SINOTIMER TM929AK

Sinotimer Digital Analogue DIN Module Time Switch Instruction Manual

Models: TM929AKL (16A), TM929BKL (30A)

1. Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of your Sinotimer Digital Analogue DIN Module Time Switch. This device is designed for industrial applications, offering precise 24-hour programmable timing with a large LCD display and backlight functionality.

2. Funcións do produto

  • Clock display (24-hour format).
  • Programmable Timer with up to 96 ON/OFF programs per day.
  • Backlight feature: The backlight illuminates when the timer is off and automatically disappears after 5 seconds.

3. Especificacións

ParámetroValor
Números de modeloTM929AKL (16A), TM929BKL (30A)
Fonte de alimentación85~265 VCA, 50/60 Hz
Max. Current of Output Load16A / 30A (depending on model)
ProgramasUp to 96 ON/OFF per day
Rango de configuración15 minutos a 24 horas
Minimum Setting Intervalminutos 15
MostrarLCD con retroiluminación
Dimensións86.5 mm x 36 mm x 68.5 mm
InstalaciónCarril DIN de 35 mm
BateríaTM929AKL (16A): Replaceable CR2032; TM929BKL (30A): Non-replaceable internal battery
Consumo de enerxía<5VA
Black-out (Power Reserve)90 días
CertificaciónCE

Nota: The TM929AKL (16A) model features a replaceable CR2032 battery, while the TM929BKL (30A) model has a non-replaceable internal battery. Wiring diagrams differ between models.

Dimensions of the Sinotimer DIN module time switch, showing height 8.7cm, width 3.5cm, and depth 6.5cm with a 4.7cm front panel depth.
Figura 1: Dimensións do produto

4. Configuración

4.1 Instalación

The time switch is designed for mounting on a standard 35mm DIN rail. Ensure the mounting location is dry, well-ventilated, and free from excessive vibrations or extreme temperatures.

De volta view of the Sinotimer time switch showing the DIN rail mounting clip.
Figure 2: DIN Rail Mounting Mechanism

4.2 Cableado

AVISO: All wiring should be performed by a qualified electrician and in accordance with local electrical codes. Ensure power is disconnected before attempting any wiring.

The timer has terminals for Line (L), Neutral (N), and output contacts (NO, NC, Common). Refer to the diagrams below for typical wiring configurations.

Wiring diagram for direct connection of a light bulb to the Sinotimer time switch. Line (L) and Neutral (N) are connected to terminals 1 and 2. The load (light bulb) is connected between terminal 3 (NO) and Neutral (N).
Figure 3: Direct Wiring Diagram (e.g., for a light bulb)
Wiring diagram for connecting the Sinotimer time switch with an external contactor to control a higher load. Line (L) and Neutral (N) are connected to terminals 1 and 2. The timer's NO contact (terminals 3 and 5) controls the coil of an external contactor (e.g., ABB AX-09-30-10). The load is then connected through the contactor's power contacts.
Figure 4: Wiring Diagram with Contactor (for higher loads)

4.3 Acendido inicial

Once wired correctly, apply power to the device. The LCD will illuminate and display the current time. If the display is blank, check the power supply and, for the 16A model, ensure the CR2032 battery is correctly installed.

5. Instrucións de funcionamento

The timer features a MENU button, UP/DOWN arrow buttons, an OK button, and a Reset (Res) button.

Close-up of the Sinotimer time switch's control panel, showing the MENU, UP, DOWN, OK, and Reset buttons, along with the LCD display.
Figura 5: Panel de controlview

5.1 Axuste da hora actual

  1. Prema o botón "MENÚ".
  2. Use the 'UP' and 'DOWN' arrow buttons to adjust the hour and minute.
  3. Prema "Aceptar" para confirmar cada configuración.
  4. Press 'MENU' again to return to the clock display.

5.2 Programación de ciclos de acendido/apagado

The timer supports up to 96 ON/OFF programs. Each program can be set for specific days of the week.

  1. Press the 'MENU' button to enter programming mode. The display will show '00:00' or a program number.
  2. Use 'UP' and 'DOWN' to set the desired ON time (hour and minute). Press 'OK' to confirm.
  3. Next, set the desired OFF time (hour and minute). Press 'OK' to confirm.
  4. Use 'UP' and 'DOWN' to select the days of the week for this program (e.g., Mon-Fri, Sat-Sun, or individual days). Press 'OK' to confirm.
  5. Repita os pasos 2-4 para programas adicionais.
  6. Press 'MENU' to exit programming mode and save settings.

5.3 Anulación manual

To manually switch the timer's output, press the 'OK' button. This will cycle through the modes: ON (always on), AUTO (follows programmed schedule), and OFF (always off).

Video 1: Demonstrating manual override and setting intervals. Press 'OK' to switch working mode (ON/AUTO/OFF). Press 'MENU' to set intervals, then 'OK' to confirm, and 'MENU' to return to clock status.

6. Mantemento

6.1 Battery Replacement (TM929AKL 16A only)

The TM929AKL (16A) model uses a replaceable CR2032 battery. If the display becomes dim or the time settings are lost frequently during power outages, the battery may need replacement. Carefully open the battery compartment and replace the CR2032 battery, ensuring correct polarity. The TM929BKL (30A) model has a non-replaceable internal battery.

6.2 Coidados xerais

Keep the device clean and dry. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents. Ensure the protective cover is closed to prevent dust and moisture ingress.

7 Solución de problemas

  • A pantalla está en branco: Check the main power supply. For the 16A model, check the CR2032 battery.
  • Timer not switching: Verify wiring connections are secure and correct. Ensure the timer is in 'AUTO' mode. Check that programs are set correctly and not conflicting.
  • Hora incorrecta: Reset the timer using the 'Res' button and reprogram the current time.
  • Programs not executing: Ensure the timer is in 'AUTO' mode. Check that the ON/OFF times and days are correctly set.

7.1 Reinicio do temporizador

To perform a full reset, press the 'Res' button (usually a small recessed button requiring a pointed object like a pen tip). This will clear all settings and return the timer to its factory default state. You will need to reprogram the current time and all desired ON/OFF cycles.

8. Consellos de usuario

  • For precise control, utilize the full capacity of 96 ON/OFF programs to manage complex schedules.
  • When setting intervals, remember the minimum programmable interval is 15 minutes.
  • Always double-check your wiring before applying power to prevent damage to the unit or connected appliances.

9. Garantía e soporte

For technical assistance, warranty claims, or further information, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.


Guía de funcionamento do interruptor temporizador dixital SINOTIMER TM929AK

Guía de funcionamento do interruptor temporizador dixital SINOTIMER TM929AK

0:24 • 720×720 • funcionamento

Documentos relacionados - TM929AK

Preview Interruptor temporizador dixital LCD HD SINOTIMER serie TM928: manual de usuario e especificacións
Guía completa dos interruptores temporizadores dixitais da serie SINOTIMER TM928, que abrangue as características, as especificacións, a configuración e o cableado de modelos como TM919, TM920, TM928, TM928S, TM928R e TM929.
Preview Temporizador dixital SINOTIMER TM-630A/TM-630S: características e especificacións
Especificacións técnicas detalladas e características dos temporizadores dixitais programables SINOTIMER TM-630A e TM-630S, incluíndo a fonte de alimentación, o rango de temporización, as dimensións e o cableado.
Preview Temporizador programable semanal Sinotimer TM-616: especificacións e funcionamento
Información detallada sobre o temporizador programable semanal Sinotimer TM-616, incluíndo especificacións, funcións dos botóns, dimensións, diagramas de cableado e liña de produtos. Inclúe programación de 7 días e capacidade de conmutación de 30 A.
Preview Interruptor horario dixital SINOTIMER TM-610 para carril DIN: manual de usuario e especificacións
Especificacións detalladas, diagramas de cableado e instrucións de funcionamento para o interruptor horario dixital SINOTIMER TM-610, deseñado para montaxe en carril DIN.
Preview SINOTIMER TM929: Guía del Temporizador Analógico Diario de 24 Horas
Explore o temporizador analóxico diario SINOTIMER TM929 de 24 horas. Este manual proporciona información detallada sobre as súas características, especificacións técnicas e diagramas de cableado para unha fácil instalación e operación.
Preview Manual do usuario do interruptor temporizador programable 3 en 1 SINOTIMER serie TM920
Manual de usuario completo para o interruptor temporizador programable 3 en 1 SINOTIMER serie TM920, con programación de 7 días, funcións de pulso e conta atrás. Aprende a configurar a data, a hora, os modos de control e a configuración de festivos.