1. Introdución

The SINOTIMER STVP-932 is an advanced three-phase intelligent voltage protector designed to provide comprehensive protection for electrical equipment against various power supply anomalies. This device features a digital display for real-time voltage monitoring and offers adjustable parameters for over-voltage, baixo voltage, voltage unbalance, phase sequence, zero line break, and phase failure protection. Its self-resetting capability ensures continuous operation and enhanced system reliability.

2. Información de seguridade

  • A instalación e o mantemento só deben ser realizados por electricistas cualificados.
  • Asegúrese de desconectar a fonte de alimentación principal antes de realizar calquera traballo de instalación, cableado ou mantemento.
  • Verifique que o voltage and current ratings of the protector match your application requirements.
  • Do not operate the device if it shows signs of damage.
  • Siga sempre os códigos e as normativas eléctricas locais.

3. Produto rematadoview

3.1 Características

  • Sobrevoltage protección
  • Sub-voltage protección
  • Voltage display (separate ABC phase volt measurement)
  • Trifásico voltage unbalance protection
  • Phase sequence protection (reverse phase protection)
  • Zero line break protection
  • Protección contra fallos de fase
  • Adjustable over-voltagvalor de protección
  • Adjustable over-voltage valor de recuperación
  • Adjustable over-voltagtempo de acción de protección electrónica
  • Adjustable under-voltagvalor de protección
  • Adjustable under-voltage valor de recuperación
  • Adjustable under-voltagtempo de acción de protección electrónica
  • Adjustable 3-phase voltage unbalance protection value
  • Adjustable 3-phase voltage unbalance protection action time
  • Adjustable delay time after power-on
  • Adjustable fault recovery delay time
  • Reset mode selection
  • Fault inquiry function
  • Factory data reset function

3.2 Compoñentes

The STVP-932 features a clear digital display, control buttons for setting parameters, and robust terminals for secure wiring.

Fronte view of the SINOTIMER STVP-932 voltage protector
Figura 1: Fronte view of the STVP-932 showing digital display and control buttons.
Close-up of the STVP-932 digital display showing individual phase voltages
Figure 2: Digital display indicating voltage readings for phases A, B, and C.

4. Especificacións

ParámetroValor
Número de modeloSTVP-932
Fonte de alimentación3*230V / 400V AC 50/60Hz
Max. Loading Power50A, 63A, or 80A (model dependent)
SobrevoltagRango de protección electrónico221V~300V-OFF (Adjustable, Default: 280V)
Sobrevoltage Recovery Range220V~299V (Default: 250V)
Sobrevoltage Action Time0.1~10 seconds (Adjustable, Default: 0.2s)
Sub-voltagRango de protección electrónico150V~219V-OFF (Adjustable, Default: 160V)
Dimensións (L x W x H)72 x 65 x 80 mm
MaterialABS + compoñentes electrónicos
CorBranco
Dimensional drawing of the STVP-932 voltage protector
Figure 3: Dimensions of the STVP-932 device.

5. Configuración e instalación

The STVP-932 is designed for DIN rail mounting within an electrical enclosure. Ensure proper ventilation and clearance around the device.

5.1 Montaxe

Attach the protector to a standard 35mm DIN rail by snapping the clips on the back of the device onto the rail. Ensure it is securely fastened.

Lado view of the STVP-932 showing DIN rail mounting clips
Figura 4: Lateral view illustrating the DIN rail mounting mechanism.

5.2 Diagrama de cableado

Follow the wiring diagram carefully to connect the STVP-932 to your three-phase electrical system. The device has 'IN' terminals for incoming power (L1, L2, L3, N) and 'OUT' terminals for protected outgoing power (L1, L2, L3, N).

Wiring diagram for SINOTIMER STVP-932 showing connections to power switch and air circuit breaker
Figure 5: Wiring diagram for the STVP-932, showing connections to a power switch and an air circuit breaker. Ensure correct phase (L1, L2, L3) and neutral (N) connections for both input and output.

Pasos de conexión:

  1. Connect the incoming three-phase power supply (L1, L2, L3, N) to the 'IN' terminals of the STVP-932.
  2. Connect the 'OUT' terminals (L1, L2, L3, N) of the STVP-932 to the load or downstream circuit protection devices (e.g., air circuit breaker).
  3. Asegúrate de que todas as conexións estean ben axustadas e seguras para evitar contactos soltos e sobrequecemento.

6. Instrucións de funcionamento

6.1 Pantalla dixital

A pantalla dixital mostra o volume en tempo realtage readings for each phase (A, B, C). In normal operation, it cycles through these readings or displays the current status.

6.2 Configuración de parámetros

Use the 'SET' button to enter the parameter setting mode. The 'Up' and 'Down' arrow buttons are used to navigate through parameters and adjust their values. Press 'SET' again to confirm a setting and move to the next parameter, or to exit the setting mode.

Adjustable parameters include:

  • Sobrevoltage protection value (Uvo)
  • Sobrevoltage valor de recuperación
  • Sobrevoltagtempo de acción de protección electrónica
  • Sub-voltage protection value (Uve)
  • Sub-voltage valor de recuperación
  • Sub-voltagtempo de acción de protección electrónica
  • Trifásico voltage unbalance protection value
  • Trifásico voltage unbalance protection action time
  • Delay time after power-on
  • Fault recovery delay time

6.3 Reset Mode Selection

The device supports different reset modes. Consult the English manual included in the package for detailed instructions on selecting the appropriate reset mode for your application.

6.4 Fault Inquiry and Factory Reset

The device allows for fault inquiry to review past protection events. A factory data reset option is also available to restore all parameters to their default settings.

7 Solución de problemas

This section provides guidance on common issues you might encounter with the STVP-932.

ProblemaCausa posibleSolución
Device trips frequentlyVoltage fluctuations (over/under voltage), phase unbalance, incorrect settings.Check power supply stability. Adjust protection thresholds (Uvo, Uve) and action times. Verify load balance across phases.
Sen pantalla/Sen alimentaciónNo input power, incorrect wiring, internal fault.Ensure main power is on. Check input wiring (L1, L2, L3, N). If wiring is correct and power is present, contact support.
Device does not resetContinuous fault condition, incorrect reset mode setting.Ensure the fault condition has cleared. Check the configured reset mode and recovery delay time.
Vol. incorrectotage lecturasLoose connections, sensor issue.Verify all wiring connections are secure. If the issue persists, contact support.

8. Mantemento

  • Regularly inspect the device for any physical damage or signs of overheating.
  • Manteña o dispositivo limpo e libre de po e residuos. Use un pano seco e suave para limpar.
  • Comprobe periodicamente todas as conexións do cableado para asegurarse de que permanezan axustadas e seguras.
  • Do not attempt to open or repair the device yourself, as this may void any warranty and pose a safety risk.

9. Consellos de usuario

Based on common usage and feedback, here are some tips for optimizing your experience with the STVP-932:

  • Configuración inicial: When first installing, set the protection values slightly wider than your expected normal operating range to avoid nuisance tripping, then fine-tune as needed.
  • Seguimento: Regularly check the digital display to understand the typical voltage behavior of your system, which can help in setting optimal protection parameters.
  • Atraso de recuperación: Utilize the fault recovery delay time setting to prevent rapid on/off cycling of equipment during intermittent power issues, protecting sensitive loads.

10. Garantía e soporte

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the SINOTIMER customer service department. Keep your purchase receipt and product model number handy for faster assistance.

Documentos relacionados - STVP-932

Preview SVP-916 Sobrevol. intelixentetagManual de instrucións do protector de corrente límite e
Manual de instrucións para o sobrevolante intelixente SINOTIMER SVP-916tage, baixo voltage protector de sobrecorrente para sistemas monofásicos de CA de 230 V. Detalla as características, os parámetros e os métodos de configuración para a protección de equipos eléctricos.
Preview Manual de instrucións do interruptor intelixente WiFi SINOTIMER
Manual de instrucións completo para o interruptor intelixente WiFi SINOTIMER, que detalla a configuración da rede a través da aplicación Graffiti Smart, os procedementos de desvinculación e reinicio do dispositivo, o estado da luz indicadora, a visualización do consumo de electricidade e a configuración do sobrevol.tage, subvoltage, e axustes de protección contra sobrecorrentes.
Preview Manual do usuario de SINOTIMER SVP719: Vol.tage Protector, medidor de enerxía e monitor de consumo de enerxía
Manual de usuario completo para o SINOTIMER SVP719, que detalla as súas características como sobrevolante/subvolante axustabletagprotector de sobretensións, protector de sobretensións, relé límite de sobrecorrente e un contador de enerxía en vatios/kWh para monitorizar o consumo de enerxía.
Preview Manual de instrucións do interruptor de medición de carril guía SINOTIMER serie DDS6619
Manual de instrucións para os interruptores de medición de tipo carril guía SINOTIMER serie DDS6619. Detalla as especificacións técnicas, o cableado, o control da aplicación a través de Smart Life/Tuya, as instrucións de funcionamento e as precaucións de seguridade para a monitorización intelixente da enerxía.
Preview Interruptor horario dixital SINOTIMER TM-610 para carril DIN: manual de usuario e especificacións
Especificacións detalladas, diagramas de cableado e instrucións de funcionamento para o interruptor horario dixital SINOTIMER TM-610, deseñado para montaxe en carril DIN.
Preview SINOTIMER TM929: Guía del Temporizador Analógico Diario de 24 Horas
Explore o temporizador analóxico diario SINOTIMER TM929 de 24 horas. Este manual proporciona información detallada sobre as súas características, especificacións técnicas e diagramas de cableado para unha fácil instalación e operación.