diámetro do conductoΦ4"
CertificaciónsHVI, UL Listed

4. Instalación

4.1 Comprobacións previas á instalación

Before beginning installation, ensure the following:

  • Verify that your soffit or attic has sufficient space for the fan housing. The required opening size is 9-1/4" x 9-1/4" and a minimum soffit/attic height of 7-3/4".
  • Desconecte a alimentación da zona de instalación no interruptor automático.
Diagram showing required attic/soffit space and opening dimensions for installation.

Imaxe: Pre-installation diagram illustrating the necessary ceiling opening dimensions (9-1/4" x 9-1/4") and minimum attic/soffit height (7-3/4") for proper fan installation.

4.2 Ceiling Opening

  1. Use the provided drywall cutout template to mark the ceiling opening.
  2. Carefully cut the 9-1/4" x 9-1/4" opening in the ceiling.

4.3 Cableado

Connect the electrical wires according to the label on the wires. Ensure black wire connects to black, white to white, and ground to ground. A neutral wire is required for operation.

Wiring diagram for the Akicon Bathroom Exhaust Fan.

Imaxe: Detailed wiring diagram showing connections for the fan, including ground, neutral, and live wires to a junction box. This diagram is crucial for correct electrical installation.

4.4 Opcións de instalación

This fan supports multiple installation methods:

Option A: Bracket Attic Installation

This method is used when attic access is available and joists are present for mounting.

  1. Insert suspension brackets (CC) into the tabs on the fan housing and then slide suspension brackets (DD) into suspension brackets (CC).
  2. Screw the housing into the joists using appropriate screws.
  3. Tighten the screws until the fan housing is firmly secured to the brackets.

Option B: Bracket-Free Attic Installation

This method is used when attic access is available and the fan can be directly mounted to joists without additional brackets.

  1. Screw the fan housing directly into the joist using appropriate screws.
  2. Ensure the housing is securely fastened to prevent vibration.

Option C: No Attic Installation

This method is suitable when attic access is not available, allowing installation from below the ceiling.

  1. Remove the screws securing the motor to the housing, and unplug the wires connecting the motor to the housing.
  2. Remove the fan motor assembly from the housing.
  3. After connecting the ventilation duct, send the housing into the ceiling opening.
  4. Connect the wires correctly according to the label on the wires (black to black, white to white, ground to ground).
  5. Secure the housing to the joist from below.
  6. Reinstall the motor back into the housing and connect the plugs.
  7. Instale a reixa.

4.5 Instalación de reixa

Once the fan housing is secured and wired, install the grille:

  1. Connect the light and sensor wires from the grille to the corresponding connectors in the fan housing.
  2. Align the grille mounting springs with the slots in the fan housing.
  3. Push the grille firmly into place until it is flush with the ceiling.

5. Funcionamento

The Akicon Bathroom Exhaust Fan is operated using the included remote control. Ensure the remote has working batteries.

Remote control for Akicon Bathroom Exhaust Fan with button functions labeled.

Imaxe: Remote control layout with labeled buttons for power, brightness, light on/off, fan on/off, humidity sensor, fan timers (15/30 min), night light, RGB on/off, RGB mode switch, and color temperature selection (Warm, Day, Cold Light).

5.1 Funcións básicas

  • Encendido/apagado: Press the 'ON' or 'OFF' button to turn the fan and light on or off.
  • Ventilador aceso/apagado: Press the fan icon button to control the fan independently.
  • Luz ON/OFF: Press the light bulb icon button to control the light independently.

5.2 Sensor de humidade

The fan features an integrated humidity sensor for automatic operation.

  • Activación: Press the 'Humidity Sensor' button on the remote. The blue indicator light on the fan will flash during humidity detection mode.
  • Operación automática: When indoor humidity exceeds 60% RH, the blue light illuminates steadily, and the fan activates automatically to reduce moisture.
  • Desactivación: The fan will continue to operate until the humidity drops below 60% RH, then it will turn off.
Diagram illustrating the humidity sensor operation, showing fan activation above 60% RH and deactivation below 60% RH.

Imaxe: Visual explanation of the humidity sensor's function. It shows the fan activating when humidity is above 60% RH and remaining off when below 60% RH, with air circulation arrows.

5.3 Funcións de iluminación

The fan includes versatile lighting options:

  • LED regulable: Adjust brightness using the '+' and '-' buttons.
  • 3 Temperaturas de cor: Select between 2700K (Warm Light), 4000K (Day Light), and 5000K (Cold Light) using the dedicated buttons.
  • Iluminación dinámica RGB: Press 'RGB ON/OFF' to activate. Use 'RGB Mode Switch' to cycle through Static, Cycle, and Flow modes.
  • Luz nocturna: Press the 'Night Light ON/OFF' button to activate a soft 3000K nightlight.
Illustration of the three RGB dynamic light modes: Static, Cycle, and Flow.

Imaxe: Depiction of the three RGB dynamic light modes: Static (four solid single colors), Cycle (smooth transitions through colors), and Flow (flowing chase light effect). This image helps visualize the different lighting options.

Examples of 3 CCT Dimmable LED light with Night Light settings.

Imaxe: Visual representation of the 3 CCT (Correlated Color Temperature) dimmable LED light settings (3000K, 4000K, 5000K) and the night light feature, demonstrating the adjustable brightness and color options.

5.4 Función de temporizador

Set the fan to operate for a specific duration:

  • Temporizador de 15 minutos: Press the '15 min' button.
  • Temporizador de 30 minutos: Press the '30 min' button.
Image showing the fan activating and then delaying shut-off with a timer.

Imaxe: Illustration of the fan's timer function, showing the fan turning on and then automatically shutting off after a set period (15 or 30 minutes), useful for clearing steam after a shower.

6. Mantemento

Un mantemento regular garante un rendemento óptimo e unha maior duración do seu extractor de aire.

6.1 Cleaning the Grille and Light Cover

  1. Desconectar a enerxía: Desconecte sempre a alimentación no disyuntor antes de limpar.
  2. Eliminar reixa: Gently pull down the grille to disengage the mounting springs.
  3. Limpar: Wipe the grille and light cover with a soft, damp cloth. A mild, non-abrasive detergent can be used if necessary. Do not use harsh chemicals or abrasive cleaners.
  4. Seco: Ensure all parts are completely dry before reattaching.
  5. Reinstalar a grella: Push the grille back into place until the springs engage securely.

6.2 Cleaning the Fan Motor and Housing

Periodically, the fan motor and housing may require cleaning to remove dust and debris.

  1. Desconectar a enerxía: Desconecte a enerxía no interruptor.
  2. Eliminar reixa: Remove the grille as described above.
  3. Motor de acceso: Depending on your installation type, you may need to carefully remove the motor assembly from the housing. Refer to the installation section for guidance on motor removal.
  4. Limpar: Use a vacuum cleaner with a brush attachment or a soft brush to remove dust from the fan blades, motor, and interior of the housing. Do not use water or liquids directly on electrical components.
  5. Remontar: Reinstall the motor assembly and grille, ensuring all connections are secure.
  6. Restaurar enerxía: Volve a conectar o interruptor automático.

7 Solución de problemas

If you experience issues with your Akicon Bathroom Exhaust Fan, refer to the following troubleshooting guide:

ProblemaCausa posibleSolución
O ventilador non se acende
  • Sen fonte de alimentación
  • Conexión de cableado solta
  • Faulty remote control batteries
  • Comprobe o disxuntor e o interruptor de parede.
  • Verifique que todas as conexións dos cables estean seguras (asegúrese primeiro de que a alimentación estea desconectada).
  • Substitúe as pilas do control remoto.
A luz non se acende
  • No power supply to light
  • Loose light connection
  • Comprobe a fonte de alimentación.
  • Ensure light connections are secure (power off).
Fan is noisy or vibrates
  • Parafusos de montaxe soltos
  • Residuos nas aspas do ventilador
  • Problema motor
  • Aperte todos os parafusos de montaxe.
  • Clean fan blades and housing (power off).
  • Se o ruído persiste, póñase en contacto co servizo de atención ao cliente.
Humidity sensor not working
  • Sensor desactivado
  • Sensor obstruído
  • Ensure humidity sensor mode is activated via remote.
  • Clean any dust or debris from the sensor area on the grille.

If the problem persists after trying these solutions, please contact Akicon customer support.

8. Garantía e soporte

Akicon products are manufactured to high-quality standards and are warranted to be free from defects in materials and workmanship. For specific warranty details, duration, and terms, please refer to the warranty card included in your package or visit the official Akicon websitio.

For technical assistance, troubleshooting not covered in this manual, or to report missing/damaged parts, please contact Akicon customer support: