KERBL 29920

KERBL DigiScale 50 Digital Hanging Scales Instruction Manual

Modelo: 29920

Introdución

Thank you for choosing the KERBL DigiScale 50 Digital Hanging Scales. This manual provides essential information for the safe and efficient operation of your device. Please read these instructions carefully before use and retain them for future reference.

The KERBL DigiScale 50 is designed for fast and reliable weighing of items up to 50 kg. It features high accuracy, a pull-out measuring tape, and multiple display units.

Contido do paquete

  • KERBL DigiScale 50 Digital Hanging Scales (Model 29920)
  • Baterías (preinstaladas ou incluídas por separado)

Produto rematadoview

Familiarize yourself with the components of your DigiScale 50.

KERBL DigiScale 50 Digital Hanging Scales

Imaxe 1: Fronte view of the KERBL DigiScale 50, showing the digital display, ON/OFF, TARE, and SET buttons, and the hanging hook and handle.

  • Visualización: LCD screen for weight readings and unit indication.
  • Botón ON/OFF: Activa ou desactiva a báscula.
  • Botón TARE: Restablece a pantalla a cero, útil para pesar elementos nun recipiente.
  • Botón SET: Used to change weighing units (kg/lb/oz) and temperature unit (°C).
  • Gancho para colgar: For attaching items to be weighed.
  • Manexar: For holding the scale during weighing.
  • Cinta métrica: Pull-out tape for length measurements (100 cm).

Configuración

1. Instalación da batería

The DigiScale 50 is supplied with batteries. If replacement is needed:

  1. Localice o compartimento da batería na parte traseira da báscula.
  2. Abra a tapa do compartimento.
  3. Insira pilas novas, asegurándose da polaridade correcta (+/-).
  4. Pecha a tapa do compartimento da batería de forma segura.

2. Acendido inicial

Preme o ON/OFF button to turn on the scale. The display will show "8888" and then "0.00" or "0.0" with the current unit.

Instrucións de funcionamento

1. Weighing an Item

  1. Ensure the scale is powered on and displaying "0.00".
  2. Hold the scale by its handle.
  3. Carefully attach the item to be weighed to the hanging hook.
  4. Wait for the display to stabilize. The weight will be shown.
  5. The scale features a data hold function, which will lock the stable weight reading on the display.

2. Changing Weighing Units

Coa báscula acendida, prema o botón SET button repeatedly to cycle through the available units: kg (kilograms), lb (pounds), oz (ounces), and °C (Celsius for temperature display).

3. Función de tara

The Tare function allows you to weigh items in a container by subtracting the container's weight.

  1. Hang the empty container on the hook.
  2. Agarde a que a pantalla se estabilice.
  3. Preme o TAREAR botón. A pantalla restablecerase a "0.00".
  4. Place the item to be weighed into the container. The display will show the net weight of the item.

4. Using the Measuring Tape

Using the integrated measuring tape on the KERBL DigiScale 50

Imaxe 2: A hand pulling out the integrated measuring tape from the side of the KERBL DigiScale 50, demonstrating its use for length measurement.

The DigiScale 50 includes a retractable measuring tape for convenience. Gently pull the tape from its housing to extend it. After use, guide it back into the housing.

5. Apagado automático

To conserve battery life, the scale will automatically turn off after a period of inactivity.

Mantemento

  • Limpar a báscula cun suave, damp pano. Non use produtos de limpeza abrasivos nin somerxa o dispositivo en auga.
  • Garda a báscula nun lugar seco, lonxe de temperaturas extremas e da luz solar directa.
  • Se non se vai usar a báscula durante un período prolongado, retire as pilas para evitar fugas.

Resolución de problemas

ProblemaCausa posibleSolución
A escala non se acende.Baterías gastadas ou instaladas incorrectamente.Substitúa as pilas ou comprobe a polaridade.
Lecturas inexactas.Scale not stable, overloaded, or on an uneven surface.Ensure scale is held steadily. Do not exceed 50 kg capacity. Use on a stable surface.
A pantalla mostra "Err" ou "O-Ld".Sobrecarga.Remove the item immediately. Do not exceed the maximum capacity of 50 kg.

Especificacións

  • Modelo: 29920
  • Marca: KERBL
  • Capacidade máxima: 50 kg
  • Tipo de visualización: LCD
  • Unidades: kg, lb, oz, °C
  • Características especiais: Lightweight, Portable, Smart, Data Hold Function, Automatic Shutdown, Integrated 100 cm Measuring Tape.
  • Fonte de enerxía: Pilas (incluídas)
  • Cor: Negro
  • Dimensións (paquete): 5.67 x 3.19 x 1.42 polgadas

Garantía e Soporte

For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official KERBL websitio. Garda o comprobante de compra para reclamacións de garantía.

Documentos relacionados - 29920

Preview Báscula para animais AniScale n.º 291322 - Instrucións de funcionamento
Instrucións de funcionamento para a báscula para animais KERBL AniScale n.º 291322, que detallan a configuración, o funcionamento, as precaucións de seguridade e as especificacións técnicas para pesar animais de ata 1500 kg.
Preview PS 1000/PS 2000/PS 3000 Quick User Guide
This guide provides essential information for the installation, operation, and maintenance of the Kerbl PS 1000, PS 2000, and PS 3000 scales. It covers safety precautions, electrical installation, routine maintenance, cleaning, and operational features such as zeroing, taring, unit selection, hold mode, and printing.
Preview KERBL Weighing Loadbar Set with Display Operating Instructions
Comprehensive operating instructions for the KERBL Weighing Loadbar Set with Display (models #291365, #291366), covering setup, functions, maintenance, and troubleshooting. Available in multiple languages.
Preview KERBL EasyProtect Automatische Hühnertür Bedienungsanleitung
Die KERBL EasyProtect Automatische Hühnertür automatisiert das Öffnen und Schließen der Stalltür für Geflügelhalter. Sie funktioniert über Zeitsteuerung oder Lichtsensor und erhöht die Sicherheit und den Komfort im Hühnerstall. Dieses Handbuch bietet detaillierte Anleitungen zur Installation, Bedienung und Wartung.
Preview PS1000/PS2000/PS3000 Scale Calibration Guide
This guide provides instructions for calibrating the Kerbl PS1000, PS2000, and PS3000 scales, including parameter settings and calibration procedures.
Preview Kerbl C10 Zirkulationspumpe: Bedienungsanleitung & Technische Daten
Umfassende Bedienungsanleitung für die Kerbl C10 Zirkulationspumpe. Erfahren Sie mehr über Montage, Betrieb, Wartung und technische Spezifikationen für landwirtschaftliche Anwendungen.