1. Introdución
The Y&H Hybrid Solar Inverter is an advanced all-in-one power solution designed for both on-grid and off-grid applications. It is available in 4.2kW (24V) and 6.2kW (48V) models, integrating a 120A MPPT solar charger, a pure sine wave inverter, and an intelligent battery management system to deliver stable and efficient energy conversion for your home or business.
Key features include advanced battery-free operation, support for offline firmware updates via the COMM port, and an enhanced 27A PV input current. It is engineered to provide zero electromagnetic interference, making it safe for sensitive household electronics. The Y&H Hybrid Inverter is an ideal choice for users looking to establish or expand their energy storage systems with reliability and flexibility.

Figure 1: Y&H Hybrid Inverter overview, highlighting 60-500V PV input, DC 24V/48V battery voltage, 120A MPPT charging, AC 220V input/output, and 24 months warranty.
2. Características
- Inversor solar de onda sinusoidal pura (capacidade de conectar/desconectar da rede).
- Dual communication ports for Battery communication and Wi-Fi communication.
- Vol. de entrada fotovoltaica altatagrango e (60~500VDC).
- Deseño intelixente de carga da batería para optimizar a duración da batería.
- Offline firmware upgrade capability through COMM port.
- Inverter-lithium battery communication status displayed directly on the LCD interface.
- Lithium battery information display available on the mobile application.
- Factor de potencia de saída 1.0.
- Ability to run the inverter without a connected battery.
- Activación automática da batería de litio integrada.
- Integrated MPPT Solar charge controller.
- Kit antipo integrado para unha maior durabilidade en ambientes agresivos.
- Dual AC output functionality.
- Corrente de entrada fotovoltaica máxima: 27 A.
- Improved user experience in battery-free mode for powering loads.
- Wi-Fi & GPRS connectivity available for iOS and Android applications.
- One-key restoration to factory settings.
3. Especificacións técnicas
The following tables detail the technical specifications for the Y&H Hybrid Inverter models YH4.2K24500EU and YH6.2K48500EU.
| Parámetro | YH4.2K24500EU | YH6.2K48500EU |
|---|---|---|
| Xeral | ||
| Fase | Monofásico | |
| Dimensión (D*W*H) | 423 * 344 * 113 mm | |
| Dimensións do paquete (P*A*A) | 500 * 415 * 180 mm | |
| Temperatura de funcionamento | -10 ℃ ~ 50 ℃ | |
| Grid-Tie Operation - PV Input (DC) | ||
| Potencia máxima de entrada PV | 6200 W | 8000 W |
| DC nominal Voltage | 360VDC | |
| Max DC Voltage | 500VDC | |
| Iniciación Voltage | 60VDC | |
| Vol. de alimentación inicialtage | 90VDC | |
| MPPT Voltage Alcance | 60~450VDC | |
| Corriente de entrada máxima | 27A | |
| Grid-Tie Operation - AC Output | ||
| Taxa de potencia de saída | 4200 W/4200 VA | 6200 W/6200 VA |
| Vol. De saída nominaltage | 220/230 / 240VCA | |
| Vol. De saídatage Alcance | 195-253 VCA | |
| Corrente nominal de saída | 18.2A | 27.0A |
| Factor de potencia | > 0.99 | |
| Eficiencia | ||
| Max Conversion Efficiency (DC-AC) | 98 % | |
| Off-Grid, Hybrid Operation - PV Input (DC) | ||
| Max DC Voltage | 60/500VDC | |
| Iniciación Voltage | 60VDC | |
| Vol. de alimentación inicialtage | 90VDC | |
| MPPT Voltage Alcance | 60VDC-450VDC | |
| Corriente de entrada máxima | 27A | 27A |
| Off-Grid, Hybrid Operation - AC Output | ||
| Vol. De saída nominaltage | 220/230 / 240VCA | |
| Vol. De saídatage Alcance | 195-253 VCA | |
| Corrente nominal de saída | 18.2A | 27.0A |
| Entrada AC | ||
| Vol. De entrada CAtage Alcance | 90-280 V CA ou 170-280 V CA | |
| Máxima corrente de entrada AC | 24.7A | 36.4A |
| Saída do modo batería (CA) | ||
| Vol. De saída nominaltage | 220/230 / 240VCA | |
| Eficiencia | 94 % | |
| Batería e cargador | ||
| Vol. Nominaltage | 24VDC | 48VDC |
| Corrente de carga solar máxima | 120A | |
| Máxima corrente de carga AC | 100A | |
| Corrente de carga máxima (total) | 120A | |
| Interface | ||
| Porto de comunicación | RS232/RS485/WIFI/BMS | |

Figure 2: Detailed technical specifications for the Y&H Hybrid Inverter, covering electrical parameters, dimensions, and environmental conditions.
4. Port Introduction
Familiarize yourself with the various ports and indicators on the Y&H Hybrid Inverter for proper installation and operation.

Figura 3: Parte dianteira e traseira view of the Y&H Hybrid Inverter with numbered labels for each port and indicator.
- Pantalla LCD: Mostra o estado operativo e a configuración.
- Status indicator: Indicates the current operational status of the inverter.
- Charging indicator: Shows the battery charging status.
- Fault indicator: Illuminates when a fault is detected.
- Function buttons: Used for navigating menus and adjusting settings.
- Power on/off switch: Controls the main power to the inverter.
- AC input: Connection point for grid/utility power.
- Main output: Primary AC output for loads.
- Second output: Secondary AC output for non-critical loads (4.2KW model setting range 40.0V to 46.0V).
- Entrada de batería: terminais de conexión para o banco de baterías.
- PV input: Connection terminals for solar panel array.
- Anti dust kit: Protective cover for ports.
- Battery communication/RS-485 port: For communication with compatible battery systems.
- Wi-Fi communication/RS-232 port: For Wi-Fi module connection and serial communication.

Figure 4: Diagram illustrating the Main Out and Second Out ports, highlighting the Smart Dual Output Protection feature. This feature intelligently isolates non-critical loads on the Main OUT port during deep discharge, preserving power for essential equipment on the Secondary OUT port.
5. Configuración e instalación
Proper installation is crucial for the safe and efficient operation of your hybrid inverter. Please follow these guidelines carefully.
5.1 Diagrama de cableado
The following diagram illustrates the typical wiring connections for the Y&H Hybrid Inverter, including connections for solar panels, generator, mains power, main output, secondary output, and battery.

Figure 5: Detailed wiring diagram for the Y&H Hybrid Inverter system, showing connections for solar panels, generator, mains power, main output, secondary output, and battery. Includes cable and breaker recommendations.
- Vol. de entrada de CA máxtage: 300 VCA
- Corrente de carga máxima: 120Amp
- Suggested cable for AC: 12 AWG
- Recommended breaker for AC: 32A
- Potencia de saída de CA: 4200 W
- Saída CA Voltage: 230 VCA
- Potencia fotovoltaica: 6200W (for 4.2KW model) / 8000W (for 6.2KW model)
- Max PV Circuit Open Voltage: 500 V
- PV MPPT VoltagRango: 60 V-450 V CC
- Vol. Inicialtage (carga inicial): > 90 V
- Suggested cable for PV: 12 AWG
- It is recommended to connect solar panels in series.
- Tipo de batería: Batería de chumbo-ácido (selado, AGM, de xel, inundado) e de litio
- Batería voltage: 24V (for 4.2KW model) / 48V (for 6.2KW model)
- Tamaño do cable da batería: 2 AWG
- Cable da batería: 25 mm²
- Nota: The output of the inverter is 230V. For 110V appliances, a converter (not included) is required.
5.2 Battery Compatibility and Battery-Free Operation
The inverter supports a wide range of battery types and can also operate without a connected battery.

Figure 6: Illustration of inverter dimensions and explanation of battery-free operation, compatible with 48V lead-acid and lithium batteries.
Funcionamento sen batería: The inverter can supply power directly to loads from either the PV array or AC grid without requiring a connected battery. This provides flexibility and can be useful in certain system configurations.
Activación da batería de litio: When a Li-ion battery is in sleep mode, a dual-trigger mechanism activates it automatically. Access to either mains power or photovoltaic power will initiate the Li-ion battery's activation.
Tipos de batería compatibles: AGM, GEL, Flooded, Lithium, SLD, and User-defined battery types are supported.
6. Instrucións de funcionamento
6.1 Charger Priority Settings
The inverter allows you to configure the charging source priority based on your energy management needs. There are four selectable 4-stage charger priorities:

Figure 7: Diagram showing selectable 4-stage charger priority options and configurable 3-output source priority options for the inverter.
- Utility/AC Power: Charge battery first from utility power.
- Enerxía solar: Charge battery first from solar power.
- Solar + Servizos públicos: Charge battery at the same time from both solar and utility.
- Só solar: Charge battery only from solar power.
6.2 Output Source Priority Settings
You can also configure the priority of power sources for your loads. There are three configurable output source priorities:
- Utility Source: Power load as first priority from utility.
- Enerxía solar: Power load first from solar power.
- Solar + Battery: Power load at the same time from solar and battery.
6.3 Monitorización e control a través da aplicación SmartESS
The Y&H Hybrid Inverter can be monitored and controlled remotely using the SmartESS App, available for both iOS and Android devices. A built-in Wi-Fi transmitter allows you to access your inverter's data from anywhere with an internet connection. (Note: Wi-Fi module may need to be purchased separately, and registration is required).

Figure 8: Illustration of the SmartESS App interface for monitoring and controlling the hybrid inverter from various locations (home, store, office).
7. Mantemento
Regular maintenance helps ensure the longevity and optimal performance of your Y&H Hybrid Inverter.
- Limpeza: Periodically clean the exterior of the inverter to prevent dust buildup. The built-in anti-dust kit helps protect internal components, but external cleaning is still recommended.
- Ventilación: Ensure that the inverter's ventilation openings are clear and unobstructed to allow for proper airflow and heat dissipation.
- Conexións: Regularly check all wiring connections (PV, battery, AC input/output) to ensure they are secure and free from corrosion. Loose connections can lead to poor performance or safety hazards.
- Actualizacións de firmware: Keep the inverter's firmware updated to benefit from the latest features and performance improvements. Offline updates are supported via the COMM port.
- Saúde da batería: If using batteries, monitor their health and ensure they are maintained according to the manufacturer's recommendations.
8 Solución de problemas
This section provides general guidance for common issues. For detailed troubleshooting, refer to the comprehensive user manual (PDF).
8.1 Common Indicators and Their Meanings
- Indicador de estado: Check the status indicator (Figure 3, item 2) for the inverter's operational state. Refer to the manual for specific light patterns and their meanings.
- Indicador de carga: The charging indicator (Figure 3, item 3) shows if the battery is charging. If it's not lit when expected, check PV input or AC input connections.
- Indicador de falla: If the fault indicator (Figure 3, item 4) is lit, a system error has occurred. Consult the LCD display for error codes and refer to the detailed manual for troubleshooting steps.
8.2 Comprehensive Protection Features
The inverter is equipped with multiple protection mechanisms to ensure safe operation and prevent damage to the unit and connected devices.

Figure 9: Visual representation of the comprehensive protection features, including Short Circuit, Over-Load, Over Current, Backfill, Over Voltage, Sobretemperatura, BaixoVoltage, and Over Charge Protection.
- Protección contra curtocircuítos: Evita danos por curtocircuítos.
- Protección contra sobrecarga: Shuts down if output load exceeds capacity.
- Protección contra sobrecorriente: Protects against excessive current draw.
- Backfill Protection: Prevents reverse current flow.
- Máis de Voltage Protección: Safeguards against high voltage entrada/saída.
- Protección contra sobretemperatura: Shuts down if internal temperature is too high.
- Baixo o voltage Protección: Protects batteries from deep discharge.
- Protección contra sobrecarga: Evita a sobrecarga da batería.
If any protection mechanism is triggered, the inverter may shut down or display a fault code. Always refer to the full manual for specific fault code interpretations and corrective actions.
9. Consellos de usuario
- Optimal PV Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to optimize charging efficiency.
- Tamaño do cable: Always use the recommended cable gauges for PV, battery, and AC connections to minimize energy loss and ensure safety.
- Xestión de carga: When operating in battery-free mode or with limited battery capacity, prioritize essential loads to maximize system uptime.
- Monitorización Wi-Fi: Utilize the SmartESS App for remote monitoring to keep track of your system's performance and quickly identify any issues.
- Consideracións ambientais: While the inverter has an anti-dust kit, installing it in a clean, well-ventilated area away from direct sunlight and moisture will extend its lifespan.
10. Garantía e soporte
The Y&H Hybrid Inverter comes with a 24 meses de garantía desde a data de compra, que cobre defectos de fabricación e avarías de funcionamento en condicións de uso normal. Conserve o comprobante de compra para reclamacións de garantía.
For detailed warranty terms, technical support, or advanced troubleshooting, please refer to the official user manual PDF. You can access the PDF manual at: Y&H Hybrid Inverter User Manual (PDF).
For further assistance, please contact Y&H customer support through their official channels.