1. Introdución
This manual provides essential information for the proper installation, operation, and maintenance of your ASHCROFT Vacuum Gauge. This test gauge is designed for precise vacuum measurement, featuring a durable construction suitable for industrial applications.
The gauge has a 2-1/2 inch dial, measures vacuum from 30 inches of Mercury (Hg) to 0, and features a 1/4 inch NPT connection located at the lower back. It is constructed with a 304 stainless steel case, 316 stainless steel socket and tube, and a polycarbonate lens. The gauge is filled with glycerin for dampening and enhanced performance.

Figura 1: ASHCROFT Vacuum Gauge. This image displays the front view of the vacuum gauge, highlighting its stainless steel casing, white dial with black markings, and the ASHCROFT DURALIFE branding. The gauge face indicates measurements in psi and notes "Welded AISI 316 tube & socket U.S.A."
2. Información de seguridade
Always observe standard safety precautions when handling and installing pressure and vacuum gauges. Failure to do so may result in injury or damage to equipment.
- Ensure the system is depressurized before installing or removing the gauge.
- Do not exceed the specified operating range of 30" Hg Vac to 0.
- Verify compatibility of the gauge's wetted parts (316 Stainless Steel) with the process media.
- Protect the gauge from extreme temperatures outside the -40°F to 150°F operating range.
- Handle with care to avoid dropping or impacting the gauge, which can affect accuracy.
3. Configuración e instalación
Proper installation is crucial for accurate readings and long service life.
- Preparación: Ensure the connection port on your system is clean and free of debris.
- Conexión: The gauge features a 1/4 inch NPT (National Pipe Taper) connection. Apply appropriate thread sealant (e.g., PTFE tape) to the male threads of the gauge connection.
- Montaxe: Carefully thread the gauge into the system's female NPT port. Tighten using a wrench on the wrench flats of the gauge connection. Do not overtighten or apply torque to the gauge case.
- Orientación: The connection location is lower back, allowing for direct mounting or panel mounting with appropriate accessories (not included). Ensure the dial is easily visible for reading.
4. Instrucións de funcionamento
The ASHCROFT Vacuum Gauge provides accurate vacuum measurements within its specified range.
- Lectura do manómetro: The dial is marked from 30" Hg Vac (full vacuum) to 0 (atmospheric pressure). The smallest graduation is 0.5" Hg, allowing for precise readings.
- Precisión: This gauge has an accuracy of +/-1.0% of span, ensuring reliable measurements for test applications.
- Consideracións de temperatura: The gauge is designed to operate effectively within a temperature range of -40°F to 150°F. Operating outside this range may affect accuracy and longevity.
- Glycerin Fill: The glycerin fill dampens pointer pulsation caused by vibration and pressure surges, improving readability and extending the life of the gauge movement.
5. Mantemento
Regular maintenance ensures the longevity and accuracy of your vacuum gauge.
- Limpeza: Clean the exterior of the gauge, especially the polycarbonate lens, with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the lens or case.
- Inspección: Periodically inspect the gauge for any signs of damage, such as cracks in the lens, dents in the case, or bent pointer. Check the connection for leaks.
- Recalibración: While designed for long-term accuracy, professional recalibration may be necessary if the gauge is subjected to severe conditions or if accuracy is critical for your application.
- Almacenamento: When not in use, store the gauge in a clean, dry environment within its operating temperature range.
6 Solución de problemas
Consulta os seguintes problemas comúns e as súas posibles solucións:
| Problema | Causa posible | Solución |
|---|---|---|
| Lectura inexacta | Gauge exposed to over-vacuum; physical damage; extreme temperature. | Verify operating conditions; inspect for damage; allow gauge to normalize temperature. Consider professional recalibration or replacement. |
| Pointer Fluctuation | System vibration; rapid pressure changes. | The glycerin fill helps dampen this; ensure gauge is securely mounted. If severe, consider a snubber or remote mounting. |
| Leak at Connection | Improperly applied thread sealant; insufficient tightening. | Depressurize system, remove gauge, reapply thread sealant, and re-install, ensuring proper tightening. |
7. Especificacións
Detailed technical specifications for the ASHCROFT Vacuum Gauge (Model: 251009SW02BXLLVAC).
- Tipo de indicador: Proba
- Tamaño da esfera: 2-1/2 polgadas
- Rango: 30" Hg Vac to 0
- Tamaño da conexión: 1/4" NPT
- Lugar de conexión: Baixa das costas
- Smallest Graduation: 0.5" Hg
- Precisión: +/-1.0 %
- Material da caixa: Aceiro inoxidable 304
- Cor da caixa: Prata
- Material do enchufe: Aceiro inoxidable 316
- Material do tubo: Aceiro inoxidable 316
- Encher: Glicerina
- Material da lente: Policarbonato
- Ring Material: Aceiro inoxidable
- Rango de temperatura de funcionamento: -40 °F a 150 °F
- Serie: 1009
- Dimensións do produto: 3 x 3 x 3 polgadas
- Peso do artigo: 1 libra
- País de orixe: EUA
- UPC: 094706106517
8. Garantía e soporte
This ASHCROFT Vacuum Gauge comes with a 5 anos de garantía do fabricante. For warranty claims or technical support, please contact ASHCROFT customer service. Retain your proof of purchase for warranty validation.
For further assistance or detailed technical inquiries, please refer to the official ASHCROFT websitio web ou póñase en contacto cos seus distribuidores autorizados.