Introdución

This manual provides detailed instructions for converting a Pentair MasterTemp 250 pool heater from Liquid Propane (LP) to Natural Gas (NG) operation using the Pentair 460742 Conversion Kit. It is essential to read and understand all instructions thoroughly before beginning the conversion process to ensure safe and correct installation.

Información de seguridade

AVISO: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. This conversion kit must be installed by a qualified service technician in accordance with all local codes and ordinances.

Contido do paquete

Verify that all components are present in your Pentair 460742 Conversion Kit:

Pentair 460742 Propane to Natural Gas Conversion Kit components

Image showing the components typically included in the Pentair 460742 Propane to Natural Gas Conversion Kit, which facilitates the conversion of a MasterTemp 250 heater from LP to Natural Gas.

Configuración e instalación

This section outlines the general steps for converting your Pentair MasterTemp 250 heater. Refer to the specific heater model's service manual for detailed diagrams and safety procedures, as these instructions are supplementary.

  1. Preparación:
    • Turn off the main gas supply to the heater at the source.
    • Disconnect electrical power to the heater at the circuit breaker.
    • Allow the heater to cool completely if it has been in operation.
  2. Accessing the Burner Tray:
    • Remove the heater's top and front panels to gain access to the burner assembly.
    • Carefully disconnect any wiring or sensors that obstruct access to the burner tray, noting their original positions.
  3. Replacing the Orifice:
    • Locate the existing LP gas orifice on the manifold.
    • Using appropriate tools, carefully remove the LP orifice.
    • Install the new Natural Gas orifice from the conversion kit. Ensure it is securely tightened to prevent leaks.
  4. Adjusting the Gas Valve (if applicable):
    • Some gas valves require adjustment for Natural Gas pressure. Consult the heater's service manual for specific instructions on adjusting the gas valve regulator.
    • Typically, this involves removing a cap and turning an adjustment screw to set the correct manifold pressure for Natural Gas.
  5. Remontaxe:
    • Reinstall any removed wiring or sensors, ensuring all connections are secure.
    • Replace the front and top panels of the heater, ensuring they are properly seated and secured.
    • Affix the new "Natural Gas" conversion label from the kit in a prominent location on the heater, covering the old "Liquid Propane" label. This is crucial for safety and future servicing.
  6. Proba de fugas:
    • Turn on the main gas supply to the heater.
    • Apply a non-corrosive leak detection solution (e.g., soapy water) to all gas connections made or disturbed during the conversion.
    • Look for bubbles, which indicate a leak. If a leak is detected, immediately shut off the gas supply and tighten connections until no leaks are present. Repeat the test.
  7. Comprobacións finais:
    • Restore electrical power to the heater.
    • Initiate a test fire of the heater to ensure proper operation and flame characteristics.
    • Verify that the heater is operating efficiently and safely on Natural Gas.

Operating After Conversion

Once the conversion is complete and verified by a qualified technician, operate your Pentair MasterTemp 250 heater according to its original operating manual, now configured for Natural Gas. Ensure the gas type setting on the heater's control panel, if adjustable, is correctly set to "Natural Gas."

Mantemento

Regular maintenance of your converted heater is crucial for its longevity and safe operation. This includes:

Resolución de problemas

If you encounter issues after converting your heater, consider the following:

For persistent issues, consult the Pentair MasterTemp 250 heater's service manual or contact a qualified service professional.

Especificacións

Garantía e Soporte

For warranty information regarding the Pentair 460742 Conversion Kit, please refer to the documentation included with your original Pentair MasterTemp 250 heater or visit the official Pentair website. For technical support, contact Pentair customer service or a certified Pentair service provider.

Oficial de Pentair Websitio: www.pentair.com

Documentos relacionados - 460742

Preview Guía de instalación e usuario do quentador de alto rendemento Pentair MasterTemp 125
Guía oficial de instalación e usuario do quentador de piscina e spa de alto rendemento Pentair MasterTemp 125. Inclúe detalles de seguridade, instalación, funcionamento, resolución de problemas e mantemento para modelos de gas natural e propano.
Preview Instrucións de instalación do kit de conversión de gas natural a propano para quentador de piscina Pentair ETi 250
Este documento proporciona instrucións de instalación detalladas para converter o quentador de piscina Pentair ETi 250 de gas natural a propano (GLP) usando o kit P/N 476370. Inclúe avisos de seguridade esenciais, unha lista de ferramentas e pezas necesarias, procedementos de conversión paso a paso e pasos de verificación da presión de subministración de gas. Asegúrese de cumprir todos os códigos e regulamentos aplicables.
Preview Guía de instalación e usuario do quentador de piscina e spa Pentair Mastertemp
Guía de instalación e usuario do quentador de piscina e spa Pentair Mastertemp, incluíndo avisos de seguridade, información sobre o modelo e procedementos en caso de fugas de gas.
Preview Pentair MasterTemp Pool and Spa Heater Installation and User's Guide
Comprehensive guide for the installation, operation, and maintenance of the Pentair MasterTemp Pool and Spa Heater. Covers safety, specifications, installation, operation, troubleshooting, and maintenance.
Preview Pentair Automatic By-Pass Valve Kit (P/N 462048) Installation Instructions
Comprehensive installation guide for the Pentair Automatic By-Pass Valve Kit (P/N 462048), designed for MasterTemp and Max-E-Therm pool and spa heaters. Includes essential safety warnings, an overview of the system's benefits, detailed setup procedures for plumbing and actuator mounting, and step-by-step instructions for configuring home and end positions for optimal pool hydraulics.
Preview Pentair ETi 250 Condensate Neutralizer Kit Installation Guide
Installation and safety instructions for the Pentair ETi 250 High Efficiency Heater Condensate Neutralizer Kit (P/N 476375), including operational guidelines and maintenance recommendations.