Buscador 80.01.0.240.0000

Finder 80.01.0.240.0000 Multifunction Time Delay Relay User Manual

Modelo: 80.01.0.240.0000

1. Introdución

This manual provides essential information for the safe and efficient use of the Finder 80.01.0.240.0000 Multifunction Time Delay Relay. This device is designed for precise timing control in various applications, offering multiple functions and a wide time range. Please read this manual thoroughly before installation and operation.

2. Configuración e instalación

Proper installation is crucial for the reliable operation of the time delay relay. Ensure all power is disconnected before proceeding with installation.

2.1 Produto superadoview

Fronte view of Finder 80.01.0.240.0000 Time Delay Relay

Figura 1: Fronte view of the Finder 80.01.0.240.0000 Time Delay Relay, showing the time setting dial, function selector, and terminal markings.

En ángulo view of Finder 80.01.0.240.0000 Time Delay Relay

Figura 2: En ángulo view of the Finder 80.01.0.240.0000 Time Delay Relay, illustrating its compact design and DIN rail compatibility.

2.2 Montaxe

The Finder 80.01.0.240.0000 relay is designed for DIN rail mounting. Securely attach the relay to a standard 35mm DIN rail in an appropriate enclosure, ensuring adequate ventilation.

2.3 Cableado

Refer to the wiring diagrams below for correct electrical connections. Ensure all connections are tight and conform to local electrical codes.

Wiring diagrams for Finder 80.01.0.240.0000 Time Delay Relay

Figure 3: Wiring diagrams for the Finder 80.01.0.240.0000 Time Delay Relay. The left diagram shows basic connection for terminals A1, A2, 15, 16, 18. The right diagram includes an external control input 'S' at terminal B1.

  • Power Supply (A1, A2): Conecte o control voltage (12-240V AC/DC) to terminals A1 and A2.
  • Control Input (B1): For functions requiring an external control signal, connect the signal to terminal B1.
  • Output Contacts (15, 16, 18): These are changeover contacts. Terminal 15 is the common, 16 is normally closed (NC), and 18 is normally open (NO). Connect your load circuit to these terminals.

2.4 Configuración inicial

Before applying power, set the desired time range and function using the rotary selectors on the front of the unit. The time range can be set up to 24 hours. Consult the product datasheet for specific function definitions.

3. Instrucións de funcionamento

Once installed and configured, the relay operates automatically based on the selected function and time settings.

3.1 Selección de funcións

Rotate the function selector switch to choose the desired timing mode (e.g., ON-delay, OFF-delay, flasher). Refer to the product's technical specifications for a complete list of available functions and their descriptions.

3.2 Axuste do tempo

Use the time setting dial to adjust the delay period within the selected time range. The dial typically has markings for common time values. Fine-tuning may be required for precise applications.

3.3 Indicadores de estado

The relay features an LED indicator. This LED typically blinks during the timing phase and illuminates steadily when the output relay is energized, providing visual feedback on the operational status.

4. Mantemento

The Finder 80.01.0.240.0000 time delay relay is designed for long-term, maintenance-free operation. However, periodic checks can ensure optimal performance.

  • Limpeza: Keep the relay free from dust and debris. Use a dry, soft cloth for cleaning. Do not use solvents or abrasive cleaners.
  • Comprobacións de conexión: Inspeccione periodicamente as conexións dos cables para garantir que estean seguras e libres de corrosión.
  • Condicións ambientais: Asegúrese de que o ambiente de funcionamento se manteña dentro dos rangos de temperatura e humidade especificados para evitar fallos prematuros.

5 Solución de problemas

If the relay does not operate as expected, perform the following basic checks:

  • Sen enerxía: Verify that the control voltage is correctly applied to terminals A1 and A2 and is within the specified range (12-240V AC/DC). Check fuses or circuit breakers.
  • Temporalización incorrecta: Confirm that the time range and time setting dials are correctly configured for the desired delay.
  • Saída sen conmutación: Check the load connections to terminals 15, 16, and 18. Ensure the load is within the relay's contact rating (16A 250V~). Verify the selected function is appropriate for the application.
  • Control Signal Issue: If using an external control signal (B1), ensure it is correctly applied and within specifications.
  • Indicador LED: Observe the LED behavior. A continuously off LED may indicate no power, while an unexpected blinking pattern might suggest a fault or incorrect function selection.

If issues persist after these checks, consult a qualified electrician or contact Finder technical support.

6. Especificacións técnicas

The following table details the key technical specifications for the Finder 80.01.0.240.0000 Multifunction Time Delay Relay.

CaracterísticaEspecificación
Número de modelo80.01.0.240.0000
MarcaBuscador
Vol. Subministracióntage12-240V AC / DC
Valoración do contacto de saída16A 250V~
Intervalo de tempoUp to 24 hours (max)
Número de configuracións6 (Functions)
MaterialPolicarbonato
CorBranco
Dimensións do produto (P x A x A)3.5" x 0.69" x 2.39" (88.8 mm x 17.5 mm x 60.8 mm)
Peso do elemento4.54 g

6.1 Dimensións

Dimensional drawing of Finder 80.01.0.240.0000 Time Delay Relay

Figure 4: Dimensional drawing of the Finder 80.01.0.240.0000 Time Delay Relay, showing measurements in millimeters for installation planning.

7. Garantía e soporte

7.1 Información da garantía

Finder products are manufactured to high standards and are typically covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and duration, please refer to the documentation provided with your purchase or contact Finder directly.

7.2 Soporte técnico

For technical assistance, product inquiries, or support, please visit the official Finder website or contact their customer service department. Ensure you have your product model number (80.01.0.240.0000) available when seeking support.

Documentos relacionados - 80.01.0.240.0000

Preview Relé temporizador multifunción Finder 83.52: especificacións técnicas e manual
Especificacións técnicas detalladas, diagramas de conexión e instrucións de funcionamento para o relé temporizador multifunción Finder 83.52 de Finder. Inclúe información sobre o volumetage, corrente, funcións de temporización e instalación.
Preview Finder 83.02 Ex Multifunction Time Relay - Technical Datasheet
Detailed technical specifications, certifications, installation, and safety guidelines for the Finder 83.02 Ex multifunction time relay, suitable for hazardous locations (ATEX, IECEx, Hazloc).
Preview Temporizadores multifunción modulares Finder 83.11, 83.21, 83.41: datos técnicos
Explore as especificacións técnicas e as funcionalidades dos temporizadores multifunción modulares das series 83.11, 83.21 e 83.41 de Finder. Este documento detalla os diagramas de cableado, os rangos de tempo, as condicións de funcionamento e as pautas de instalación para estes relés temporizadores industriais.
Preview Finder 80.51 Multifunction Timer Relay - Technical Specifications and Operation
Comprehensive guide to the Finder 80.51 multifunction timer relay, detailing its technical specifications, electrical ratings, available functions, wiring diagrams, mounting instructions, and operational parameters.
Preview Finder Serie 86 ATEX - HazLoc Zeitmodule Technische Daten
Technische Spezifikationen und Daten für die Finder Serie 86 ATEX - HazLoc Zeitmodule. Dieses Dokument beschreibt die Funktionen, Zertifizierungen und technischen Eigenschaften dieser industriellen Zeitmodule für explosionsgefährdete Bereiche.
Preview Finder 83.02 Multifunction Time Relay - Technical Datasheet
Detailed technical specifications, functions, and operating instructions for the Finder 83.02 multifunction time relay, including connection diagrams and timing charts.