Sicce 925607

Sicce Ultrazero Flat Sucking Pump Instruction Manual

Modelo: 925607

1. Produto rematadoview

The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.

Características principais:

  • Capable of pumping water down to 2 mm residual level.
  • Fully submersible design.
  • Handles dirt particles up to 3 mm in size.
  • Equipado cun cable de alimentación de 10 metros.
  • Features a practical carry handle for easy transport.
Sicce Ultrazero Flat Sucking Pump

Figura 1: Máisview of the Sicce Ultrazero Flat Sucking Pump.

2. Información de seguridade

Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance.
  • Asegúrese de que a fonte de alimentación voltage matches the pump's specifications (230 V/50 Hz).
  • Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
  • Do not use the pump to handle flammable or explosive liquids.
  • Manteña os nenos e as persoas non autorizadas lonxe da zona de funcionamento.
  • Ensure the pump is fully submerged during operation to prevent overheating.
  • Avoid running the pump dry for extended periods.
  • This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.

3. Configuración e instalación

Follow these steps to properly set up your Ultrazero pump:

  1. Desembalar a bomba: Retire con coidado a bomba e todos os accesorios da embalaxe. Inspeccione se hai algún dano.
  2. Conecte a mangueira de descarga:

    The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

    Pump outlet and handle

    Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.

  3. Colocación da bomba: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
  4. Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
  5. Conexión de alimentación: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.
Base da bomba

Figure 3: The flat base of the pump designed for low residual water levels.

4. Instrucións de funcionamento

The Ultrazero pump is designed for simple operation:

  1. Submerxe a bomba: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
  2. Comezar a bombear: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
  3. Monitor de nivel de auga: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
  4. Deixar de bombear: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.
Pump draining a small pool

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Pump draining a flooded floor

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Pump showing 2mm residual water level

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.

5. Mantemento

Un mantemento regular garante a lonxevidade e o rendemento óptimo da súa bomba.

  • Limpeza: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
  • Inspeccionar por residuos: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
  • Inspección de cables: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
  • Almacenamento: When not in use, store the pump in a clean, dry place, protected from frost.
Pump used for garden watering

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.

6 Solución de problemas

If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:

ProblemaCausa posibleSolución
A bomba non arranca.Sen fonte de alimentación.
Cable de alimentación danado.
Protección contra sobrecarga do motor activada.
Comprobe a conexión e a toma de corrente.
Inspect cable for damage; replace if necessary (by qualified personnel).
Disconnect power, allow motor to cool, then reconnect.
A bomba funciona pero non sae auga.Intake blocked.
Discharge hose kinked or blocked.
Airlock in pump.
Disconnect power, clear intake.
Check and clear discharge hose.
Briefly lift and lower the pump while submerged to release trapped air.
Rendemento de bombeo reducido.Partial blockage.
Impeller worn.
Disconnect power, clean pump intake and impeller area.
Contact customer support for service.
A bomba para inesperadamente.Overheating due to low water level or blockage.
Fallo eléctrico.
Disconnect power, check water level and clear blockages. Allow to cool.
Se o problema persiste, póñase en contacto co servizo de atención ao cliente.

If the problem persists after attempting these solutions, please contact Sicce customer support.

7. Especificacións técnicas

Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:

EspecificaciónValor
MarcaSicce
Número de modelo925607
Max. Delivery Rate (Flow Rate)3000 l/h
Máx. Altura de entrega3.1 m
Power Consumption (P1)80 W
Vol. Operativotage220-240V/50Hz
Conductor Length (Power Cable)10 m (three-core, indoor and outdoor use)
Conexión de presión26.44 mm (3/4") AG
Diámetro da conexión da mangueira20 mm (3/4")
Max. Solids Size3 mm
Nivel de auga residualDown to 2-3 mm
Dimensións do produto (aprox.)140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3"
Peso do elemento2.6 kg (5.72 lb)
Interruptor flotanteNon
Protección contra sobrecargaNo (Internal thermal protection may exist, but no external reset)
OrixeFeito en Italia
Technical drawing with pump dimensions

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.

8. Garantía e soporte

For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.

Fabricante: Ebara

Marca: Sicce

For further assistance, visit the official Sicce websitio web ou póñase en contacto co seu distribuidor local.