Introdución
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump, Model 4117301. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.
Información de seguridade
Always adhere to local regulations and safety standards during installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Asegúrese de desconectar a alimentación eléctrica antes de calquera traballo de instalación, mantemento ou reparación.
- A instalación e as conexións eléctricas só deben ser realizadas por persoal cualificado.
- Do not operate the pump if it is damaged or if the electrical connections are exposed.
- This pump is designed for residential closed-loop water heating systems. It is not approved for domestic hot water aplicacións.
- Protexa a bomba de temperaturas de conxelación.
Produto rematadoview
The Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump is designed for efficient circulation in heating systems. Key features include:
- Alta eficiencia: Optimized for energy savings in circulating applications.
- Rango de temperatura: Operates effectively within a temperature range of 14°F to 230°F (-10°C to 110°C).
- Rendemento: Provides a maximum head of 16 feet with a maximum flow rate of 16 GPM.
- Instalación flexible: Features a flange that can be rotated 90 degrees for versatile mounting.
- Conexión sinxela: Equipped with quick-connect electrical terminals for simplified wiring.

Figure 1: Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump. This image shows the pump from a slightly elevated side angle, highlighting its compact design, the green pump housing, and the grey and black control unit with a red dial and energy efficiency indicator.
Instalación e Configuración
Follow these steps for proper installation of the circulating pump:
- Montaxe: Securely mount the pump in the desired position within the closed-loop heating system. The flange can be rotated 90 degrees to accommodate various pipe orientations.
- Tubería: Connect the pump to the heating system piping. Ensure all connections are watertight and free of leaks.
- Conexión eléctrica:
- Asegúrese de que a fonte de alimentación principal estea APAGADA.
- Connect the 115-Volt power supply to the quick-connect electrical terminals. Refer to the wiring diagram provided with the pump for specific connections.
- Asegúrate de que todas as conexións eléctricas estean seguras e debidamente illadas.
- Recheo do sistema: Fill the heating system with water and bleed any air from the system. Proper air removal is crucial for efficient pump operation.
- Verificación inicial: Before powering on, double-check all connections and ensure the system is properly filled and free of air.
Instrucións de funcionamento
Once installed and connected, operate the pump as follows:
- Encendido: Restore power to the pump. The pump will typically start in an automatic mode.
- Selección de modo: Use the control dial on the pump's interface to select the desired operating mode. The Stratos ECO series often features automatic adjustment to system requirements, but manual settings for constant pressure or proportional pressure may be available. Consult the markings on the control unit for specific options.
- Seguimento: Observe the pump's operation and the system's performance. The integrated display or indicators will show the current operating status and energy consumption.
Mantemento
Regular maintenance ensures the longevity and optimal performance of your Wilo pump.
- Inspección anual: Annually inspect the pump for any signs of wear, leaks, or unusual noises.
- Calidade da auga do sistema: Ensure the heating system water quality is maintained according to manufacturer recommendations to prevent corrosion and scale buildup.
- Limpeza: Keep the exterior of the pump clean and free from dust and debris. Do not use abrasive cleaners.
- Sangrado de aire: Periodically check and bleed air from the heating system to prevent cavitation and ensure smooth operation.
Resolución de problemas
Se tes problemas coa bomba, consulta os seguintes problemas e solucións comúns:
| Problema | Causa posible | Solución |
|---|---|---|
| A bomba non funciona | No power supply; Motor jammed; Electrical fault | Check power connection and circuit breaker; Consult a qualified technician for motor or electrical issues. |
| Bomba facendo ruído inusual | Air in system; Cavitation; Bearing wear | Bleed air from the system; Ensure adequate water pressure; Contact service if noise persists. |
| Fluxo/presión insuficiente | Air in system; Incorrect operating mode; Clogged impeller | Bleed air; Adjust operating mode; Inspect and clean impeller (power off first). |
If the problem persists after attempting these solutions, contact Wilo customer support or a certified service technician.
Especificacións
| Atributo | Detalle |
|---|---|
| Número de modelo | 4117301 |
| Marca | Wilo |
| Cabeza máxima | 16 pés |
| Caudal máximo | 16 GPM |
| Voltage | 115 voltios |
| Rango de temperatura | 14 °F a 230 °F (-10 °C a 110 °C) |
| Aplicación | Residential closed-loop water heating systems (Not for domestic hot water) |
| Peso do elemento | 3 kg 580 g |
| Dimensións do paquete | 23.37 x 22.61 x 22.35 cm |
Garantía e Soporte
The Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump comes with a 3 ano de garantía. For warranty claims, technical support, or service inquiries, please contact Wilo customer service. Ensure you have your model number (4117301) and purchase details available when contacting support.
For the most up-to-date contact information, please visit the official Wilo websitio web ou consulte a documentación incluída co produto.