This manual provides detailed instructions for the installation, operation, and maintenance of your FACULX W3103 Digital High-Power Temperature Controller. Please read this manual thoroughly before use to ensure proper functionality and safety.
The FACULX W3103 is a versatile digital thermostat designed for precise temperature control in high-power heating applications. It features a wide temperature measurement range, multiple control functions, and flexible power input options.
2. Información de seguridade
WARNING: This device operates with high voltage (AC220V) and high power (5000W). Improper installation or use can result in electric shock, fire, or personal injury. Always follow safety guidelines and consult a qualified electrician if unsure.
- Asegúrese de desconectar a fonte de alimentación antes de calquera instalación, cableado ou mantemento.
- Non utilice o dispositivo en lugares húmidos ou damp ambientes.
- Verify all wiring connections are secure and correct according to the wiring diagram.
- Non exceda a intensidade máxima de corrente de 30 A.
- Manteña o dispositivo lonxe de materiais inflamables.
- Este produto non é un xoguete. Manter fóra do alcance dos nenos.
3. Produto rematadoview
The FACULX W3103 Digital Temperature Controller features a clear digital display, control buttons, and a remote temperature sensor for accurate readings.

Figura 3.1: Fronte view of the FACULX W3103 Digital Temperature Controller with its wired temperature sensor.
Compoñentes clave:
- Pantalla dixital: Shows current temperature, set points, and operational status.
- "Start Setting" Buttons (Up/Down Arrows): Adjust the start temperature.
- "Stop Setting" Buttons (Up/Down Arrows): Adjust the stop temperature.
- "SET" Button: Enters setting mode and confirms selections.
- Sensor de temperatura: External probe for accurate temperature measurement.
- Terminais de cableado: For power input and load output connections.
4. Especificacións
Refer to the table below for detailed technical specifications of the FACULX W3103 (AC220V 5000W) model.

Figura 4.1: Physical dimensions of the temperature controller (96mm x 70mm x 46mm).
| Característica | Especificación |
|---|---|
| Nome do produto | Controlador de temperatura dixital |
| Modelo | W3103 |
| Vol. De entradatage (Current Model) | CA 220 V |
| Output Power (Current Model) | 5000W (Max 30A) |
| Tipo de función | Control de temperatura |
| Tipo de saída | Voltage Saída |
| Tipo de control | Control de posición |
| Entrada de medición | NTC10K / B3435 / L = 1 meter |
| Rango de medición de temperatura | -50 °C a 110 °C |
| Rango de control de temperatura | -19 °C a 99 °C |
| Precisión da medición da temperatura | ± 0.2 °C |
| Control de precisión | 1 °C |
| Dimensións (L x W x H) | 96 mm x 70 mm x 46 mm |
| Material | Plástico, Metal |
5. Configuración e instalación
Careful installation is crucial for the safe and effective operation of the temperature controller. Ensure power is disconnected before proceeding.

Figura 5.1: Detallado view of the controller's wiring terminals and display interface.
Instrucións de cableado:
- Conexión de alimentación: Connect the AC 220V power supply to the designated input terminals. Refer to the diagram on the device for correct polarity and terminal identification.
- Conexión de carga: Connect your heating device (load) to the output terminals. Ensure the load's power consumption does not exceed 5000W or 30A.
- Conexión do sensor: Plug the NTC temperature sensor into its dedicated port. The sensor cable length is 1 meter. Position the sensor in the area where temperature needs to be measured and controlled.
- Montaxe: Mount the controller in a suitable, dry location, away from direct heat sources or excessive moisture. Ensure adequate ventilation.
IMPORTANT: Double-check all wiring before applying power. Incorrect wiring can damage the device or connected equipment and poses a safety risk.
6. Instrucións de funcionamento
Once installed and powered on, the controller will display the current temperature. Follow these steps to set your desired temperature range.

Figura 6.1: Controller display indicating AC220V power input and temperature readings.
Configuración dos parámetros de temperatura:
- Encendido: Connect the device to the AC 220V power supply. The display will show the current temperature measured by the sensor.
- Temperatura inicial establecida:
- Press the "SET" button once. The "Start Setting" value will flash.
- Use the "Start Setting" Up/Down arrow buttons to adjust the desired temperature at which the heating should activate.
- Press "SET" again to confirm and move to the Stop Temperature setting, or wait a few seconds for it to auto-save.
- Temperatura de parada establecida:
- After setting the Start Temperature, the "Stop Setting" value will flash.
- Use the "Stop Setting" Up/Down arrow buttons to adjust the desired temperature at which the heating should deactivate.
- Press "SET" again to confirm and exit setting mode, or wait a few seconds for it to auto-save.
The controller will now maintain the temperature within the set range. If the current temperature falls below the "Start Setting", the heating element will activate. If it rises above the "Stop Setting", the heating element will deactivate.
Advanced Functions (Intermittent Operation, Timed On/Off):
This model supports advanced functions like intermittent operation and timed on/off settings. Specific instructions for these modes are typically accessed by pressing and holding the "SET" button for several seconds to enter a parameter menu. Refer to the on-screen codes and a more detailed functional diagram (if available with the product packaging) for precise configuration of these advanced features.
7. Mantemento
The FACULX W3103 is designed for reliable operation with minimal maintenance. Regular checks can help ensure its longevity and performance.
- Limpeza: Periodically wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Conexións: Annually inspect all wiring connections to ensure they are tight and free from corrosion.
- Sensor: Ensure the temperature sensor is clean and free from debris that could affect its accuracy. Do not bend or damage the sensor cable.
- Ventilación: Ensure the controller's ventilation openings are not obstructed to prevent overheating.
Desconecte sempre a alimentación antes de realizar calquera mantemento.
8 Solución de problemas
If you encounter issues with your temperature controller, refer to the following common problems and solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| A pantalla está desactivada | Sen subministración eléctrica; cableado incorrecto; fusible fundido. | Check power connections; verify wiring; check circuit breaker/fuse. |
| A lectura da temperatura é inexacta | Sensor damaged or improperly placed; sensor cable faulty. | Inspect sensor and cable for damage; reposition sensor; replace sensor if damaged. |
| O dispositivo de calefacción non se acende/apaga | Incorrect temperature settings; faulty wiring to load; load malfunction. | Verify Start/Stop temperature settings; check load wiring; test heating device independently. |
| Controller displays "HHH" or "LLL" | Temperature sensor open circuit (LLL) or short circuit (HHH); temperature out of range. | Check sensor connection; replace sensor if faulty; ensure operating within specified temperature range. |
Se o problema persiste despois de intentar estas solucións, póñase en contacto co servizo de atención ao cliente.
9. Garantía e soporte
This product comes with a standard manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including the warranty period and coverage details.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your retailer or the manufacturer directly. Keep your purchase receipt and product model information handy when contacting support.
Fabricante: FACULX
Número de modelo: W3103 (AC220V 5000W)