Fluke FLUKE-179/EDA2

Fluke 179/EDA2 Industrial Electronics Multimeter Combo Kit Instruction Manual

Comprehensive guide for the Fluke 179 True RMS Digital Multimeter and its accessories.

1. Produto rematadoview

The Fluke 179/EDA2 Industrial Electronics Multimeter Combo Kit is a full-featured digital multimeter (DMM) designed for advanced electronic troubleshooting. This kit includes the Fluke 179 True RMS Digital Multimeter with backlight, along with a comprehensive set of probes and accessories, all housed in a durable carrying case.

The Fluke 179 multimeter offers a wide range of measurement functions, adheres to the latest safety standards, and features a large, easy-to-view visualización.

Contido do kit:

  • Fluke 179 True RMS Digital Multimeter with backlight
  • Fluke TL224 Silicone Test Leads
  • Fluke TL910 Electronic Test Probes with replacement tips
  • Fluke AC280 Heavy Duty Hook Clips
  • Fluke 80BK-A Integrated Temperature Probe
  • Fluke C35 Durable Carrying Case
  • TPAK Magnetic Meter Hanger
Fluke 179/EDA2 Multimeter Combo Kit contents spread out
Figure 1: All components of the Fluke 179/EDA2 Industrial Electronics Multimeter Combo Kit, including the multimeter, various test leads, hook clips, temperature probe, magnetic hanger, and soft carrying case.

2. Configuración

2.1. Instalación da batería

The Fluke 179 Multimeter requires 4 AA alkaline batteries for operation. These are typically included with the kit. To install or replace batteries, refer to the instructions provided in the quick start guide or the full user manual for your specific model. Generally, this involves opening the battery compartment on the rear of the device, inserting the batteries with correct polarity, and securing the cover.

2.2. Conexión dos cables de proba

Ensure the multimeter is turned off before connecting or disconnecting test leads. Insert the black test lead into the COM (common) input jack and the red test lead into the appropriate input jack for your desired measurement (e.g., VΩmA for voltage, resistance, or current measurements).

Fronte view of the Fluke 179 True RMS Digital Multimeter
Figure 2: The Fluke 179 True RMS Digital Multimeter, showing the display, rotary dial, function buttons, and input jacks for test leads.

For specialized measurements, use the included accessories:

  • Fluke TL224 Silicone Test Leads: Standard leads for general measurements.
  • Fluke TL910 Electronic Test Probes with replacement tips: Ideal for precision work on small electronic components.
  • Fluke AC280 Heavy Duty Hook Clips: For secure connections to larger terminals or wires.
  • Fluke 80BK-A Integrated Temperature Probe: Connect to the appropriate input jacks for temperature measurements.
Fluke TL910 Electronic Test Probes with replacement tips
Figure 3: Fluke TL910 Electronic Test Probes, designed for precise measurements on electronic circuits, shown with various replacement tips.
Fluke TL224 Silicone Test Leads
Figure 4: Fluke TL224 Silicone Test Leads, featuring durable silicone insulation for flexibility and high-temperature resistance.
Fluke AC280 Heavy Duty Hook Clips
Figure 5: Fluke AC280 Heavy Duty Hook Clips, providing secure connections for hands-free testing on larger conductors.

3. Instrucións de funcionamento

The Fluke 179 Multimeter offers a variety of measurement functions. Always select the correct function and range before making a measurement to ensure accuracy and safety.

3.1. Medidas básicas

  • Voltage (CA/CC): Turn the rotary switch to V~ (AC) or V- (DC). Connect the test leads in parallel with the circuit or component to be measured.
  • Current (AC/DC): Turn the rotary switch to A~ (AC) or A- (DC) or mA/µA. Connect the test leads in series with the circuit. Ensure the correct input jack is used for the expected current level.
  • Resistencia (Ω): Turn the rotary switch to Ω. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance.
  • Continuidade: Turn the rotary switch to the continuity symbol (speaker icon). The meter will beep if a continuous path is detected.
  • Proba de diodo: Turn the rotary switch to the diode symbol. Connect the test leads across the diode to check its forward voltagcae.

3.2. Funcións avanzadas

  • Manual and Automatic Ranging: The multimeter can automatically select the appropriate measurement range. For specific applications, manual ranging can be selected.
  • Retención da pantalla: Prema o botón HOLD para conxelar a lectura actual na pantalla.
  • Retención automática: Automatically holds stable readings on the display.
  • Gravación mínima/máxima-media: Capture minimum, maximum, and average readings over a period, useful for monitoring fluctuating signals.
  • Frequency (Hz) and Capacitance (F) Measurements: Select the appropriate function on the rotary switch to measure frequency or capacitance.
  • Medición de temperatura: Connect the Fluke 80BK-A Integrated Temperature Probe to the multimeter and select the temperature function to measure temperature.
Technician using Fluke 179 Multimeter to test an electrical panel
Figure 6: A technician utilizing the Fluke 179 Multimeter to perform measurements on an electrical panel, demonstrating its application in industrial settings.
Technician using Fluke 179 Multimeter for troubleshooting electronics
Figure 7: An individual performing electronic troubleshooting with the Fluke 179 Multimeter, highlighting its precision for intricate tasks.

3.3. Demostracións en vídeo

Video 1: This video provides guidance on selecting the appropriate Fluke digital multimeter for various applications, showcasing the versatility of the Fluke 179.
Vídeo 2: Un breve resumoview of the Fluke 179 multimeter, demonstrating its key features and ease of use in a concise format.

4. Mantemento

4.1. Atención xeral

To ensure the longevity and accuracy of your Fluke 179 Multimeter, keep it clean and dry. Wipe the case with a damp cloth and mild detergent as needed. Do not use abrasives or solvents. Store the multimeter and its accessories in the provided Fluke C35 Durable Carrying Case when not in use to protect them from dust and physical damage.

4.2. Substitución da batería

When the low battery indicator appears on the display, replace the 4 AA alkaline batteries promptly. Always use fresh batteries of the specified type. Refer to the user manual for detailed instructions on safely opening the battery compartment and replacing the batteries.

5 Solución de problemas

If you encounter issues with your Fluke 179 Multimeter, consider the following basic troubleshooting steps:

  • Sen problemas de pantalla/alimentación: Check battery levels and ensure they are correctly installed. Replace batteries if necessary.
  • Lecturas inexactas: Verify that the correct function and range are selected for the measurement. Ensure test leads are properly connected and not damaged. Clean the test lead tips if they appear corroded.
  • Indicación "OL" (sobrecarga): This indicates that the measured value exceeds the selected range. Switch to a higher range or a different measurement function if applicable.
  • Continuity/Diode Test Not Working: Ensure the circuit is de-energized before performing these tests. Check for proper lead connection.

For more complex issues, consult the full Fluke 179 user manual or contact Fluke customer support.

6. Especificacións

CaracterísticaDetalle
Número de modeloFLUKE-179/EDA2
Dimensións do produto11.54 x 16 x 3.35 polgadas
Peso do elemento1.95 libras
Fonte de enerxíaPilas alcalinas
Pilas necesarias4 pilas AA (incluídas)
FabricanteFluke Corporation
EstiloELECTRONICS DMM AND DELUXE ACCESSORY COMBO KIT

7. Garantía e soporte

For warranty information and technical support, please refer to the documentation included with your Fluke 179/EDA2 kit or visit the official Fluke website. Fluke products are known for their reliability and often come with comprehensive support.

Podes visitar o Tenda Fluke en Amazon para obter máis detalles do produto e recursos de asistencia.

Documentos relacionados - FLUKE-179/EDA2

Preview Multímetro industrial de verdadeiro valor RMS Fluke serie 80 V: características e especificacións
Explore as características avanzadas e as especificacións detalladas do multímetro industrial de verdadeiro valor RMS Fluke serie 80 V, deseñado para a precisión e a produtividade en contornas industriais. Descubra as súas capacidades de resolución de problemas, funcións de medición e clasificacións de seguridade.
Preview FLUK-1550C-ACCY01 Accessory Kit - Advanced Test Equipment Corp.
Detailed list of accessories included in the FLUK-1550C-ACCY01 Accessory Kit from Advanced Test Equipment Corp., featuring part numbers, descriptions, quantities, and visual descriptions of each item.
Preview Multímetros dixitais do tamaño da palma da man Fluke 106/107: especificacións técnicas e características
Especificacións técnicas detalladas, aspectos destacados do produto e información xeral para os multímetros dixitais de tamaño palmar Fluke 106 e 107. Obtén información sobre as súas especificacións eléctricas, precisión, características e equipos incluídos.
Preview Manual do usuario do multímetro de verdadeiro valor rms Fluke 116
Manual do usuario do multímetro de verdadeiro valor rms Fluke 116, que abrangue as características, o funcionamento, a información de seguridade e as especificacións.
Preview Manual do usuario dos multímetros dixitais Fluke 15B+/17B+/18B+
Manual de usuario completo para os multímetros dixitais Fluke 15B+, 17B+ e 18B+, que abrangue as características, o funcionamento, a seguridade, o mantemento e as especificacións. Este documento ofrece instrucións detalladas para o uso dos multímetros en diversas medicións eléctricas.
Preview Multímetro dixital portátil Fluke 107 CAT III: especificacións técnicas
Especificacións técnicas detalladas, características e información xeral para o multímetro dixital portátil Fluke 107 CAT III. Inclúe medicións eléctricas, clasificacións de seguridade e detalles de pedido.