Hobbywing 12L Brushless Water Pump

Hobbywing 12L Brushless Water Pump Instruction Manual

Model: 12L Brushless Water Pump

1. Introdución

This manual provides essential information for the safe and efficient operation, setup, and maintenance of your Hobbywing 12L Brushless Water Pump. This high-performance peristaltic pump is designed for demanding applications such as agricultural sprayers and drones, offering precise flow control and robust construction. Please read this manual thoroughly before installation and use.

2. Información de seguridade

  • Desconecte sempre a alimentación antes de realizar calquera instalación, mantemento ou resolución de problemas.
  • Ensure all electrical connections are secure and properly insulated to prevent short circuits and electric shock.
  • Operate the pump within its specified voltage range (14-18S LiPo, 44-81V) to prevent damage.
  • Avoid direct contact with moving parts during operation.
  • Do not immerse the pump in water beyond its IP66 rating. While water-resistant, it is not designed for continuous submersion.
  • Use appropriate personal protective equipment (PPE) when handling chemicals or operating the pump in hazardous environments.
  • Manter fóra do alcance dos nenos.

3. Produto rematadoview

The Hobbywing 12L Brushless Water Pump is a compact and powerful unit featuring a brushless motor for efficiency and longevity. It supports both CAN and PWM control for flexible integration into various systems. Its peristaltic design ensures consistent flow and prevents fluid contamination of internal components.

Características principais:

  • Brushless Motor: For high efficiency and extended lifespan.
  • Dual Control Modes: Supports CAN and PWM for versatile integration.
  • High Flow Rate: Up to 12L/min (2 channels, 6L/min each).
  • Ancho Voltage Range: Compatible with 14-18S LiPo batteries (44-81V).
  • IP66 Protection: Resistant to dust and powerful water jets.
  • Peristaltic Design: Ensures precise dosing and prevents fluid contact with pump mechanics.

Compoñentes:

The pump unit includes the main pump body, integrated brushless motor, control electronics, and connection cables for power and signal. Mounting brackets are typically integrated into the design for easy installation.

Arriba abaixo view of the Hobbywing 12L Brushless Water Pump with wiring connections.
Figura 1: De arriba abaixo view of the pump, showing the main body and wiring.
Lado view of the Hobbywing 12L Brushless Water Pump with wiring.
Figura 2: Lateral view of the pump, highlighting its compact design.

4. Especificacións

ParámetroValor
Usando Voltage14-18S LiPo (44-81V)
Potencia nominal150 W
Maximum Opening Flow12L/min (2 channels, 6L/min each)
Minimum Opening Flow0.6 l/min
Canles2
Grao de protecciónIP66
Peso778 g
Size (excluding wire)151 x 75 x 124 mm
Inner Diameter of Inlet Water Pipe8 mm
Inner Diameter of Outlet Water Pipe8 mm
Fixed PWM Throttle Travel1050-1950 μs
PWM Level3.3 V/5 V

5. Configuración

5.1 Montaxe

Securely mount the pump to a stable surface on your agricultural sprayer or drone using appropriate fasteners. Ensure the mounting location allows for proper hose routing and access for maintenance. The pump should be mounted in an orientation that minimizes strain on the water pipes and electrical connections.

Parte superior angular view of the Hobbywing 12L Brushless Water Pump, showing mounting points.
Figura 3: Parte superior inclinada view, illustrating potential mounting points.

5.2 Water Pipe Connections

  1. Connect the inlet water pipe (8mm inner diameter) from your fluid reservoir to the designated inlet port(s) on the pump.
  2. Connect the outlet water pipe(s) (8mm inner diameter) from the pump to your spray nozzles or distribution system.
  3. Ensure all pipe connections are tight and leak-free. Use hose clamps if necessary to prevent accidental disconnections or leaks during operation.

5.3 Conexións eléctricas

  1. Conexión de alimentación: Connect the main power cable of the pump to a compatible 14-18S LiPo battery or power source. Observe correct polarity (red for positive, black for negative).
  2. Control Signal Connection:
    • Control PWM: Connect the PWM signal wire to your flight controller or control unit. Ensure the PWM level is 3.3V or 5V and the throttle travel is within 1050-1950μs.
    • CAN Control: If using CAN, connect the CAN bus wires (CAN-H and CAN-L) to your CAN-enabled flight controller or control system. Refer to your flight controller's manual for specific CAN bus setup.
  3. Double-check all electrical connections before applying power.

6. Instrucións de funcionamento

6.1 Comprobación previa á operación

  • Verify all connections (power, signal, water pipes) are secure.
  • Ensure the fluid reservoir contains sufficient liquid.
  • Check for any obstructions in the water pipes or nozzles.

6.2 Arranque da bomba

Once all connections are verified and the system is ready, apply power to the pump. The pump will typically enter a standby mode. Use your flight controller or control unit to send the appropriate PWM or CAN command to start the pump.

6.3 Axuste do caudal

The flow rate can be adjusted via the PWM signal (throttle travel 1050-1950μs) or CAN commands from your control system. Experiment with different signal values to achieve the desired flow for your application.

6.4 Parar a bomba

Send a stop command via PWM or CAN from your control unit. Disconnect the main power source after use.

7. Mantemento

7.1 Limpeza regular

  • After each use, especially when spraying chemicals, flush the pump and lines with clean water to prevent residue buildup and corrosion.
  • Limpe o exterior da bomba cun anuncioamp pano. Non use produtos químicos ou disolventes agresivos.

7.2 Inspección

  • Periodically inspect water pipes for cracks, kinks, or blockages.
  • Check electrical cables for any signs of wear, fraying, or damage.
  • Ensure mounting screws remain tight.

7.3 Almacenamento

Store the pump in a clean, dry environment away from direct sunlight and extreme temperatures. If storing for an extended period, ensure the pump and lines are thoroughly cleaned and dry.

8 Solución de problemas

ProblemaCausa posibleSolución
A bomba non arrancaNo power; incorrect voltage; faulty signal connection; pump damaged.Check power supply and connections; verify voltage is within 14-18S; inspect signal wiring; contact support if pump is damaged.
Sen fluxo de fluídoEmpty reservoir; clogged pipes/nozzles; air in the system; pump not primed.Refill reservoir; clear obstructions; ensure system is free of air; prime the pump if necessary.
Inconsistent flowPartial blockage; fluctuating power/signal; worn peristaltic tubing.Check for partial blockages; ensure stable power and control signal; inspect peristaltic tubing for wear.
Ruído/vibración excesivoLoose mounting; foreign object in pump; motor issue.Tighten mounting screws; inspect pump for foreign objects (after disconnecting power); contact support if motor issue suspected.

9. Consellos de usuario

  • For optimal performance and longevity, always use clean fluids and regularly flush the system.
  • When integrating with a flight controller, ensure the PWM or CAN settings are correctly configured to match the pump's requirements.
  • Consider using a filter on the inlet line to prevent debris from entering the pump and clogging nozzles.
  • Regularly check the condition of the peristaltic tubing, as it is a wear item and may need replacement over time depending on usage and fluid type.

10. Garantía e soporte

Para obter información sobre a garantía, asistencia técnica ou consultas sobre o servizo, póñase en contacto co seu vendedor ou directamente co fabricante. Garde o comprobante de compra para reclamacións de garantía.

Documentos relacionados - 12L Brushless Water Pump

Preview Hobbywing P50M Industrial Multirotor Power System User Manual
Comprehensive user manual for the Hobbywing P50M industrial-grade multirotor brushless power system, detailing specifications, installation, operation, firmware upgrades, troubleshooting, and safety precautions.
Preview Manual de usuario do Hobbywing XRotor Pro X13-18S
Manual de usuario do sistema de alimentación sen escobillas Hobbywing XRotor Pro X13-18S, que detalla as súas características, especificacións, instalación, uso e mantemento.
Preview HOBBYWING X8-G2 Drone Propulsion System User Manual
User manual for the HOBBYWING X8-G2 Drone Propulsion System, detailing specifications, installation, operation, and maintenance for agricultural plant protection drones. Features IPX6 rating, FOC algorithm, and CAN/Cyphal communication.
Preview Manual do usuario de HOBBYWING XRotor Pro X8: Sistema de alimentación para drons agrícolas
Manual de usuario completo para o sistema de alimentación sen escobillas HOBBYWING XRotor Pro X8, que detalla as especificacións, a instalación, o funcionamento e a resolución de problemas para aplicacións de drons agrícolas.
Preview Hobbywing DataLinkBox G3 User Manual - ESC Debugging and Data Tool
User manual for the Hobbywing DataLinkBox G3, a communication device for brushless propulsion system debugging, data collection, storage, and transmission. Features include Bluetooth connectivity, throttle output, and LED status indicators for ESC parameter adjustment and firmware upgrades.
Preview Hobbywing QUICRUN WP 10BL120 G2 & 8BL150 G2 Brushless ESC User Manual
Comprehensive user manual for Hobbywing QUICRUN WP 10BL120 G2 and 8BL150 G2 Brushless Electronic Speed Controllers, covering features, specifications, connections, setup, programming, and troubleshooting for RC vehicles.