1. Introdución
The Extech DO600 Waterproof ExStik II Dissolved Oxygen Meter is designed for precise measurement of dissolved oxygen levels. It displays oxygen concentration as a percentage of saturation (0 to 200%) or as a concentration in parts per million (ppm) or milligrams per liter (mg/L) (0 to 20.00 ppm/mg/L). Key features include adjustable altitude compensation, adjustable salinity compensation, and an analog bargraph for trend indication. This manual provides instructions for the proper setup, operation, and maintenance of your DO600 meter.
2. Contido do paquete
Comprobe que todos os artigos estean presentes e en bo estado ao desembalar:
- Extech DO600 Dissolved Oxygen Meter
- Electrodo de disolución óptica
- Protective Sensor Cap
- Spare Membrane Cap
- Electrolyte Solution
- Four 3V CR-2032 Batteries (pre-installed or included separately)
- 48-inch (1.2m) Neck Strap

Figure 1: Extech DO600 meter with its accessories, including the electrode, caps, electrolyte, and neck strap.
3. Compoñentes do medidor

Figura 2: Fronte view of the Extech DO600 meter.
- Pantalla LCD: Shows dissolved oxygen readings, temperature, and other indicators.
- MODE/HOLD Button: Toggles between measurement modes and holds the current reading.
- CAL/RECALL Button: Initiates calibration and recalls stored data.
- Botón ON/OFF: Powers the meter on or off.
- Electrodo: Sensor for dissolved oxygen measurement.
- Protective Sensor Cap: Covers and protects the electrode.
4. Configuración
4.1. Instalación da batería
The DO600 meter uses four 3V CR-2032 batteries. These are typically pre-installed. If replacement is necessary:
- Twist off the battery compartment cap located at the top of the meter.
- Remove the old batteries, noting their polarity.
- Insert new CR-2032 batteries with the correct polarity.
- Securely replace the battery compartment cap to maintain the waterproof seal.
4.2. Electrode Preparation
Before first use or after prolonged storage, the DO electrode requires preparation:
- Unscrew the protective sensor cap from the electrode.
- Fill the spare membrane cap with the provided electrolyte solution. Ensure no air bubbles are trapped.
- Carefully screw the membrane cap onto the electrode, ensuring the membrane is taut and free of wrinkles.
- Allow the electrode to stabilize for approximately 15-30 minutes in the electrolyte solution before calibration.
5. Instrucións de funcionamento
5.1. Acendido/apagado
Preme o ON/OFF button to power the meter on or off.
5.2. Calibración
Regular calibration ensures accurate readings. Calibrate the meter in air-saturated water or a known standard solution.
- Ensure the electrode is prepared as described in Section 4.2.
- Immerse the electrode in air-saturated water (e.g., tap water stirred vigorously for several minutes) or a DO standard solution.
- Manteña premido o CAL / RECALL botón ata que apareza "CAL" na pantalla.
- The meter will automatically recognize the calibration point and adjust. Wait for the reading to stabilize and for the calibration indicator to confirm completion.
5.3. Toma de medicións
To measure dissolved oxygen:
- Encender o contador.
- Immerse the electrode into the sample solution. Ensure the membrane is fully submerged and free of air bubbles.
- Gently stir the electrode in the sample to ensure proper flow across the membrane.
- Wait for the reading on the LCD display to stabilize. The display will show both dissolved oxygen and temperature.
- Preme o MODO / HOLD button to cycle between % saturation and ppm (mg/L) readings.
- To hold a reading, briefly press the MODO / HOLD botón. Prema de novo para soltar.

Figure 3: The Extech DO600 meter being used to measure dissolved oxygen in a laboratory.
5.4. Altitude Compensation
Dissolved oxygen saturation levels are affected by altitude. The DO600 allows for manual adjustment:
- Refer to the meter's full instruction manual for specific steps to enter and adjust altitude compensation (0 to 20,000 feet in 1,000 ft. increments).
5.5. Salinity Compensation
Salinity also influences dissolved oxygen levels. The DO600 provides adjustable salinity compensation:
- Consult the meter's comprehensive manual for detailed instructions on setting salinity compensation (0 to 50 ppt).
6. Mantemento
6.1. Electrode Cleaning and Storage
To maintain electrode performance:
- Enxágüe o electrodo con auga destilada despois de cada uso.
- If the membrane becomes fouled, gently clean it with a soft cloth or cotton swab. Replace the membrane cap if it is damaged or heavily contaminated.
- When storing, ensure the protective sensor cap is filled with electrolyte solution to keep the membrane hydrated.
6.2. Substitución da batería
Substitúa as baterías cando apareza o indicador de batería baixa na pantalla. Consulte a Sección 4.1 para obter instrucións de instalación da batería.
7 Solución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| O medidor non se acende | Dead batteries; Incorrect battery installation | Substituír as baterías; comprobar a polaridade das baterías |
| Lecturas inexactas ou inestables | Electrode not calibrated; Fouled membrane; Air bubbles on membrane; Insufficient electrolyte | Perform calibration; Clean/replace membrane; Remove air bubbles; Refill electrolyte |
| No reading displayed | Electrode not connected properly; Damaged electrode | Ensure electrode is securely attached; Replace electrode if damaged |
8. Especificacións
| Parámetro | Valor |
|---|---|
| Modelo | C600 |
| Dissolved Oxygen Range (Concentration) | 0 a 20.00 ppm (mg/L) |
| Dissolved Oxygen Range (Saturation) | 0 a 200.0 % |
| Rango de temperatura | Not explicitly stated for display, but upper rating is 50 ℃ |
| Compensación de Altitude | 0 to 20,000 feet (in 1,000 ft. increments) |
| Compensación de salinidade | 0 a 50 ppt |
| Fonte de enerxía | Four 3V CR-2032 batteries |
| Dimensións | 6.9 x 1.6 x 1.4 polgadas (17.5 x 4.1 x 3.6 cm) |
| Peso do elemento | 3.87 onzas (0.11 kg) |
| Clasificación impermeable | Yes (implied by "Waterproof ExStik II") |

Figure 4: Physical dimensions of the Extech DO600 meter. Note: The image shows 7.7 inches, while product specifications state 6.9 inches. Refer to the latest product documentation for precise measurements.
9. Vídeos de produtos
Non se atoparon vídeos oficiais do vendedor para este artigo nos datos proporcionados.
10. Garantía e soporte
For warranty information, technical support, or to purchase accessories and replacement parts, please refer to Extech's official website or contact their customer service department. You can find more information on the Tenda Extech en Amazon.