EUHOMY OL-A016UC26N4

EUHOMY 2.6kW Portable Spot Cooler

Model: OL-A016UC26N4 - User Manual

1. Introdución

Grazas pola compraasing the EUHOMY 2.6kW Portable Spot Cooler. This manual provides essential information for the safe and efficient operation of your appliance. Please read it thoroughly before use and retain it for future reference.

EUHOMY 2.6kW Portable Spot Cooler

Image 1.1: The EUHOMY 2.6kW Portable Spot Cooler unit.

2. Información de seguridade

To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions when operating this appliance.

  • Asegúrese de que a fonte de alimentación coincida co voltage especificado na etiqueta de clasificación.
  • Non utilice a unidade cun cable ou enchufe danados.
  • Manteña o aparello lonxe da auga e outros líquidos.
  • Do not block air inlets or outlets. Maintain at least 50cm clearance from the front and rear, and 30cm from the sides.
  • Always ensure the exhaust duct is properly installed to vent hot air outside the room.
  • Desconecte a unidade antes de limpala ou realizar calquera mantemento.
  • Este aparello non está pensado para ser usado por persoas con capacidades físicas, sensoriais ou mentais reducidas a menos que estean supervisados.

3. Contido do paquete

Verifica que todos os elementos estean presentes no paquete:

  • Spot Cooler Main Unit (1)
  • Window Panels (4)
  • Exhaust Duct (1)
  • Mangueira de descarga (1)
  • Exhaust Nozzle (1)
  • Duct End Connector (1)
  • Control remoto (1)
  • Manual de usuario (1)
Diagram of EUHOMY Portable Spot Cooler package contents including main unit, window panels, exhaust duct, drain hose, nozzle, duct end, remote, and manual.

Image 3.1: Included components of the EUHOMY Portable Spot Cooler.

4. Características do produto

4.1. Powerful Cooling Performance

The EUHOMY Spot Cooler provides a powerful 2.6kW (60Hz) cooling capacity, capable of lowering room temperature by 5°C within 15 minutes. It is designed for effective cooling in areas up to 10 tatami (approximately 16.5 square meters), making it suitable for living rooms, bedrooms, garages, and warehouses.

Graphic illustrating 2.6kW rapid cooling, suitable for 8-10 tatami, R410A refrigerant, Energy Efficiency Class A, and 2.6kW power.

Imaxe 4.1: Acabadoview of cooling capabilities and specifications.

4.2. Three Operating Modes

This unit offers three versatile operating modes to suit various seasonal needs:

  • Modo de arrefriamento: Provides rapid cooling for hot environments.
  • Modo de deshumidificación: Removes up to 28.98 liters of moisture per day, helping to maintain a comfortable humidity level between 40% and 60% RH, especially useful during rainy seasons.
  • Modo de ventilador: Circulates air with two adjustable fan speeds (Weak/Strong) to provide ventilation.
Graphic showing three modes: Cooling, Dehumidifying, and Fan, with seasonal recommendations.

Image 4.2: Three-in-one functionality for year-round comfort.

4.3. Smart Sleep Mode

The smart sleep mode adjusts the set temperature gradually to ensure comfortable sleep. After 1 hour, the temperature increases by 1°C, and after 2 hours, it increases by another 1°C (total 2°C increase from initial setting). The unit then maintains this temperature, preventing overcooling or overheating during the night. This mode also reduces power consumption by approximately 25% over 8 hours compared to normal operation.

Diagram showing temperature changes in sleep mode: +1°C after 1 hour, +2°C after 2 hours, and a person sleeping comfortably.

Image 4.3: Smart Sleep Mode for optimized overnight comfort and energy saving.

4.4. 24-Hour Timer Function

Set the unit to automatically turn on or off within a 1 to 24-hour period. This feature allows for efficient operation, ensuring the room is cooled before you arrive home or turns off after you leave, saving energy.

5. Configuración e instalación

The EUHOMY Spot Cooler is designed for easy installation without requiring professional construction. Follow these steps for setup:

5.1. Posicionamento da unidade

Place the unit on a flat, stable surface. Ensure there is adequate clearance around the unit for proper airflow (at least 50cm from front/rear, 30cm from sides). The unit is equipped with casters for easy movement between rooms.

5.2. Window Panel Installation

Assemble the window panels according to your window size. The panels are adjustable from 50cm to 135cm to fit various window types (sliding or vertical sash windows). Secure the panels in the window frame using screws. The 2026 model includes four window panels for improved adaptability and sealing.

Detailed steps for installing the window panel kit, showing assembly, placement in window, connecting exhaust duct to unit, and connecting duct to window panel. Includes window type diagrams and panel length combinations.

Image 5.1: Window panel installation guide.

5.3. Exhaust Duct Connection

Attach the exhaust duct to the unit's exhaust outlet and then connect the other end to the window panel. Ensure a secure connection to prevent hot air from re-entering the room. The improved exhaust duct design in the 2026 model enhances sealing performance by 50%.

6. Funcionamento

The unit can be operated using the touch control panel on top of the unit or the included remote control.

Image showing the unit's touch control panel and the remote control with various buttons for power, mode, temperature, fan speed, timer, and sleep mode.

Image 6.1: Control panel and remote control layout.

6.1. Acendido/apagado

Prema o botón de acendido (運転入/切) no panel de control ou no mando a distancia para acender ou apagar a unidade.

6.2. Selección de modo

Prema o botón Modo (モード) to cycle through Cooling (冷房モード), Dehumidifying (除湿モード), and Fan (送風モード) modos.

6.3. Axuste de temperatura

In Cooling mode, use the Up (+) e abaixo (-) buttons to set the desired temperature between 16°C and 32°C.

6.4. Axuste da velocidade do ventilador

In Fan mode, press the Fan Speed button (風量) to select between Weak () and Strong () airflow.

6.5. Configuración do temporizador

Preme o botón Timer (タイマー機能) to set the auto-on or auto-off time in 1-hour increments, from 1 to 24 hours.

6.6. Sleep Mode Activation

Press the Sleep button (睡眠) to activate the smart sleep mode for quiet and comfortable overnight operation.

6.7. Louver Adjustment

Manually adjust the vertical louvers to direct the airflow as desired.

7. Mantemento

Regular maintenance ensures optimal performance and longevity of your spot cooler.

7.1. Drenaxe

The unit is designed with a non-drainage system for cooling mode, where condensed water is evaporated and expelled with the exhaust air. However, in high humidity conditions or during dehumidifying mode, significant water accumulation may occur. Connect the included drain hose to the drainage port for continuous drainage to prevent overflow.

7.2. Limpeza de filtros

Periodically clean the air filter to maintain air quality and unit efficiency. Refer to the detailed instructions in the printed user manual for filter removal and cleaning procedures.

7.3. Limpeza exterior

Limpe o exterior da unidade cun suave, damp pano. Non use produtos químicos agresivos ou produtos de limpeza abrasivos.

8 Solución de problemas

Antes de contactar co servizo de atención ao cliente, consulta os seguintes problemas e solucións comúns:

ProblemaCausa posibleSolución
A unidade non se acendeSen subministración de enerxía; cable de alimentación non conectado; disyuntor saltado.Comprobe a conexión de alimentación; Restableza o disxuntor.
Refrixeración insuficienteWindows/doors open; Exhaust duct not properly installed; Air filter dirty; Room size too large.Close windows/doors; Ensure duct is sealed; Clean air filter; Use in recommended room size.
Fuga de augaDrain hose not connected or blocked; Water tank full (if applicable).Connect drain hose; Clear any blockages; Ensure continuous drainage in high humidity.
A unidade é ruidosaUnit not on a flat surface; Air filter dirty; Normal operating sound.Place on a flat surface; Clean air filter; Some operating noise is normal for portable ACs.

9. Especificacións

CaracterísticaDetalle
MarcaEUHOMY
Número de modeloOL-A016UC26N4
Capacidade de refrixeración2.3kW (50Hz) / 2.6kW (60Hz)
Área de aplicación8-10 Tatami
Rango de configuración de temperatura16°C a 32°C
Fonte de alimentación100 V (50/60 Hz)
Consumo de enerxía de refrixeración750W (50Hz) / 800W (60Hz)
Capacidade deshumidificadora28.98 l/día
Nivel de ruído55dB (Operating Sound: 43dB)
RefrixeranteR-410A
Dimensións da unidade (P x L x A)30.3 x 28.95 x 67.3 cm
Peso unitarioAprox. 20.5 kg
Tipo de controladorControl táctil
Table of specifications for 8000BTU and 9000BTU models, including power, cooling capacity, power consumption, current, refrigerant, product weight, and unit dimensions.

Imaxe 9.1: Especificacións e dimensións detalladas do produto.

10. Garantía e soporte

10.1. One-Year Quality Guarantee

This product comes with a one-year quality guarantee from the date of purchase. Please retain your proof of purchase for warranty claims.

Graphic indicating a one-year quality guarantee.

Image 10.1: One-Year Quality Guarantee.

10.2. Atención ao cliente

For any questions regarding the product or delivery, please contact our customer support. You can reach us via email or inquiry. For inquiries after purchase, navigate to 'Order History' > 'Problem with order' > 'View profile' > 'Ask a question' or refer to the contact information in the Japanese instruction manual.

Graphic indicating Japanese customer support available via email and inquiry.

Image 10.2: Customer support contact options.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.