Tree LCT33

Manual do usuario da báscula de conteo grande Tree LCT 33

Modelo: LCT33

1. Introdución

Thank you for choosing the Tree LCT 33 Large Counting Scale. This precision instrument is designed for accurate counting and weighing of various items, from small components like jewelry and coins to bulk materials such as chemicals and powders. With its high sensitivity and robust design, the LCT 33 is an ideal tool for inventory management, quality control, and packaging applications. This manual provides detailed instructions for the proper setup, operation, and maintenance of your scale to ensure optimal performance and longevity.

2. Información de seguridade

Please read and understand all safety instructions before operating the scale. Failure to do so may result in damage to the unit or personal injury.

3. Contido do paquete

Verifica que todos os elementos estean presentes no paquete:

4. Produto rematadoview

4.1 Fronte View

Fronte view of the Tree LCT 33 Counting Scale, showing the stainless steel platter, LCD display, and control keypad.

This image displays the main components visible from the front: the large stainless steel weighing pan, the green backlit LCD display, and the comprehensive control keypad with numeric and function keys.

4.2 Laterais View

Lado view of the Tree LCT 33 Counting Scale, showing the adjustable leveling feet and the integrated bubble level.

O lado view highlights the low-profile design of the scale, along with the adjustable leveling feet and the built-in bubble level, crucial for ensuring accurate measurements.

4.3 Traseira View

Traseira view of the Tree LCT 33 Counting Scale, showing the power input port and the power switch.

The rear of the scale features the DC 12V power input port and the main power ON/OFF switch. A label reminds users to 'Use factory adapter only'.

4.4 Teclado e pantalla

Close-up of the Tree LCT 33 Counting Scale's keypad and display, showing the various function keys and the multi-segment LCD.

The intuitive keypad includes numeric keys (0-9), memory keys (M1-M9), and dedicated function keys such as TAREAR, CERO, SAMPLE, QTY SET, TENDA, TOTAL, e CE (Clear Entry). The LCD screen simultaneously displays total weight, unit weight, and piece count.

5. Configuración

  1. Desembalaxe: Carefully remove the scale and all components from the packaging. Retain the packaging for future storage or transport.
  2. Colocación: Place the scale on a firm, stable, and level surface, free from vibrations and drafts.
  3. Nivelación: Adjust the four adjustable feet at the bottom of the scale until the bubble in the built-in level indicator is centered. This is critical for accurate measurements.
  4. Conexión de alimentación: Connect the AC power adapter to the DC 12V input port on the rear of the scale, then plug the adapter into a suitable power outlet. The scale can also operate on its internal rechargeable battery.
  5. Encendido inicial: Flip the power switch on the rear of the scale to the 'ON' position. The display will perform a self-test and then show '0.0000' or '0.000' depending on the unit.

6. Funcionamento

6.1 Pesaxe básica

  1. Ensure the scale is powered on and displays '0.0000'. If not, press the CERO chave.
  2. Place the item(s) to be weighed onto the center of the stainless steel weighing pan.
  3. Read the weight displayed in the 'WEIGHT' section of the LCD.

6.2 Función de conteo

The counting function allows you to determine the number of pieces based on a sample unit weight.

  1. Place a known quantity of items (e.g., 10, 20, 50, 100 pieces) onto the weighing pan. This is your sample.
  2. Preme o SAMPLE key. The display will prompt you to enter the sampa cantidade.
  3. Using the numeric keypad, enter the exact number of sample pieces you placed on the pan.
  4. Preme o QTY SET key to confirm. The scale will calculate and store the unit weight of the sample.
  5. Elimina o sample pieces. The display should return to '0' in the 'TOTAL (pcs)' section.
  6. Place the items you wish to count onto the pan. The 'TOTAL (pcs)' display will show the total number of pieces.

6.3 Función de tara

The tare function allows you to subtract the weight of a container or packaging, so only the net weight of the contents is measured.

  1. Place the empty container onto the weighing pan. The display will show its weight.
  2. Preme o TAREAR key. The display will reset to '0.0000', indicating the container's weight has been tared out.
  3. Add the items to be weighed into the container. The display will now show only the net weight of the items.
  4. To clear the tare, remove the container and press the TAREAR chave de novo.

6.4 Memory Functions (M1-M9)

The scale features 9 memory keys (M1-M9) to store and recall frequently used unit weights or tare values.

  1. To Store a Unit Weight: After setting a unit weight using the counting function (Section 6.2), press the TENDA key, then press the desired memory key (M1-M9) to save the unit weight.
  2. To Recall a Unit Weight: Press the desired memory key (M1-M9). The stored unit weight will be loaded, and the scale will be ready for counting based on that unit weight.

7. Calibración

The Tree LCT 33 scale is factory calibrated. However, if you suspect inaccuracies or after significant environmental changes, recalibration may be necessary. For detailed calibration procedures, please refer to the separate calibration guide or contact Tree customer support. It is recommended to use certified calibration weights for this process.

8. Mantemento

9 Solución de problemas

ProblemaCausa posibleSolución
A escala non se acende.No power; battery depleted; power adapter faulty.Check power connection. Charge battery. Try a different outlet.
Lecturas inexactas.Scale not level; unstable surface; drafts; calibration needed.Adjust leveling feet. Move to stable surface. Avoid drafts. Recalibrate if necessary.
Display shows 'OVERLOAD'.O peso supera a capacidade máxima.Remove excess weight immediately.
Counting function is incorrect.Incorrecto sample quantity entered; inconsistent unit weight of items.Re-enter correct sample quantity. Ensure items have uniform weight.

10. Especificacións

CaracterísticaDetalle
ModeloLCT33
Capacidade33 libras (15 kg)
Readability (Division)0.001 libras (0.5 g)
Weighing Pan Dimensions13" x 9" (33 cm x 22.87 cm)
Dimensións xerais do produtoApprox. 13.75" (L) x 13.25" (W) x 4.125" (H)
Tipo de visualizaciónLCD retroiluminado
Fonte de enerxíaAC Adapter (DC 12V, 1A) or Built-in Rechargeable Battery
MaterialPlastic housing, Stainless Steel platter
Características especiaisHigh Sensitivity, Precision, Bubble Level, Low-Profile Design, 9 Memory Keys
Peso do elemento8 libras
UPC855736005344

10.1 Diagrama de dimensións

Diagram showing the dimensions of the Tree LCT 33 Counting Scale in inches and centimeters.

This diagram provides a visual representation of the scale's key dimensions, including length, width, and height, in both inches and centimeters.

11. Garantía e soporte

The Tree LCT 33 Large Counting Scale comes with a 2 anos de garantía do fabricante desde a data de compra. Esta garantía cobre defectos de materiais e fabricación en condicións de uso normal.

For technical assistance, troubleshooting, or warranty claims, please contact Tree customer support. Our team provides real USA customer support to assist you with any questions or issues you may encounter.

For the most up-to-date contact information, please visit the official Tree websitio web ou consulte a documentación da súa compra.

Documentos relacionados - LCT33

Preview TREE SCT Series Small Counting Scale: Operating Manual
This operating manual provides detailed instructions for the TREE SCT Series Small Counting Scales, covering setup, operation, features, calibration, maintenance, and troubleshooting for models SCT 600, SCT 1200, SCT 7, SCT 16, and SCT 33.
Preview LCTx Series Large Counting Scale Operating Manual
Operating manual for the TREE LCTx Series Large Counting Scales, covering specifications, features, operation, calibration, maintenance, and troubleshooting.
Preview DCT Series Dual Counting Scale Operating Manual
Operating manual for the TREE DCT Series Dual Counting Scales (DCT 50, DCT 110) by LW Measurements LLC, covering features, functions, setup, calibration, and troubleshooting.
Preview LSS Series Large Shipping Scale Operating Manual - TREE by LW Measurements
Operating manual for the TREE LSS Series Large Shipping Scales (Models LSS 200 and LSS 400) by LW Measurements LLC. This guide provides detailed instructions on setup, operation, calibration, maintenance, and troubleshooting for professional weighing applications.
Preview LWC Series Large Wheelchair Scale Operating Manual
Operating manual for the TREE LWC Series Large Wheelchair Scale (Model LWC 1000) by LW Measurements LLC. Covers features, specifications, assembly, operation, calibration, maintenance, and troubleshooting.
Preview LC-VS Series Low-Cost Vet Scale Operating Manual
Operating manual for the TREE LC-VS Series Low-Cost Vet Scale, Model LC-VS 60. Provides detailed instructions on features, functions, calibration, maintenance, and troubleshooting for professional weighing equipment.