Extech MS6100

Extech MS6100 2-Channel Digital Oscilloscope User Manual

Modelo: MS6100

1. Introdución

This manual provides comprehensive instructions for the safe and effective operation of the Extech MS6100 2-Channel Digital Oscilloscope. The MS6100 is a versatile instrument designed for precise electrical testing and measurement, combining the functionalities of a digital oscilloscope and a TRMS multimeter.

Key features include a 5.6-inch color LCD, high sampling rate, extensive record length, and various measurement capabilities. Please read this manual thoroughly before using the device to ensure proper handling and to maximize its performance.

2. Información de seguridade

WARNING: To avoid electric shock or personal injury, read the safety information carefully before using the product.

3. Produto rematadoview

The Extech MS6100 integrates a powerful 2-channel digital oscilloscope with a full-featured TRMS multimeter, offering a compact and robust solution for field and bench measurements.

3.1 Características principais

3.2 Instrument Layout

Extech MS6100 2-Channel Digital Oscilloscope front view con pantalla e controis

Figura 3.1: Fronte view of the Extech MS6100 Digital Oscilloscope, showing the color LCD display, function buttons (F1-F5), navigation controls, input terminals (10A, FUSED/MAX 0.6A, mA, COM, V/Ω/C, CAT II 600V), and dedicated buttons for oscilloscope and multimeter functions.

The front panel features a large color LCD for displaying waveforms and measurement data. Below the screen are five function buttons (F1-F5) whose labels change dynamically on the screen. The main control area includes dedicated buttons for voltage (V), current (A), resistance (Ω), diode test, continuity, save/recall, utility, cursor, measure, and menu navigation. Input terminals for oscilloscope channels (CH1, CH2) and multimeter functions are located at the bottom, along with the power button and auto-setup button.

4. Configuración e funcionamento inicial

4.1 Desembalaxe e inspección

Carefully unpack the instrument and verify that all items are present and undamaged. The package should include:

4.2 Instalación e carga da batería

The MS6100 is powered by one Lithium Ion battery (included and pre-installed). Ensure the battery is fully charged before first use. Connect the universal AC adaptor/charger to the instrument's charging port and to a suitable AC power outlet. The charging indicator will show the charging status.

4.3 Acendido/Apagado

Para acender o dispositivo, manteña premido o botón Poder button (orange circle with power symbol) located at the bottom left of the control panel. To power off, press and hold the same button until the display shuts down.

4.4 Configuración inicial

Upon first power-on, the device may prompt for language selection or other initial settings. Use the navigation buttons and F-buttons to configure as needed. The built-in multi-language help system can be accessed via the pop-up menu.

5. Instrucións de funcionamento

5.1 Modo de osciloscopio

To enter Oscilloscope mode, press the OSC DMM button. The display will show the waveform grid and channel information.

5.2 Modo multímetro

To switch to Multimeter mode, press the OSC DMM button again. The display will show multimeter readings.

5.3 Almacenamento e recuperación de datos

The MS6100 allows for extensive data storage on its internal 2G microSD card.

6. Mantemento

6.1 Limpeza

Regular cleaning helps maintain the instrument's performance and appearance.

6.2 Coidado coa batería

Para prolongar a duración da batería:

6.3 Almacenamento

When not in use, store the MS6100 in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.

7 Solución de problemas

Esta sección ofrece solucións para problemas comúns que podes atopar. Se o problema persiste, ponte en contacto co servizo de atención ao cliente.

ProblemaCausa posibleSolución
O instrumento non se acende.Battery is depleted or not properly installed. Power adapter not connected or faulty.Charge the battery using the AC adapter. Ensure the battery is correctly seated. Check AC adapter connection.
Non se mostra ningunha forma de onda no modo de osciloscopio.Probe not connected, signal too small/large, incorrect time/div or volts/div settings, trigger not set correctly.Ensure probes are connected to the correct inputs and the signal source. Press AUTO. Adjust VOLTS/DIV and TIME/DIV. Adjust trigger level.
As lecturas do multímetro son imprecisas.Incorrect function selected, test leads not properly connected, faulty test leads.Verify the correct measurement function is selected. Ensure test leads are securely connected to the appropriate terminals. Try different test leads if available.
Cannot save data to microSD card.MicroSD card full, card error, or card not properly inserted.Check available space on the microSD card. Reinsert the card. Format the card (this will erase all data).

8. Especificacións

Detailed technical specifications for the Extech MS6100 Digital Oscilloscope.

ParámetroValor
FabricanteSistemas FLIR
Número de pezaMS6100
Peso do elemento5.5 libras
Dimensións do produto9.6 x 6.4 x 2 polgadas
Número de modelo do artigoMS6100
Baterías1 pilas de iones de litio necesarias (incluídas)
Estilo100 MHz
Cantidade do paquete do artigo1
Data de primeira dispoñibilidade6 de agosto de 2012
Ancho de banda100 MHz
Mostrar5.6" (142mm) color LCD
Samptaxa de ling500MS/s per channel
Duración do rexistro1M point per channel
Multimeter Display6000 count with analog bargraph

9. Garantía e soporte

9.1 Información da garantía

Extech instruments are warranted to be free from defects in parts and workmanship for a specified period from the date of shipment (typically one year). For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Extech website. This warranty does not cover damage from abuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling.

9.2 Soporte técnico

For technical assistance, troubleshooting, or service inquiries, please contact Extech customer support. Before contacting support, please have your product model number (MS6100) and a detailed description of the issue ready. You can find contact information on the official Extech websitio ou na documentación proporcionada coa súa compra.

Visita o Tenda Extech en Amazon para máis información e recursos.

Documentos relacionados - MS6100

Preview Guía do usuario do calibrador de corrente Extech PRC10
Guía completa do usuario para o calibrador de corrente Extech PRC10. Obtén información sobre as súas características, modos de funcionamento (medición, fonte), directrices de seguridade, especificacións e servizos de calibración de Extech Instruments, unha empresa de FLIR Systems.
Preview Extech SD200 3-Channel Datalogging Thermometer User Manual
User manual for the Extech SD200, a 3-channel temperature datalogger. Features include Type-K thermocouple support, SD card data storage, selectable sampling rates, and a wide temperature range. Learn about operation, advanced settings, specifications, and safety.
Preview Manual do usuario do temporizador dixital Extech 375475
Manual de usuario do temporizador dixital Extech 375475, que detalla a configuración, a programación e o funcionamento para controlar electrodomésticos.
Preview Manual de usuario del registrador de datos USB EXTECH 407760
Manual de usuario do sonómetro USB EXTECH 407760. Este documento proporciona información esencial sobre a introdución, o funcionamento e os procedementos de substitución da batería do dispositivo.
Preview Manual do usuario do medidor de humidade, temperatura, fluxo de aire e luxómetro 4 en 1 EXTECH 45170
Manual de usuario para o EXTECH 45170, un medidor 4 en 1 que mide humidade, temperatura, fluxo de aire e luz. Inclúe información sobre o funcionamento, as especificacións e a garantía.
Preview Manual de medición de radiación UV-AB Extech UV505
Manual de usuario completo para el medidor de radiación UV-AB Extech UV505. Inclúe instrucións operativas, técnicas específicas, información de seguridade e mantemento.