LAUNCH CNC605A

LAUNCH CNC605A Injector Cleaner & Tester User Manual

Model: CNC605A

1. Introdución

The LAUNCH CNC605A Injector Cleaner & Tester is an advanced electromechanical product designed for cleaning and testing fuel injectors. Utilizing ultrasonic cleaning technology and precise fuel pressure control, this equipment simulates engine working conditions to effectively clean and test GDI, EFI, and SFI injectors. It also supports on-vehicle cleaning of injectors and the fuel supply system.

LAUNCH CNC605A Injector Cleaner and Tester main unit
Figure 1: LAUNCH CNC605A Injector Cleaner & Tester Main Unit

2. Características clave

  • Limpeza ultrasónica potente: Offers complete cleaning to injectors/pump, removing carbon deposits.
  • Stable Testing Pressure: Microcomputer-controlled stable testing pressure with a large adjustable range.
  • Operación automática: Supports automatic cleaning, testing injectors, and real-time monitoring of dynamic values via microcomputer control and LCD display.
  • Automatic Fuel Draining: Features automatic fuel draining through preset programs for specific test items.
  • Deseño humanizado: System pressure can be quickly restored to default values.
  • Interface de usuario: LCD display for operation details and touch button controls.
Diagram showing LAUNCH CNC605A features including ultrasonic cleaning, sealing test, fuel injection quantity test, uniformity and sprayability test, no disassembly needed, and automatic mode.
Figura 2: Máisview of CNC605A Features and Capabilities

3. Especificacións

3.1. Condicións de traballo

  • Temperatura: -10℃ a +40℃
  • Humidade relativa: <85 %
  • Intensity of Outer Magnetic Field: <400Am
  • Seguridade: No naked flame within 2m of the equipment.

3.2. Especificacións técnicas

ParámetroValor
Nome da marcaLANZAMIENTO
Nome do modeloCNC605A
Tipo de elementoAnalizador de motores
Fonte de alimentación da unidade principalAC220V~50/60Hz
Ultrasonic Cleaner Power60 W
Presión de combustible0.1-10 bar
Entrada de aire5-8 bar
Rango de RPM100-9900 rpm (Step: 100 rpm)
PW Range0.5-25.0 ms (Step: 0.1 ms)
Intervalo de temporizador1-30 min
Capacidade do tanque~3 l
Peso do elemento20 kg
Altura do elemento41.5 polgadas
Ancho do elemento21.5 polgadas
Lonxitude do elemento58.4 polgadas
Certificación de probas externasCE
MaterialPLACTIS
Versión de softwareMÁIS NOVO
Versión de hardwareMÁIS NOVO
Inclúense as baterías?Non
Actualización de softwareNon
Image showing various accessories and adapters included with the CNC605A injector cleaner and tester.
Figure 3: Included Accessories and Adapters

4. Configuración

Before operating the LAUNCH CNC605A, ensure the following setup steps are completed:

  1. Desembalaxe: Carefully remove the main unit and all accessories from the packaging. Inspect for any damage.
  2. Colocación: Place the unit on a stable, level surface in a well-ventilated area, away from any naked flames or sources of ignition.
  3. Conexión de alimentación: Connect the main unit to an AC220V~50/60Hz power supply. Ensure the voltage cumpre cos requisitos da unidade.
  4. Conexión de subministración de aire: Connect an air supply providing 5-8 bar pressure to the designated air inlet port.
  5. Injector Preparation: Before placing injectors into the ultrasonic bathtub, clean their exterior thoroughly with a suitable cleaning liquid to remove dirt.
Close-up of the CNC605A control panel and injector setup, showing injectors mounted for testing.
Figure 4: Injector Setup on the Main Unit

5. Funcionamento

The CNC605A offers various functions for comprehensive injector cleaning and testing. Follow these general steps for operation:

5.1. General Operating Procedure

  1. Limpeza inicial: After external cleaning, place the injectors into the ultrasonic bathtub. Ensure the cleaning fluid does not exceed the connection port of the pulse line.
  2. Limpeza por ultrasóns: Activate the ultrasonic system. This process dislodges carbon build-up and other particles from inside the injectors.
  3. Mounting Injectors: Fix the cleaned injectors onto the main machine's test bench.
  4. Test Liquid Addition: Add the appropriate test liquid to the glass tubes, ensuring it reaches at least half the tube's height.
  5. Performing Tests: Select and perform the desired tests from the available functions.
  6. Retesting: After cleaning cycles, return the injectors to the flow bench for retesting of all functions to verify performance improvement.

5.2. Specific Test Functions

  • Limpeza por ultrasóns: Removes carbon deposition from injectors.
  • Uniformity / Sprayability Test: Checks the uniformity of injection amount and monitors spray patterns using backlight.
  • Proba de fuga: Evaluates injector sealing and dribbling conditions under system pressure.
  • Injecting Volume Test: Measures the injecting amount over 15 seconds of constant injection.
  • Auto. Test: Runs a preset program of tests for injectors.
  • On-vehicle Cleaning: Performs cleaning to remove carbon deposition directly on the vehicle.
  • Configuración: Allows configuration of system parameters, including language.
  • Consulta: Provides access to equipment usage information.
  • Información: Displays hardware and software version details.

6. Mantemento

Proper maintenance ensures the longevity and optimal performance of your CNC605A Injector Cleaner & Tester.

  • Limpeza regular: Keep the exterior of the machine clean. Wipe down surfaces with a soft, damp pano.
  • Cleaning Fluid Management: After ultrasonic cleaning, the remaining cleaning fluid can be recycled for future use. Dispose of spent fluids according to local regulations.
  • Test Liquid Management: Regularly check the level and condition of the test liquid. Replace or replenish as needed.
  • Injector Cleaning: Always clean the outside of injectors before placing them in the ultrasonic bathtub to prevent contamination of the cleaning fluid.
  • Almacenamento: When not in use, store the unit in a clean, dry environment within the specified temperature range.

7 Solución de problemas

This section addresses common issues you might encounter with your CNC605A unit.

Issue: Unit does not power on.
  • Ensure the power cable is securely connected to both the unit and a functional AC220V~50/60Hz power outlet.
  • Verify that the power switch on the unit is in the "ON" position.
  • Check the power source for proper voltage and functionality.
Issue: Ultrasonic cleaning is ineffective.
  • Ensure the ultrasonic bathtub is filled with the correct cleaning liquid to the appropriate level.
  • Verify that the injectors were externally cleaned before being placed in the bathtub.
  • Check the ultrasonic power setting.
Issue: Inaccurate test results.
  • Ensure the test liquid is clean and at the correct level in the glass tubes.
  • Verify that the air inlet pressure is within the specified range (5-8 bar).
  • Check for proper sealing of injectors on the test bench to prevent leaks during testing.
  • Recalibrate the unit if necessary (refer to advanced settings or contact support).
Issue: Display language needs to be changed.
  • Navigate to the "Setting" menu on the LCD display to adjust the system language.

8. Consellos de usuario

  • Voltage Compatibilidade: The unit operates on AC220V. If your region uses 110V, a suitable voltage converter will be required to ensure proper operation and prevent damage.
  • Configuración de idioma: The display language can be changed via the 'Setting' menu. Check for available language options to suit your preference.

9. Garantía e soporte

The LAUNCH CNC605A Injector Cleaner & Tester comes with a commitment to quality and customer support.

  • Soporte técnico de por vida: LAUNCH provides lifetime technical support for this product.
  • Substitución gratuíta: The product may be eligible for free replacement for 365 days from the date of purchase. Please refer to your purchase agreement for specific terms and conditions.
  • For any technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your authorized LAUNCH dealer or customer service.

Documentos relacionados - CNC605A

Preview Manual do usuario do probador de baterías Bluetooth LAUNCH BST360
Manual de usuario do comprobador de baterías Bluetooth LAUNCH BST360, no que se detallan as súas características para o estado da batería, o sistema de carga e as probas de inicio do sistema, xunto con información sobre a conexión e a garantía.
Preview Manual da caixa de baterías LAUNCH X-431 GDS: Guía de probas de baterías para automóbiles
Manual de usuario completo para a caixa de baterías LAUNCH X-431 GDS, que detalla os procedementos de proba de baterías de automóbiles, as precaucións operativas e as especificacións técnicas para uso profesional.
Preview Manual do usuario de LAUNCH Creader Professional CRP123
Este manual do usuario ofrece instrucións completas para a ferramenta de diagnóstico para automóbiles LAUNCH Creader Professional CRP123, que abarcan as súas características, funcionamento, procedementos de diagnóstico, configuración, actualizacións e resolución de problemas.
Preview Guía de inicio rápido de LAUNCH Creader Professional 123X
Unha guía de inicio rápido para o LAUNCH Creader Professional 123X, que detalla a configuración inicial, a carga e os procedementos de diagnóstico básicos.
Preview Manual do usuario da ferramenta de diagnóstico LAUNCH: características, funcionamento e mantemento
Este manual de usuario completo para a ferramenta de diagnóstico LAUNCH (ID da FCC: XUJWO0805A) guía aos usuarios a través das súas amplas funcións, que inclúen o diagnóstico intelixente e local do vehículo, unha ampla gama de funcións de servizo como reinicios e calibracións, diagnóstico remoto, actualizacións de software e compatibilidade con varios módulos como ADAS e TPMS. Ofrece información esencial sobre configuración, funcionamento e seguridade para profesionais da automoción e usuarios avanzados de bricolaxe.
Preview Substitución do motor de 5ª xeración do Audi: instrucións de funcionamento e sincronización de datos antirroubo
Este documento proporciona instrucións operativas detalladas para substituír un motor Audi de 5.ª xeración. Abarca o proceso de lectura, carga e sincronización de datos antirroubo mediante ferramentas de diagnóstico LAUNCH como PADIII, PAD V e X431 G3, garantindo a substitución e a codificación axeitadas da ECU.