1. Introdución
This manual provides essential information for the safe and effective installation, operation, and maintenance of the AUTONICS AT11DN-24-240 Multi-Function Timer. This device is designed for precise timing control in various industrial and commercial applications, offering a wide timing range from 0.05 seconds to 100 hours and operating on 100VAC-240VAC power.
2. Precaucións de seguridade
Read these safety precautions carefully before using the product to ensure proper and safe operation. Failure to follow these instructions may result in electric shock, fire, or product damage.
- Seguridade eléctrica: Ensure all wiring is performed by qualified personnel in accordance with local and national electrical codes. Disconnect power before installation, inspection, or maintenance.
- Fonte de alimentación: Verifique que a fonte de alimentación voltage coincide co volume especificado do produtotage range (100VAC-240VAC). Incorrect voltage pode causar danos.
- Entorno de instalación: Install the timer in an environment free from excessive vibration, dust, moisture, corrosive gases, or direct sunlight. Ensure adequate ventilation.
- Conexións de terminal: Securely fasten all terminal connections to prevent loose contacts, which can lead to overheating or malfunction.
- Capacidade de carga: Do not exceed the specified contact rating (5A resistive load). Overloading can damage the internal relay.
3. Produto rematadoview
The AUTONICS AT11DN-24-240 is a compact multi-function timer featuring a clear rotary dial for time setting and various indicators for operational status.

Figure 1: Front panel of the AUTONICS AT11DN-24-240 Multi-Function Timer.
This image displays the front panel of the AUTONICS AT11DN-24-240 Multi-Function Timer. Visible elements include the central rotary dial for time setting, marked with a scale from 0 to 10. Above the dial, there are 'POWER' and 'RUN' indicator lights. To the right, an 'OUT' indicator and a 'MODE' selector switch are present. The brand name 'Autonics' is printed at the bottom right of the panel.
3.1. Compoñentes do panel frontal
- Time Setting Dial: Rotary dial for setting the desired time value within the selected range.
- Indicador POWER: Illuminates when power is supplied to the timer.
- Indicador RUN: Illuminates during the timing operation.
- Indicador OUT: Illuminates when the output relay is activated.
- MODE Selector: Switch to select the desired operating mode (e.g., ON-delay, Interval).
4. Configuración
4.1. Montaxe
The AT11DN-24-240 timer is designed for panel mounting. Ensure sufficient space for wiring and ventilation. Secure the timer using the provided mounting hardware.
4.2. Cableado
Refer to the wiring diagram printed on the side of the timer or in the detailed product datasheet for specific terminal connections. Common connections include:
- Fonte de alimentación (100-240 V CA): Conecte a fonte de alimentación principal aos terminais designados.
- Contactos de saída: Connect the load to the normally open (NO) and common (COM) terminals of the output relay. Ensure the load current does not exceed 5A resistive.
- Control Input (if applicable): Some modes may utilize external control inputs (e.g., START, RESET). Connect these as per the specific mode's requirements.
Warning: Ensure power is disconnected before performing any wiring.
4.3. Configuración inicial
- Selección de intervalo de tempo: The timer supports various time ranges (e.g., seconds, minutes, hours). Select the appropriate range using the internal DIP switches or external selector, if present (refer to the detailed product datasheet for specific model configuration).
- Selección do modo de funcionamento: Use the 'MODE' selector switch on the front panel to choose the desired timing function (e.g., ON-delay, OFF-delay, Interval, Flicker).
5. Instrucións de funcionamento
5.1. Axustar a hora
Rotate the central time setting dial to the desired time value. The dial is typically marked with a scale from 0 to 10, representing a percentage of the selected time range. For example, if the range is 10 minutes, setting the dial to '5' would correspond to 5 minutes.
5.2. Acendido
Once wiring and settings are complete, apply power to the timer. The 'POWER' indicator will illuminate.
5.3. Timing Operation
Depending on the selected mode:
- For ON-delay mode, timing begins immediately upon power application or trigger. The 'RUN' indicator will illuminate.
- Upon completion of the set time, the output relay will activate, and the 'OUT' indicator will illuminate.
- For other modes, refer to the specific timing chart in the detailed product datasheet.
6. Mantemento
The AUTONICS AT11DN-24-240 timer is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure optimal performance.
- Limpeza: Gently wipe the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspección: Periodically inspect wiring connections for tightness and signs of wear or damage. Check for any unusual sounds or odors during operation.
- Almacenamento: If storing the timer, keep it in a dry, dust-free environment within the specified temperature and humidity ranges.
7 Solución de problemas
If the timer does not operate as expected, consult the following table before contacting support.
| Problema | Causa posible | Solución |
|---|---|---|
| Timer does not power on (POWER indicator off) | No power supply; Incorrect wiring; Blown fuse (external) | Check power source; Verify wiring connections; Inspect external fuse. |
| Timing does not start (RUN indicator off) | Incorrect mode selection; No trigger signal (if applicable); Faulty unit | Verify operating mode; Check trigger input; Contact support if unit is faulty. |
| Output does not activate (OUT indicator off) | Timing not complete; Incorrect load wiring; Overloaded output | Wait for timing cycle to complete; Check load connections; Ensure load current is within 5A resistive. |
| Temporalización inexacta | Incorrect time setting; Incorrect time range selection | Adjust time setting dial; Verify time range selection. |
8. Especificacións
Key technical specifications for the AUTONICS AT11DN-24-240 Multi-Function Timer:
| Característica | Especificación |
|---|---|
| Número de modelo | AT11DN-24-240 |
| Marca | AUTONICS |
| Intervalo de tempo | De 0.05 segundos a 100 horas |
| Vol. Subministracióntage | 100VAC - 240VAC |
| Consumo de enerxía | 1.5 W |
| Tipo de saída | Relay Output (1c) |
| Valoración de contacto | 5A Resistive Load |
| Reset Time | 100 ms |
| Material | Plástico |
| Dimensións do paquete | 4.49 x 3.19 x 2.28 polgadas |
| Peso do elemento | 4.41 onzas |
9. Garantía e soporte
AUTONICS products are manufactured under strict quality control standards. For specific warranty terms and conditions, please refer to the warranty information provided with your purchase or visit the official AUTONICS website. For technical assistance, troubleshooting beyond this manual, or repair services, please contact AUTONICS customer support or your authorized distributor.