Testboy TV 430N

Manual do usuario do comprobador de illamento dixital Testboy TV 430N

1. Introdución

This manual provides detailed instructions for the safe and effective use of the Testboy TV 430N Digital Insulation Tester. This device is designed for measuring insulation resistance, performing continuity tests, and measuring AC voltage. Please read this manual thoroughly before operating the device.

2. Información de seguridade

Always adhere to the following safety precautions to prevent electric shock, injury, or damage to the device:

  • Non empregue o dispositivo se parece estar danado ou funciona de forma anormal.
  • Ensure test leads are in good condition, free from cracks or damaged insulation.
  • Do not exceed the maximum input ratings for any function. The device is rated CAT II 600V.
  • Always disconnect power to the circuit before making insulation resistance measurements.
  • Be aware of residual voltage in the circuit after testing. The device automatically discharges the circuit after insulation tests.
  • Substitúa as pilas canto antes apareza o indicador de pila baixa.
  • Non opere o dispositivo en ambientes húmidos ou atmosferas explosivas.

3. Produto rematadoview

The Testboy TV 430N features a clear digital display and intuitive controls for various measurement functions.

Testboy TV 430N Digital Insulation Tester front view con pantalla e controis

Figure 1: Testboy TV 430N Digital Insulation Tester
This image displays the front panel of the Testboy TV 430N. Key components include a large digital display for readings, a central rotary function dial for selecting measurement modes (OFF, 250V, 500V, 1000V insulation resistance, continuity/resistance, AC voltage), and control buttons such as 'TEST' (red, circular), 'LOCK', 'HOLD', and a backlight button. Input terminals for test leads are located at the top of the device, labeled G, ACV Ω, and L A, E.

Compoñentes clave:

  • Pantalla dixital: Shows measurement values, units (MΩ, V), and status indicators (e.g., 'H' for Hold, low battery).
  • Dial de función: Used to select the desired measurement mode: OFF, Insulation Resistance (250V, 500V, 1000V), Continuity/Resistance (Ω), and AC Voltage (ACV).
  • Botón TEST: Initiates an insulation resistance test.
  • Botón de bloqueo: Engages continuous insulation resistance testing.
  • Botón HOLD: Conxela a lectura actual da pantalla.
  • Botón de retroiluminación: Activates the display backlight for improved visibility in low light conditions.
  • Terminais de entrada: Connect test leads for measurements. Labeled G, ACV Ω, L A, E.

4. Configuración

4.1 Instalación da batería

  1. Ensure the device is switched OFF.
  2. Localiza o compartimento da batería na parte traseira do dispositivo.
  3. Abra a tapa do compartimento da batería.
  4. Insert six (6) 1.5V AA LR06 batteries, observing correct polarity.
  5. Pecha a tapa do compartimento da batería de forma segura.

Agora o dispositivo está listo para funcionar.

5. Instrucións de funcionamento

5.1 Medición da resistencia de illamento

This function measures the resistance of insulation in electrical systems and components.

  1. Asegúrese de que o circuíto baixo proba estea desenergizado e descargado de forma segura.
  2. Connect the test leads to the appropriate terminals on the device and to the circuit under test.
  3. Turn the Function Dial to the desired insulation test voltage (250 V, 500 V ou 1000 V).
  4. Manteña premido o PROBA button. The display will show the insulation resistance value in MΩ.
  5. For continuous testing, press the BLOQUEO button after pressing PROBA. Preme BLOQUEO de novo para liberar.
  6. Soltar o PROBA button to stop the measurement. The device will automatically discharge the circuit.

5.2 Probas de continuidade

This function checks for a continuous electrical path in a circuit.

  1. Asegúrese de que o circuíto baixo proba estea desenergizado.
  2. Connect the test leads to the appropriate terminals on the device and to the circuit under test.
  3. Turn the Function Dial to the Continuity/Resistance (Ω) position.
  4. If continuity is detected (low resistance), an audible tone will sound, and the resistance value will be displayed.

5.3 AC Voltage Medición

This function measures alternating current voltage.

  1. Connect the test leads to the appropriate terminals on the device and to the voltage fonte.
  2. Turn the Function Dial to the AC Voltage (ACV) position.
  3. A pantalla mostrará o AC voltage value in Volts.

6. Mantemento

6.1 Substitución da batería

Substitúa as baterías cando apareza o indicador de batería baixa na pantalla. Consulte a Sección 4.1 para obter instrucións de instalación da batería.

6.2 Limpeza

Limpa o dispositivo cun anuncioamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage or use.

7 Solución de problemas

  • Sen visualización: Comprobe a instalación e a carga das baterías. Substitúa as baterías se é necesario.
  • Lecturas incorrectas: Ensure test leads are properly connected and not damaged. Verify the correct function is selected on the dial.
  • No Continuity Tone: Check if the circuit is truly continuous and if the resistance is within the device's detection range.
  • O dispositivo non responde: Turn the device OFF, remove batteries, wait a few minutes, then reinsert batteries and turn ON. If the issue persists, contact support.

8. Especificacións

ParámetroValor
Test Voltages250 V DC, 500 V DC, 1000 V DC
Rango de resistencia de illamento2 MΩ to 2000 MΩ
Probador de continuidadeIntegrado
Voltímetro CA.Integrated (up to 600V AC MAX)
Fonte de enerxía6 x 1.5V AA LR06 Batteries (included)
Dimensións do produto (L x W x H)18.8 x 11 x 6.2 cm
Peso do elemento0.49 kg (485 g)
Valoración de seguridadeCAT II 600 V

9. Garantía e soporte

The Testboy TV 430N Digital Insulation Tester comes with a 5 anos de garantía do fabricante desde a data de compra. Esta garantía cobre defectos de materiais e fabricación en condicións de uso normal.

For technical support, warranty claims, or service inquiries, please contact Testboy customer service through their official website or authorized distributors. Please have your product model number and purchase information available when contacting support.

Documentos relacionados - TV 430N

Preview Testboy® 15: Bedienungsanleitung und Sicherheitshinweise
Erfahren Sie mehr über das Testboy® 15 Magnetfeld-Messgerät. Diese Anleitung enthält wichtige Informationen zur Bedienung, Sicherheitshinweisen und technischen Daten des Geräts von Testboy GmbH.
Preview Testboy TV 510 PV Module Tester - User Manual and Specifications
Comprehensive user manual and technical specifications for the Testboy TV 510 PV module tester, covering safety instructions, operation, and disposal.
Preview Testboy 113: Bedienungsanleitung, Sicherheitshinweise und technische Daten
Die offizielle Bedienungsanleitung für das Testboy 113 Messgerät. Erfahren Sie mehr über berührungslose Spannungsprüfung, Sicherheitshinweise, technische Daten und die fachgerechte Anwendung dieses electricischen Prüfgeräts von Testboy GmbH.
Preview Multímetro dixital Testboy TB 313 Bedienungsanleitung
Umfassende Bedienungsanleitung für das digitale Multimeter Testboy TB 313. Enthält Informationen zu Sicherheit, Bedienung, Messfunktionen, Wartung und technischen Daten. Ideal para Handwerk, Industrie e Hobby-Elektroniker.
Preview Testboy 40 Simple Two-Pole Voltage Tester - Specifications and Features
Detailed information on the Testboy 40 Simple, a robust and user-friendly two-pole voltage tester with LED display, 12-690V AC/DC range, continuity testing up to 500 kΩ, and single-pole phase detection. Features CAT IV 300V / CAT III 600V rating and IP54 protection.
Preview Testboy TB 27 Analog Bedienungsanleitung: Kabel- und Durchgangsprüfer
Entdecken Sie die Funktionen und Anwendung des Testboy TB 27 Analog Cabel- und Durchgangsprüfers. Diese Anleitung bietet detaillierte Informationen zu Bedienung, Sicherheit und technischen Spezifikationen für Elektriker und Techniker.