1. Introdución
The Altronix ACM8 Access Power Controller is designed to manage power distribution for access control systems. This unit features eight individually fused trigger outputs, providing reliable power and protection for various access control devices. It is suitable for a range of applications requiring controlled power distribution.
2. Produto rematadoview
The ACM8 is a versatile power distribution board, ideal for integrating with access control panels. It provides individually fused outputs, ensuring protection for connected devices. The board is constructed from durable phenolic or fiberglass material and is UL Recognized, meeting UL294 standards for access control system units.

Figura 1: De arriba abaixo view of the Altronix ACM8 Access Power Controller board, showing the eight fused outputs, relays, and terminal blocks.

Figura 2: En ángulo view of the Altronix ACM8 Access Power Controller, highlighting the compact design and component layout.
3. Características
- Eight individually fused outputs for device protection.
- Vol. De entradatage: 12 to 24 Volt AC or DC.
- Vol. De saídatage: 12 to 24 Volt AC or DC.
- UL Recognized and UL294 compliant for access control applications.
- Constructed from durable Phenolic or Fiberglass material.
- Compact dimensions for easy integration.
4. Especificacións
| Especificación | Detalle |
|---|---|
| Número de modelo | ACM8 |
| Dimensións do produto (L x W x H) | 8 x 4.5 x 1.25 polgadas |
| Vol. De entradatage | 12 to 24 Volt AC or DC |
| Vol. De saídatage | 12 to 24 Volt AC or DC |
| Número de Saídas | 8 (Fused) |
| Material | Phenolic or Fiberglass |
| Estándares | UL RECOGNIZED, UL294 |
| Peso do elemento | 11.2 onzas |
| Fabricante | ALTRONIX |
5. Configuración
- Montaxe da unidade: Securely mount the ACM8 board in a suitable enclosure or panel using appropriate hardware. Ensure adequate ventilation if enclosed.
- Conexión de alimentación: Connect the main power source (12-24V AC or DC) to the designated input terminals. Observe correct polarity when using a DC input. Refer to the board markings for positive (+) and negative (-) terminals.
- Conexións de saída: Connect your access control devices (e.g., locks, readers) to the individually fused output terminals. Each output provides power when triggered. Ensure proper wiring for each connected device according to its specifications.
- Entrada de activación: Connect the trigger input from your access control panel or other control device to the ACM8's trigger terminals. This signal will activate the corresponding output.
- Conexión a terra: Ensure the unit is properly grounded according to local electrical codes and safety standards.
6. Instrucións de funcionamento
- Encendido: Once all connections are secure and verified, apply power to the ACM8 unit.
- Indicadores LED: Each output has an associated LED indicator. When an output is active and power is flowing correctly through its fuse, the corresponding LED will illuminate.
- Funcionalidade do disparador: When a trigger signal is received at the input, the ACM8 will activate the designated output, providing power to the connected access control device.
- Fuse Monitoring: The LED indicators also serve as a visual check for fuse integrity. If an LED is off when the output should be active, it indicates a potential blown fuse or a wiring issue to the connected device.
7. Mantemento
- Inspección periódica: Inspeccione periodicamente todas as conexións do cableado para garantir que estean seguras e libres de corrosión ou danos.
- Substitución de fusibles: If an output fuse blows, always replace it with a fuse of the same type and rating (e.g., 250V, 2A). Using an incorrect fuse can damage the unit or connected devices.
- Limpeza: Keep the unit free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
- Condicións ambientais: Ensure the operating environment remains within specified temperature and humidity ranges to prevent malfunction.
8 Solución de problemas
- No Power to Any Outputs:
- Verify that the main input power supply is active and correctly connected to the ACM8.
- Check the main fuse (if applicable to your power supply) and ensure it is intact.
- Individual Output Failure (LED off when active):
- Check the specific output fuse for the affected channel. Replace if blown.
- Verify the wiring to the connected device for shorts or disconnections.
- Ensure the trigger signal for that specific output is being received correctly.
- Funcionamento intermitente:
- Inspect all terminal connections for looseness.
- Consulta o voltage fluctuations from the input power supply.
9. Garantía e soporte
For detailed warranty information, technical assistance, or to inquire about service, please contact Altronix customer service directly or visit the official Altronix websitio. Conserve o recibo de compra para reclamacións de garantía.