YELLOW JACKET 93560

YELLOW JACKET 93560 Superevac Single Phase Pump Instruction Manual

Modelo: 93560

Marca: CHAQUETA AMARELA

Produto rematadoview

The YELLOW JACKET 93560 Superevac Single Phase Pump is a highly efficient, two-stage rotary vane oil-sealed pump designed for professional use. It is field-rated at 15 microns or better, indicating superior vacuum performance. This pump is engineered for ease of use and maintenance, featuring several innovative design elements.

YELLOW JACKET 93560 Superevac Single Phase Pump

Image: The YELLOW JACKET 93560 Superevac Single Phase Pump, a robust silver-colored unit with a black motor housing, a carrying handle, and a vacuum indicator gauge on the top surface. The "YELLOW JACKET Superevac 6" logo is visible on the side.

Características principais:

  • Isolation Valve: Allows for oil changes without losing vacuum in the system.
  • Built-in Vacuum Indicator Gauge: Provides real-time vacuum level monitoring.
  • Wide-Mouth Oil Reservoir Port: Facilitates easier and cleaner oil filling. This port also doubles as the pump exhaust and is threaded to attach a garden hose for remote exhausting.
  • Large Oil Sight Glass: Enables easy monitoring of the oil level.
  • Large Brass Oil Drain: Designed for easy access and fast oil changes.

Configuración e instalación

Before operating the YELLOW JACKET 93560 Superevac pump, ensure all components are present and undamaged. Follow these steps for proper setup:

  1. Desembalaxe: Retire con coidado a bomba da súa embalaxe. Inspeccione se hai algún dano visible que se poida producir durante o envío.
  2. Colocación: Position the pump on a stable, level surface in a well-ventilated area. Ensure adequate clearance around the pump for air circulation and access for maintenance.
  3. Recheo de aceite: The pump may be shipped without oil or with a small amount for testing. Before first use, fill the oil reservoir with the recommended vacuum pump oil. Use the wide-mouth oil reservoir port for clean filling. Monitor the oil level through the large oil sight glass. Do not overfill.
  4. Conexión de alimentación: Connect the pump to a grounded 115V, 60 Hz power outlet. Ensure the power supply matches the pump's requirements.
  5. Verificación inicial: Before connecting to a system, briefly turn on the pump to ensure it operates smoothly and quietly. Observe the oil level and ensure no leaks are present.

Instrucións de funcionamento

The Superevac pump is designed for efficient evacuation of refrigeration and air conditioning systems. Follow these guidelines for optimal performance:

  1. Conexión do sistema: Connect the pump to the system requiring evacuation using appropriate vacuum hoses and fittings. Ensure all connections are tight to prevent leaks.
  2. Posta en marcha: Turn on the pump. The built-in vacuum indicator gauge will begin to show the vacuum level as the pump operates.
  3. Monitorización do baleiro: Continuously monitor the vacuum indicator gauge to ensure the desired vacuum level is achieved. The pump is field-rated at 15 microns or better.
  4. Using the Isolation Valve: The isolation valve allows for oil changes without breaking the vacuum in the system. To change oil during operation, close the isolation valve, perform the oil change, and then reopen the valve.
  5. Xestión de escape: The wide-mouth oil reservoir port doubles as the pump exhaust. If desired, a garden hose can be threaded onto this port to direct exhaust to a remote location, especially in confined spaces or when dealing with large amounts of moisture.
  6. Apagado: Once the desired vacuum is achieved and maintained, close the system's service valves. Turn off the pump and disconnect the hoses.

Mantemento

Regular maintenance is crucial for the longevity and optimal performance of your YELLOW JACKET 93560 Superevac pump. Adhere to the following maintenance schedule:

  • Cambios de aceite:
    • Change the vacuum pump oil frequently, especially after evacuating systems with high moisture content. Dirty or contaminated oil reduces pump efficiency and can cause damage.
    • To change oil, ensure the pump is off and cool. Place a suitable container under the large brass oil drain. Open the drain plug to allow the old oil to flow out.
    • Once drained, close the plug and refill with new, clean vacuum pump oil through the wide-mouth oil reservoir port. Use the oil sight glass to ensure the correct level.
  • Monitorización do nivel de aceite: Regularly check the oil level through the large oil sight glass. Maintain the oil level between the minimum and maximum indicators.
  • Limpeza: Keep the exterior of the pump clean and free of dust and debris. Ensure cooling fins are not obstructed to prevent overheating.
  • Filtro de entrada: Periodically inspect and clean or replace the inlet filter (if applicable) to prevent contaminants from entering the pump.
  • Almacenamento: When not in use for extended periods, drain the oil and store the pump in a dry, clean environment. Cap all ports to prevent contamination.

Resolución de problemas

This section provides solutions to common issues you might encounter with your Superevac pump. For problems not listed here, contact customer support.

ProblemaCausa posibleSolución
A bomba non arrancaNo power, faulty power cord, motor issue.Check power connection and outlet. Inspect power cord for damage. If issues persist, contact service.
A bomba non fai suficiente baleiroContaminated or low oil, leaks in system/hoses, clogged inlet.Change oil. Check all connections for leaks. Inspect and clean inlet.
Ruído ou vibración excesivosNivel de aceite baixo, compoñentes desgastados, bomba non nivelada.Check and add oil. Ensure pump is on a stable, level surface. If noise persists, professional inspection may be needed.
Néboa de aceite do escapeHigh moisture content in system, overfilled oil.Ensure system is dry before evacuation. Check oil level and drain if overfilled. Consider using an exhaust filter or directing exhaust remotely.

Especificacións

Detailed technical specifications for the YELLOW JACKET 93560 Superevac Single Phase Pump:

  • Número de modelo: 93560
  • Marca: CHAQUETA AMARELA
  • Fabricante: Ritchie Engineering Co.
  • Voltage: 115 voltios (CA)
  • Frecuencia: 60 Hz
  • Caudal: 6 CFM (pés cúbicos por minuto)
  • Aspirador definitivo: 15 Microns or better
  • Peso do artigo: 31.5 libras
  • Dimensións do paquete: 19.1 x 14.1 x 8.4 polgadas
  • Material: Brass (components)
  • Cor: Amarelo (acentos)
  • Fonte de enerxía: Eléctrico con cable

Garantía e Soporte

The YELLOW JACKET 93560 Superevac Single Phase Pump is manufactured by Ritchie Engineering Co. For specific warranty information, technical support, or service inquiries, please contact Ritchie Engineering Co. directly or refer to the warranty card included with your product.

Recoméndase gardar o recibo de compra como xustificante de compra para reclamacións de garantía.

For additional support, you may also visit the official YELLOW JACKET websitio web ou póñase en contacto co seu distribuidor autorizado.

Documentos relacionados - 93560

Preview Yellow Jacket SuperEvac Vacuum Pump Operation and Maintenance Manual
Comprehensive operation and maintenance manual for Yellow Jacket SuperEvac vacuum pumps (Models 9354x, 9356x, 9358x, 9359x). Covers features, purpose, startup, troubleshooting, parts, and warranty.
Preview Yellow Jacket Series 41 Digital Manifold Quick Start Guide
A quick start guide for the Yellow Jacket Series 41 Digital Manifold, detailing its key functions, operation modes, unit settings, battery capacity, and supported refrigerants.
Preview Yellow Jacket P51-870 TITAN Digital Manifold Quick Start Guide
A quick start guide for the Yellow Jacket P51-870 TITAN Digital Manifold, covering operation modes, settings, and data management.
Preview YJACK MANO™ Dual Port Manometer Quick Start Guide | YELLOW JACKET 67068
Quick start guide for the YELLOW JACKET YJACK MANO™ Dual Port Manometer (Model 67068), featuring Bluetooth® sensing technology. Learn how to power on, connect, view static pressure readings, use the YJACK VIEW™ app, and understand measurement ranges for HVAC applications.
Preview Yellow Jacket 69373 Combustible Gas Leak Detector Instruction and Operation Manual
Comprehensive instruction and operation manual for the Yellow Jacket 69373 handheld combustible gas leak detector. Covers features, specifications, battery installation, operating instructions, maintenance, troubleshooting, and warranty.
Preview Yellow Jacket CA502 Combustion Analyzer Quick Guide - Operation and Features
Comprehensive quick guide for the Yellow Jacket CA502 Combustion Analyzer. Learn about its features, how to perform combustion analysis, draft measurements, CO air monitoring, use memory functions, and printing options. Includes setup and operational instructions.