AOLON W3002 Microcomputer Temperature Controller

Especificacións técnicas
| Especificación | Detalles |
|---|---|
| Nome do produto | Microcomputer Temperature Controller (XH-W3002) |
| Rango de medición | -50°C to 110°C (-50°C to 100°C model variation) |
| Rango de control | -50°C to 110°C (-50°C to 100°C model variation) |
| Precisión da medición da temperatura | ± 0.2 °C |
| Precisión de control de temperatura | ± 0.1 °C |
| Entrada de medición | NTC10K L=1m waterproof probe |
| Input Power Options | 12V / 24V / 220V AC/DC |
| Opcións de potencia de saída | 120W (12V) / 240W (24V) / 1500W (220V) |
| Tipo de saída | Saída directa |
| Capacidade de saída | Máximo 10 A |
| Distancia do orificio de instalación | 73mm (Hole size: 4mm) |
| Dimensións | 60 mm × 45 mm × 31 mm |
Configuración e uso rápido
- Connect the temperature sensor: use the supplied NTC10K waterproof probe (L=1m).
- Provide power using one supported option: 12V/24V/220V AC/DC.
- Set start temperature (P0): press the Configuración button to enter the menu (default to P0), press Configuración again, then use Up/Abaixo to set the desired start temperature.
- Set stop temperature (P1): in the menu, use Up/Abaixo to select P1, press Configuración again, then adjust with Up/Abaixo.
- (Optional) Calibrate temperature (P2): select P2, press Configuración to enter calibration, then set the offset value using Up/Abaixo.
- (Optional) Set delayed start (P3): select P3 and set the delay time (minutes) using Up/Abaixo (recommended 3–6 minutes for compressor-based refrigeration; otherwise leave at 0).
Wiring Diagrams & Safety Information
12V / 24V Connection Way
Aviso: 12V/24V power supplies must use a stable DC power source.
220V Connection Way
Aviso: This model is designed with direct output power. Exercise extreme caution when connecting the electricity. Ensure the load is connected to the output terminal port before powering up to prevent potential output short circuit ignition or sparks.
Settings Parameter Menu
| Código | Descrición | Rango de configuración | Por defecto de fábrica |
|---|---|---|---|
| P0 | Temperatura de inicio | -50 a 110 °C | 00°C |
| P1 | Temperatura de parada | -50 a 110 °C | 00°C |
| P2 | Corrección de temperatura | -10 a 10 °C | 0°C |
| P3 | Delay to start | 0 a 10 minutos | minutos 0 |
Parameter Configurations & Functions
P0: Start-up Temperature Setting
Preme o Configuración button to enter the internal menu. The display will default to P0. Preme o Configuración button once more, then use the Up e Abaixo buttons to set your desired start temperature.
Preme o Configuración button to enter the internal menu. When
P0 is displayed, use the Up or Abaixo botóns para seleccionar P1. Preme o Configuración button again, and adjust the target stop temperature using the Up e Abaixo botóns.Preme o Configuración button to enter the internal menu, then switch to
P2 usando o Up or Abaixo botóns. Preme o Configuración button again to calibrate. Use the Up e Abaixo buttons to enter the offset value.Calibration Formula: Detected Temperature + Calibration Temperature = Actual Temperature
- If the detected temperature is 0.5°C higher than the actual temperature: Set P2 to -0.5°C
- If the detected temperature is 1.0°C lower than the actual temperature: Set P2 to 1.0°C
P3: Delayed Start Setting
Preme o Configuración button to enter the internal menu and switch to P3 usando o Up or Abaixo botóns. Preme o Configuración button again and set the delay time in minutes using the Up or Abaixo botóns.
Nota: This function is typically used for compressor-based refrigeration systems (like refrigerators or freezers) to protect the motor. A delay of 3 to 6 minutes is recommended. If you are not controlling a compressor, leave this set to 0.
Modos de funcionamento
Modo de calefacciónRegra:Start-up Temperature (P0) < Stop Temperature (P1) The system automatically determines it is in heating mode when P0 is configured lower than P1.
Exampo Escenario:
Control a water heater to turn off when the temperature reaches 50°C and restart heating when the temperature drops back down to 40°C.
- Verify that the heating rule is met: Start-up (40°C) is less than Stop (50°C).
- Preme o Configuración button, enter the menu, select
P0, and adjust the value to 40°C. - Preme o Configuración button, enter the menu, select
P1, and adjust the value to 50°C.
Modo de arrefriamentoRegra: Start-up Temperature (pø) > Stop Temperature (Pl). The system automatically determines it is in cooling mode when P0 is configured higher than P1.
Exampo Escenario:
Control a cabinet radiator to turn on when temperatures reach 30°C and stop cooling once the temperature drops to 26°C.
- Verify that the cooling rule is met: Start-up (30°C) is greater than Stop (26°C).
- Preme o Configuración button, enter the menu, select
P0, and adjust the value to 30°C. - Preme o Configuración button, enter the menu, select
P1, and adjust the value to 26°C.
Resolución de problemas
Common Fault: Incorrect Settings
If you set your temperature values upside down (e.g., configuring heating parameters with P0 > P1), the output indicator light will remain off and the connected load will not work. Check the temperature values in your P0 e P1 settings if the system is unresponsive.
With the controller powered on, press and hold both the Up e Abaixo buttons simultaneously for approximately 3 seconds. Once the digital tube displays
888, The controller will automatically return to real-time temperature detection, indicating a successful factory reset.- Display “LLL”: Indicates a temperature sensor probe failure. Please inspect, repair, or replace the waterproof probe.
- Display “HHH”: Indicates that the ambient temperature has exceeded the controller’s detection range. Relocate the unit to an appropriate environment.
Documentos/Recursos
![]() | W3002 Microcomputer Temperature Controller |
Referencias
- Manual de usuariomanual.tools