VEVOR KEX-16AC-T01

VEVOR Fuel Transfer Pump 110V 15GPM User Manual

Model: KEX-16AC-T01

1. Introdución

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR 110V 15GPM AC Electric Fuel Transfer Pump. Please read this manual thoroughly before use and retain it for future reference. This pump is designed for transferring gasoline, diesel, kerosene, biodiesel, and ethanol blends.

2. Instrucións de seguridade

AVISO: Failure to follow these safety instructions can result in fire, explosion, electric shock, or serious injury.

  • Always operate the pump in a well-ventilated area.
  • Do not use this pump for transferring water, corrosive chemicals, or highly volatile liquids other than those specified.
  • Ensure all electrical connections are secure and comply with local electrical codes. The pump requires user-supplied wiring to connect to a power source.
  • Wear appropriate personal protective equipment (PPE), including eye protection and gloves, when handling fuels.
  • Keep ignition sources, open flames, and sparks away from the pump and fuel transfer area.
  • Do not operate the pump if any part is damaged or leaking.
  • Desconecte a alimentación antes de realizar calquera mantemento ou servizo.
  • The pump features built-in overheat protection. If the pump stops unexpectedly, allow it to cool down before restarting.

3. Que hai na caixa

Verifique que todos os compoñentes estean presentes e non presenten danos ao desembalar:

  • 1 x Bomba de transferencia de combustible
  • 1 x Auto Shut-Off Fuel Nozzle
  • 1 x 13 ft (4 m) Rubber Outlet Hose
  • 1 x 1-3 ft (530-960 mm) PVC Inlet Hose (Telescoping Suction Pipe)
  • 1 caixa de derivación
  • 1 cinta de PTFE
  • 1 x Adaptador
  • 1 x Adapter Union
  • 2 x Wire Terminals
  • 1 x Manual de usuario (este documento)
VEVOR Fuel Transfer Pump with all included accessories and dimensions

Imaxe: Máis deview of the VEVOR Fuel Transfer Pump and its included accessories, along with key dimensions.

4. Especificacións

Número de modelo KEX-16AC-T01
Marca VEVOR
Caudal 15 GPM (57 L / min)
Voltage / Frecuencia CA 110-120V, 60Hz
Elevación máxima de succión 8 pés (2.4 m)
Max Discharge Lift 37 pés (11.28 m)
Tamaño de entrada 1 inch (25.4 mm) NPT
Tamaño de saída 3/4 inch (19 mm) NPT
Hose Length (Outlet) 13 pés (4 m)
Material Ferro fundido
Dimensións do artigo (L x W x H) 12.99 x 8.86 x 9.65 polgadas (330 x 225 x 245 mm)
Peso neto 32.63 libras (14.8 kg)
Combustibles compatibles Gasoline, Diesel, Kerosene, Biodiesel, Ethanol Blends
Diagram showing max suction lift of 8 ft and max discharge lift of 37 ft, with inlet size 1 inch and outlet size 3/4 inch.

Image: Illustration of the pump's suction and discharge capabilities, including inlet and outlet sizes.

5. Instrucións de configuración

5.1 Montaxe da bomba

  1. The pump is designed for fixed installation, typically on a 2-inch NPT drum opening.
  2. Ensure the mounting surface is stable and capable of supporting the pump's weight and operational forces.
  3. Securely thread the pump's inlet into the drum opening. Use PTFE tape on threads to ensure a leak-free seal.
VEVOR Fuel Transfer Pump mounted on a drum with a 2-inch NPT connection

Image: The fuel transfer pump securely mounted on a fuel drum, highlighting the standard 2-inch NPT connection.

5.2 Conexións de mangueiras

  1. Inlet Hose (Suction Pipe): Connect the telescoping PVC inlet hose to the pump's inlet. Adjust the length of the suction pipe to reach near the bottom of the fuel drum without touching it. Ensure a tight connection to prevent air leaks.
  2. Mangueira de saída: Connect the 13 ft (4 m) rubber outlet hose to the pump's outlet. Secure the auto shut-off fuel nozzle to the other end of the outlet hose. Use PTFE tape on all threaded connections to prevent leaks.

5.3 Conexión eléctrica

IMPORTANTE: This pump does not come with a pre-wired plug. Electrical wiring must be performed by a qualified electrician in accordance with all local and national electrical codes. Incorrect wiring can lead to electric shock, fire, or damage to the pump.

  • Ensure the power source is 110-120V AC, 60Hz.
  • Connect the pump's electrical wires to a suitable power cord using the provided wire terminals and junction box.
  • Asegurar a posta a terra adecuada para evitar riscos eléctricos.
  • The waterproof power switch should be easily accessible.
VEVOR Fuel Transfer Pump installed on a drum in an outdoor setting

Image: The fuel transfer pump ready for operation, demonstrating its robust cast iron construction suitable for outdoor use.

6. Instrucións de funcionamento

6.1 Comprobacións previas á operación

  • Confirm all hose connections are tight and free of leaks.
  • Asegúrese de que a bomba estea ben montada.
  • Verify the power connection is correct and safe.
  • Check that the fuel type in the drum is compatible with the pump.

6.2 Fuel Transfer Process

  1. Insert the auto shut-off fuel nozzle into the receiving tank's fill port.
  2. Turn on the pump using the power switch. The pump will begin transferring fuel.
  3. Monitor the fuel transfer. The auto shut-off nozzle is designed to stop the flow automatically when the receiving tank is full, preventing overfilling and spills.
  4. Once the transfer is complete or the nozzle has shut off, turn off the pump using the power switch.
  5. Carefully remove the nozzle from the receiving tank, allowing any residual fuel to drain.
Close-up of an auto shut-off fuel nozzle with automatic locking mechanism and pressure-sensing port

Imaxe: Detallada view of the auto shut-off fuel nozzle, illustrating its safety features for preventing overfills.

Examples of the fuel transfer pump being used for refueling large ships, heavy trucks, agricultural machinery, and drawing fuel from drums

Image: Various applications of the VEVOR Fuel Transfer Pump, including refueling large vehicles and machinery.

7. Mantemento

7.1 Comprobacións periódicas

  • Inspect hoses and connections for wear, cracks, or leaks before each use. Replace damaged components immediately.
  • Comprobe que o cable de alimentación non teña danos.
  • Ensure the pump's housing is clean and free from debris.

7.2 Limpeza e almacenamento

  • After use, wipe down the pump and nozzle with a clean cloth to remove any fuel residue.
  • Store the pump in a dry, secure location, away from direct sunlight and extreme temperatures.
  • Ensure all fuel is drained from hoses before long-term storage.
Close-up of the VEVOR Fuel Transfer Pump showing the internal motor with built-in overheat protection

Image: The pump's internal motor, featuring built-in overheat protection for extended service life and stable operation.

8 Solución de problemas

Problema Causa posible Solución
A bomba non arranca
  • Sen fonte de alimentación
  • Cableado incorrecto
  • Protección contra sobrecalentamento activada
  • Interruptor danado
  • Comprobe a conexión de enerxía e o interruptor automático.
  • Verify wiring by a qualified electrician.
  • Allow pump to cool down for 15-30 minutes.
  • Ponte en contacto co servizo de atención ao cliente para substituír o interruptor.
Caudal baixo ou nulo
  • Fugas de aire na liña de aspiración
  • Clogged inlet filter or hose
  • Insufficient fuel in drum
  • Excessive lift height
  • Tighten all suction connections.
  • Inspeccionar e eliminar calquera atasco.
  • Refill fuel drum.
  • Ensure operating within specified suction/discharge lift limits.
Fuga de combustible
  • Conexións de mangueira soltas
  • Damaged hose or seal
  • Tighten all connections, apply PTFE tape if necessary.
  • Substitúe os compoñentes danados.

9. Información da garantía

Os produtos VEVOR están deseñados para ser duradeiros e ter un bo rendemento. Para coñecer os termos e condicións específicos da garantía aplicables ao teu produto, consulta a tarxeta de garantía incluída coa túa compra ou visita o sitio web oficial de VEVOR. websitio. Garde o recibo da compra como proba de compra para calquera reclamación de garantía.

10. Atención ao cliente

If you encounter any issues or have questions regarding the VEVOR Fuel Transfer Pump that are not covered in this manual, please contact VEVOR customer support. You can typically find contact information on the VEVOR websitio web ou na embalaxe do produto.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.