1. Introdución
This manual provides essential information for the safe and effective use of the OSRAM SYLVANIA HXP R 120 W/45 C VIS (69119) 120W CLEAR Mercury-Arc-Lamp. This high-intensity discharge (HID) lamp features a short arc with a reflector, a special base, and a specialized connector cable with a plug for secure mating and locking. Designed for specific applications, it offers a lifespan of 2000 hours, a 22.4-degree beam angle, and a color temperature of 9500 Kelvin. Its compact design includes a 2.638-inch (67mm) diameter and a 77mm MOL (Maximum Overall Length), delivering 2800 lumens. The lamp operates on AC current and is capable of hot restart, with an optimal operating position of horizontal plus or minus 20 degrees and a 45mm working distance.
2. Información de seguridade
Please read and understand all safety warnings before installing, operating, or maintaining this lamp. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Alto Voltage: Este lamp opera a alto voltage. A instalación e o mantemento só deben ser realizados por persoal cualificado.
- Alta temperatura: O lamp operates at extremely high temperatures. Allow the lamp to cool completely before handling or performing any maintenance. Avoid contact with hot surfaces.
- Radiación UV: Este lamp emits ultraviolet (UV) radiation. Avoid direct exposure to the lamp when operating. Use appropriate shielding and eye protection.
- Lamp Rupture: HID lamps can rupture if mishandled, improperly installed, or operated beyond their rated life. Always wear protective eyewear and gloves when handling.
- Eliminación: Mercury-arc lamps contain mercury. Dispose of lamps according to local, state, and federal regulations. Do not dispose of in regular household waste.
- Compatibilidade: Asegurar o lamp is compatible with the fixture and ballast before installation. Incorrect ballast or fixture can lead to lamp failure or safety hazards.
3. Produto rematadoview
3.1 Características principais
- Short Arc with integrated reflector for precise light control.
- Special Base and Connector Cable with Plug (Mate & Lock) for secure electrical connection.
- Longa vida útil de 2000 horas.
- High color temperature of 9500 Degrees Kelvin.
- Hot Restart capability.
- Clear finish for optimal light output.
3.2 Lamp Compoñentes
The OSRAM SYLVANIA HXP R 120 W/45 C VIS lamp consists of a compact arc tube, an integrated reflector, a specialized base, and a connector cable with a plug designed for a secure 'mate and lock' connection to compatible fixtures.

Image: OSRAM SYLVANIA HXP R 120W Mercury-Arc-Lamp. This image shows the compact design of the lamp, highlighting its integrated reflector and specialized base with the connector cable.
4. Configuración e instalación
Due to the specialized nature and high-intensity output of this lamp, professional installation by a qualified technician is highly recommended.
4.1 Comprobacións previas á instalación
- Ensure the power to the fixture is completely disconnected before beginning installation.
- Verify that the fixture is compatible with the OSRAM SYLVANIA HXP R 120W lamp, incluíndo o volumetage, wattage, and base type.
- Inspeccione o lamp for any visible damage. Do not install a damaged lamp.
- Usar equipos de protección individual (EPI) axeitados, incluíndo luvas e protección ocular.
4.2 Procedemento de instalación
- Retire coidadosamente a nova lamp from its packaging, holding it by the base or reflector, avoiding contact with the glass envelope.
- Align the special base and connector cable with the corresponding receptacle in the fixture.
- Insira suavemente o lamp and engage the 'mate and lock' mechanism of the connector cable and plug until it is securely fastened. Do not force the connection.
- Asegurar o lamp is positioned within the recommended operating angle of horizontal plus or minus 20 degrees.
- Once installed, ensure all fixture covers and safety shields are properly secured.
5. Instrucións de funcionamento
- Encendido: After installation, restore power to the fixture. The lamp will ignite and begin its warm-up cycle.
- Tempo de quecemento: HID lamps require a brief warm-up period to reach full brightness and stable color. This typically takes a few minutes.
- Hot Restart: Este lamp is designed with a 'Hot Restart' capability, meaning it can be re-ignited shortly after being turned off, without a prolonged cooling period. However, frequent hot restarts can reduce lamp vida.
- Posición Operativa: Manter o lamp within its specified operating position of horizontal plus or minus 20 degrees for optimal performance and lifespan.
- Apagado: Para apagar o lamp, disconnect power to the fixture.
6. Mantemento
Regular maintenance ensures optimal performance and extends the life of your lamp. Always disconnect power and allow the lamp to cool completely before performing any maintenance.
- Limpeza: Limpar periodicamente o lamp's reflector and glass envelope with a soft, lint-free cloth. If necessary, use a mild glass cleaner applied to the cloth, not directly to the lamp. Ensure no residue remains.
- Inspección: Inspeccione regularmente o lamp and its connections for any signs of wear, damage, or discoloration. Replace the lamp if any damage is observed.
- Substitución: O lamp has a rated life of 2000 hours. It is recommended to replace the lamp proactively near the end of its rated life to prevent unexpected failure or reduced performance.
- Eliminación: When replacing, dispose of the old lamp according to environmental regulations for mercury-containing products.
7 Solución de problemas
If you encounter issues with your OSRAM SYLVANIA HXP R 120W lamp, consulta os seguintes pasos habituais para a resolución de problemas:
- Lamp Non acende:
- Comprobe se a subministración de enerxía do dispositivo está activa.
- Asegurar o lamp is correctly and securely seated in its receptacle.
- Verify the fixture's ballast is functioning correctly.
- O lamp pode que chegara ao final da súa vida útil e precise ser substituído.
- Luz tenue ou parpadeante:
- Allow sufficient warm-up time for the lamp para alcanzar o brillo total.
- Comprobar o volume adecuadotage subministración ao dispositivo.
- O lamp may be nearing the end of its operational life.
- Lamp Cycles On and Off:
- Isto indica a miúdo a lamp is at the end of its life and should be replaced.
- Ensure the fixture is not overheating due to poor ventilation.
If these steps do not resolve the issue, contact a qualified technician or OSRAM customer support for further assistance.
8. Especificacións
| Especificación | Valor |
|---|---|
| Marca | OSRAM |
| Número de modelo | NCOREJNJIJKKM6322 |
| Tipo de luz | Mercury-Arc (HID) |
| Wattage | 120 vatios |
| Voltage | 120 voltios |
| Vida útil | 2000 horas |
| Temperatura da cor | 9500 Degrees K |
| Fluxo luminoso | 2800 lúmenes |
| Ángulo do feixe | 22.4 graos |
| Diámetro | 2.638 polgadas (67 mm) |
| MOL (Maximum Overall Length) | 77 mm |
| Posición Operativa | Horizontal Plus or Minus 20 Degrees |
| Distancia de traballo | 45 mm |
| Método de control | Aplicación (Note: This refers to the system the lamp is integrated into, not the lamp en si.) |
| Peso do elemento | 5.6 onzas |
| Dimensións do produto | 2.64" de ancho x 2.64" de alto |
9. Garantía e soporte
For specific warranty information regarding your OSRAM SYLVANIA HXP R 120 W/45 C VIS lamp, please refer to the documentation provided with your purchase or visit the official OSRAM website. If you require technical support, have questions about installation, or need assistance with troubleshooting beyond what is covered in this manual, please contact OSRAM customer service directly. Ensure you have your product model number (NCOREJNJIJKKM6322) and purchase details available when contacting support.