VEVOR AT1-2200X

VEVOR 2.2 kW Variable Frequency Drive (VFD) Instruction Manual

Model: AT1-2200X

1. Introdución

This instruction manual provides essential information for the safe and efficient operation of your VEVOR 2.2 kW Variable Frequency Drive (VFD). This VFD is designed to convert single-phase AC 220-240V input into three-phase AC 220-240V output, enabling precise speed control for various industrial motors. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.

VEVOR 2.2 kW Variable Frequency Drive (VFD) product view

Image: A general view of the VEVOR 2.2 kW Variable Frequency Drive (VFD), showcasinpolo seu deseño compacto e o seu panel de control.

2. Instrucións de seguridade

AVISO: Improper installation or operation can lead to serious injury or property damage. Always follow these safety guidelines.

  • Ensure power is disconnected before any wiring or maintenance.
  • The VFD must be properly grounded to prevent electrical shock.
  • Do not connect U/V/W output directly to AC power supply; this will damage the inverter.
  • Install the inverter in a non-flammable, dry environment, free from explosive gases.
  • Only qualified professionals should perform wiring and installation.
  • Do not open the VFD casing; internal components are under high pressure and can cause injury.
  • The VFD features a 10-layer protection system, including overcurrent, overload, overvoltage, phase loss, and short circuit protection. However, these are supplementary and do not replace safe operating practices.
VEVOR VFD with comprehensive safety protections

Image: Diagram illustrating the VEVOR VFD's comprehensive safety protections, including overcurrent, overload, overvoltage, short circuit, and phase loss protection.

3. Produto rematadoview

The VEVOR 2.2 kW VFD is a robust and efficient solution for controlling the speed of three-phase motors. It offers stable performance, energy efficiency, and a user-friendly interface.

Características principais:

  • Potencia de saída: 2.2 kW (3 HP), 10 A.
  • Entrada: Single-phase AC 220-240 V, 50/60 Hz.
  • Saída: Three-phase AC 220-240 V, 0-400 Hz.
  • Control: Soft start and stop for smooth motor operation.
  • Protección: 10-layer system including overcurrent, overload, overvoltage, phase loss, and short circuit protection.
  • Refrixeración: Powerful fan and multi-hole design for efficient heat dissipation and quiet operation.
  • Interface de usuario: Intuitive control panel with a 5-digit LED display, speed adjustment knob, and removable panel for remote operation (20 cm cable).
  • Durabilidade: High-quality circuit control board and high-temperature resistant plastic casing.
VEVOR VFD with features like remote operation, large cooling fan, high-quality circuit board, and high-temperature resistant casing

Imaxe: Detallada view of the VEVOR VFD highlighting its high-performance features, including support for remote operation, a large cooling fan for rapid heat dissipation, a high-quality circuit control board, and a high-temperature resistant plastic casing.

4. Configuración e instalación

4.1 Diagrama de cableado

Refer to the following diagram for correct wiring. Ensure all connections are secure and comply with local electrical codes.

Wiring diagram for VEVOR 2.2 kW VFD

Image: Wiring diagram showing single-phase AC 220-240V input connected to terminals L and N, and three-phase AC 220-240V output connected to motor terminals U, V, W. Grounding terminal (GND) is also indicated.

4.2 Conexións de terminais

Etiqueta do terminalDescrición da función
L, NTerminal de entrada monofásico AC 220V
U, V, WTerminal de saída conectado a motor trifásico
GNDTerminal de terra

Importante: Ensure the motor's wiring configuration is set for 220V three-phase operation if it is a dual-voltage motor (e.g., 220V/380V).

5. Instrucións de funcionamento

5.1 Panel de control rematadoview

The VFD features an intuitive control panel for easy operation and parameter adjustment.

VEVOR VFD control panel layout

Imaxe: Detallada view of the VEVOR VFD control panel, showing the 5-digit LED display, status indicators, speed adjustment knob, and function keys (DISP, FWD/REV, PROG, FUNC/DATA, RUN, STOP/RESET).

  • Indicador de estado: Displays current operating status (Power, Run, Stop, FWD, REV, r/min).
  • Pantalla LED de 5 díxitos: Shows frequency, speed, and parameter values.
  • Botón de axuste de velocidade: Úsase para axustar a frecuencia de saída/velocidade do motor.
  • Botón EXECUTAR: Inicia a saída do inversor.
  • Botón de PARADA/RESET: Stops the inverter output or resets fault conditions.
  • FWD/REV Key: Toggles between forward and reverse rotation.
  • Botón DISP: Shifts between programming modes or jog mode in normal operation.
  • Botón PROG: Used for selecting programming mode or programming.
  • FUNC/DATA Button: Used for setting function data.
  • Frechas cara arriba/abaixo: Para navegar polos menús e axustar valores.

5.2 Funcionamento básico

  1. Encendido: Connect the VFD to the power supply. The LED display will light up.
  2. Establecer frecuencia: Xire o Botón de axuste de velocidade to set the desired output frequency (0-400 Hz).
  3. Arranque do motor: Preme o CORRER button to start the motor. The motor will accelerate to the set frequency.
  4. Cambiar dirección: Preme o FWD/REV key to switch between forward and reverse rotation.
  5. Parada do motor: Preme o PARAR / RESETAR botón para parar o motor.
  6. Reset Fault: If a fault occurs, the VFD will display an error code. Press PARAR / RESETAR to clear the fault after addressing the issue.

5.3 Configuración de parámetros

Detailed parameter settings are crucial for optimizing VFD performance for specific applications. Refer to the comprehensive user guide (if provided separately) for advanced parameter configurations. Basic parameters typically include:

  • Frecuencia de saída máxima
  • Tempo de aceleración/desaceleración
  • Frecuencia nominal do motor
  • Vol. nominal do motortage
  • Corrente nominal do motor

Usa o PROG e FUNC/DATA buttons along with the Up/Down arrows to navigate and modify parameters.

6. Mantemento

Un mantemento regular garante a lonxevidade e o funcionamento fiable do seu variador de frecuencia.

  • Limpeza: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth. Do not use liquid cleaners.
  • Ventilación: Ensure the cooling fan and ventilation holes are unobstructed for proper heat dissipation.
  • Conexións: Comprobe periodicamente todas as conexións do cableado para comprobar se están ben apertadas e se presentan signos de corrosión.
  • Ambiente: Manter o ambiente de funcionamento dentro dos rangos de temperatura e humidade especificados.
  • Inspección: Inspect the VFD for any physical damage or unusual noises during operation.

7 Solución de problemas

If you encounter issues with your VFD, refer to the following common problems and solutions. For persistent issues, contact VEVOR customer support.

ProblemaCausa posibleSolución
O variador de frecuencia non se acendeNo power supply; loose connections; internal faultCheck power input; verify wiring; contact support
O motor non arrancaIncorrect wiring; VFD in stop mode; fault condition; incorrect parametersVerify motor and VFD wiring; press RUN; check for error codes and reset; review axustes de parámetros
Motor runs erratically or at wrong speedIncorrect frequency setting; motor parameters mismatch; unstable power supplyAdjust speed knob; verify motor parameters (rated frequency, voltage); ensure stable input power
VFD displays error codeSobrecorrente, sobretensióntage, overload, phase loss, etc.Refer to the VFD's specific error code list (if available in full manual); address the underlying cause (e.g., reduce load, check wiring); press STOP/RESET to clear
SobrequecementoBlocked ventilation; excessive ambient temperature; continuous heavy loadClear obstructions from fan/vents; ensure adequate airflow; reduce load or operating time; consider a VFD with higher capacity if consistently overloaded

8. Especificacións

Detailed technical specifications for the VEVOR 2.2 kW Variable Frequency Drive.

VEVOR VFD dimensions and specifications

Image: VEVOR VFD showing physical dimensions and key technical specifications such as model number, horsepower, power, current, input/output voltage, input/output frequency, operating temperature, and net weight.

ParámetroValor
Número de modeloAT1-2200X
Caballos de forza3 HP
Poder2.2 kW
Actual10 A
Vol. De entradatageAC 220-240 V Single Phase
Vol. De saídatageAC 220-240 V Three Phase
Frecuencia de entrada50/60 Hz
Frecuencia de saída0-400 Hz
Temperatura de funcionamento10 °C - 40 °C (50 °F - 104 °F)
Peso neto1.2 kg (2.6 lbs) ± 3%
Dimensións (L x W x H)126 x 125 x 186 mm (4.9 x 5 x 7.3 polgadas)
MaterialAluminium (internal components), High-temperature resistant plastic (casing)
Tipo de visualizaciónLED

9. Garantía e soporte

For warranty information, technical support, or service inquiries, please contact VEVOR customer service. Keep your purchase receipt and product model number handy when contacting support.

You can typically find support contact details on the official VEVOR websitio web ou a través da túa plataforma de compra.

© 2026 VEVOR. Todos os dereitos reservados.