SIEMENS BQD345

Siemens BQD345 45-Amp Interruptor de circuíto tripolar

Manual de instrucións

1. Introdución

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Siemens BQD345 45-Amp Three Pole Circuit Breaker. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.

2. Información de seguridade

AVISO: Electrical shock hazard. Installation and servicing of this equipment must be performed by qualified personnel only. Always disconnect power at the main service panel before working with circuit breakers or electrical panels.

  • Asegúrese de que se cumpran todos os códigos eléctricos locais e nacionais durante a instalación.
  • Do not install damaged equipment. Inspect the circuit breaker for any signs of damage before installation.
  • Never attempt to bypass or modify the circuit breaker's protective functions.
  • Siemens strongly recommends against the use of 'used' breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so.

3. Produto rematadoview

The Siemens BQD345 is a 45-Amp, three-pole, bolt-in type circuit breaker designed for panel board mounting. It is rated for 480Y/277V AC with a 14KAIC interrupting rating. This thermal-magnetic circuit breaker provides overcurrent protection for electrical circuits.

Características principais:

  • Type BQD
  • Three Pole Configuration
  • 45 Amps Current Rating
  • 480Y/277V AC Voltage Avaliación
  • 14KAIC Interrupting Rating
  • Montaxe de placa de panel (aparafusada)
  • Listado UL

Imaxes do produto:

Siemens BQD345 45-Amp Three Pole Circuit Breaker, main view
Figura 3.1: Principal view of the Siemens BQD345 circuit breaker, showing its overall structure and terminals.
Siemens BQD345 45-Amp Three Pole Circuit Breaker, front view con etiquetas
Figura 3.2: Fronte view of the BQD345 circuit breaker, highlighting the Siemens branding, specifications, and the ON/OFF/TRIP indicator.
Siemens BQD345 45-Amp Three Pole Circuit Breaker, side view
Figura 3.3: Lado view of the BQD345 circuit breaker, showing the mounting points and general profile.
Siemens BQD345 45-Amp Three Pole Circuit Breaker, rear view con terminais
Figura 3.4: Traseira view of the BQD345 circuit breaker, displaying the bolt-in terminals and product identification barcode (OM-1962015-1Q-2546).

4. Configuración e instalación

The Siemens BQD345 circuit breaker is designed for bolt-in installation within a compatible panel board. Installation must be performed by a qualified electrician in accordance with all applicable electrical codes.

  1. Desconexión de alimentación: Before beginning any work, ensure that all power to the electrical panel is completely disconnected at the main service entrance. Verify with a voltagprobador.
  2. Acceso ao panel: Retire con coidado a tapa do panel eléctrico para expoñer as barras colectoras e a área de cableado.
  3. Montaxe: Position the BQD345 circuit breaker onto the designated bus bar connections in the panel board. Securely fasten the breaker using the bolt-in mechanism.
  4. Cableado: Connect the load wires to the appropriate terminals on the circuit breaker. Refer to the breaker's label for correct wire sizing (e.g., for 45A, Cu-Al 60°/75°C wire, size 8 AWG for 45A). Ensure all connections are tight and secure.
  5. Remontaxe do panel: Once wiring is complete and verified, replace the panel cover.
  6. Restauración de enerxía: Restore power at the main service entrance.

For detailed wiring diagrams and specific panel compatibility, consult the panel board manufacturer's instructions and relevant electrical codes.

5. Instrucións de funcionamento

The BQD345 circuit breaker features a toggle handle that indicates its current status:

  • ACTIVADO: The handle is in the 'ON' position, indicating that power is flowing through the circuit.
  • OFF: The handle is in the 'OFF' position, indicating that power to the circuit is disconnected.
  • VIAXE: If an overcurrent or short circuit condition occurs, the breaker will automatically move to the 'TRIP' position (typically a central position between ON and OFF). This indicates that the circuit has been interrupted for safety.

To reset a tripped breaker: First, move the handle completely to the 'OFF' position, then push it firmly to the 'ON' position. If the breaker immediately trips again, there is likely a persistent fault in the circuit that requires investigation by a qualified electrician.

6. Mantemento

Un mantemento regular axuda a garantir a lonxevidade e o funcionamento fiable do interruptor automático. Todo o mantemento debe ser realizado por persoal cualificado coa alimentación desconectada.

  • Inspección visual: Periodically inspect the circuit breaker and its connections for any signs of overheating, discoloration, loose wires, or physical damage.
  • Limpeza: Keep the area around the circuit breaker clean and free of dust and debris. Use a dry, non-conductive cloth for cleaning.
  • Proba: While not typically required for residential or light commercial applications, some industrial standards may require periodic testing of circuit breakers. Consult relevant standards and a qualified electrician for such requirements.

7 Solución de problemas

If your Siemens BQD345 circuit breaker is not functioning as expected, consider the following:

  • Disparos frecuentes do disyuntor: This indicates an overcurrent condition or a short circuit in the protected circuit. Disconnect all loads from the circuit and try resetting the breaker. If it still trips, there is a fault in the wiring or a connected appliance. Consult a qualified electrician.
  • O disxuntor non se reinicia: Ensure the handle is pushed fully to the 'OFF' position before attempting to move it to 'ON'. If it still won't reset, or immediately trips, a fault is present.
  • Sen alimentación ao circuíto (disxuntor activado): Check the main service panel for tripped main breakers. Verify all connections to the BQD345 are secure. If the issue persists, professional electrical diagnosis is required.

Do not attempt to force a breaker into the ON position if it resists or immediately trips. This can indicate a serious electrical fault.

8. Especificacións

AtributoValor
MarcaSIEMENS
Número de modeloBQD345
Valoración actual45 Amps
Número de polos3
Voltage Avaliación480Y/277V AC
Clasificación de interrupción14KAIC
Tipo de interruptor automáticoTermomagnético, estándar
Tipo de montaxePanel Mount (Bolt-in)
Peso do elemento1.81 libras
Dimensións do produto4 x 3 x 3 polgadas
UPC783643277403
Compoñentes incluídosCircuit Breaker, 45A, Bolt On, 480V, 3P

9. Garantía e soporte

Información da garantía:

Siemens strongly recommends against the use of "used" breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so. For specific warranty terms and conditions, please refer to the official Siemens warranty documentation or contact Siemens customer support.

Atención ao cliente:

Para asistencia técnica, consultas sobre produtos ou reclamacións de garantía, visite o sitio web oficial de Siemens website or contact their customer service department. Ensure you have your product model number (BQD345) and any relevant purchase information available when contacting support.

Documentos relacionados - BQD345

Preview Interruptores automáticos Siemens WL: Guía de selección e aplicación
Guía completa de Siemens WL Low VoltagInterruptores automáticos, que abarcan a selección, aplicación, características, especificacións e accesorios para produtos listados con UL489 e UL1066.
Preview Interruptores de circuíto de alimentación Siemens WL: guía completa e especificacións
Explore a serie WL de interruptores automáticos de Siemens, con detalles das características, conformidade coas normas UL 489 e UL 1066, unidades de disparo electrónicas (ETU), accesorios e especificacións técnicas para a distribución de enerxía industrial.
Preview Siemens Low VoltagInstrucións de funcionamento do interruptor automático de potencia UL 1066
Instrucións de funcionamento completas para Siemens Low VoltagInterruptores de circuíto de potencia, concretamente a serie UL 1066. Esta guía abrangue a instalación, a posta en servizo, o mantemento e as especificacións técnicas destes interruptores e os seus soportes asociados.
Preview Dispositivos de protección de enerxía Siemens: MCB, RCCB, MCCB, ACB - Produto sobreview e detalles técnicos
Rematada integralview de dispositivos de protección de circuítos Siemens SENTRON e SINOVA, incluíndo interruptores miniatura (MCB), interruptores de corrente residual (RCCB), interruptores de caixa moldeada (MCCB) e interruptores de circuíto en aire (ACB). Detalla as carteiras de produtos, as especificacións técnicas, as aplicacións e as características de seguridade.
Preview Interruptor automático Siemens con unidade de disparo termomagnética: instrucións de funcionamento
Instrucións de funcionamento completas para os interruptores automáticos da serie 3VA51 de Siemens, que detallan as advertencias de seguridade, os procedementos de instalación, as opcións de conexión e as especificacións técnicas.
Preview Programa e servizos de mantemento de interruptores automáticos TCP tipo Siemens
Guía completa para o mantemento de interruptores automáticos SF6 tipo TCP de Siemens, incluíndo intervalos de mantemento importantes, servizo de campo, formación, pezas de renovación, actualizacións e consellos para a resolución de problemas.