Drayton ZA5

Manual do usuario do actuador Drayton ZA5

Model: ZA5 (Part No. 27650)

Marca: Drayton

1. Produto rematadoview

The Drayton ZA5 replacement actuator is designed for compatibility with the Drayton 22mm 2-port motorised valve, specifically part number 27100. This actuator is a critical component in central heating systems, responsible for controlling the flow of water to a specific heating zone by opening and closing the associated valve.

Drayton ZA5 Zone Valve Actuator with 5-wire cable

An image showing the Drayton ZA5 Zone Valve Actuator, a white rectangular unit with a label detailing its specifications, connected to a black cable with five colored wires (red, orange, green, blue, grey) at the end.

2. Información de seguridade

Always prioritize safety when working with electrical and heating systems. Failure to follow these instructions could result in electric shock, fire, or personal injury.

  • WARNING: DISCONNECT SUPPLY BEFORE REMOVING COVER. Ensure the main electrical supply to the heating system is completely switched off at the consumer unit/fuse box before attempting any installation, maintenance, or removal of the actuator cover.
  • Installation should only be performed by a qualified electrician or heating engineer.
  • Do not operate the actuator if it appears damaged.
  • Asegúrese de que todas as conexións de cableado estean seguras e cumpran cos códigos eléctricos locais.
  • Keep the actuator dry and away from excessive moisture.

3. Características clave

  • Drayton Part Number: 27650
  • 5-Wire configuration for comprehensive control.
  • Direct replacement for the Drayton 27100 Motorised Valve actuator.
  • Designed for zone valve applications in central heating systems.

4. Especificacións técnicas

EspecificaciónValor
MarcaDrayton
Número de modelo27650
Dimensións do produto9.5 x 6 x 6 cm
Peso do elemento535 g
Voltage230 voltios
Frecuencia50 Hz
Consumo de enerxía6 vatios
Máx. Temperatura ambiente52°C
Presión máxima do sistema125 psi
Valoración do conmutador3(1)A

5. Guía de instalación

This section provides general guidance for replacing a Drayton ZA5 actuator. Always refer to the specific wiring diagrams provided with your heating system and consult a qualified professional if unsure.

Ferramentas necesarias:

  • Set de destornilladores
  • Pelacables/cortadores
  • Voltagprobador

Pasos de instalación:

  1. Apagado: Locate the main electrical supply to your central heating system and switch it off at the consumer unit/fuse box. Verify that power is off using a voltagprobador.
  2. Access Actuator: Identify the existing actuator on your 2-port motorised valve. It is typically secured by screws or clips.
  3. Desconectar o cableado: Carefully note or photograph the existing wiring connections. Disconnect the five wires from the terminal block.
  4. Eliminar o actuador antigo: Unscrew or unclip the old actuator from the valve body. The valve body itself usually remains in place.
  5. Instalar un novo actuador: Position the new Drayton ZA5 actuator onto the valve body, ensuring it aligns correctly. Secure it with the provided screws or clips.
  6. Conectar cableado: Connect the five wires of the new actuator to the terminal block, matching the connections noted in step 3. The typical wire colors and functions are:
    • Brown: Live (Switched Live from programmer/thermostat)
    • Azul: neutro
    • Verde/Amarelo: Terra
    • Orange: Switched Live (to boiler/pump)
    • Grey: Return (from valve microswitch)
  7. Cobertura segura: Ensure all wires are neatly tucked away and secure the actuator cover.
  8. Restaurar enerxía: Switch the main electrical supply back on.
  9. Sistema de proba: Test the heating system to ensure the actuator operates correctly, opening and closing the zone valve as commanded by the thermostat or programmer.

6. Instrucións de funcionamento

The Drayton ZA5 actuator operates automatically as part of your central heating system. It does not require manual intervention for its primary function.

  • When the thermostat calls for heat in the zone controlled by the valve, the actuator receives an electrical signal, causing it to open the valve.
  • Once the thermostat's set temperature is reached, or the heating program ends, the electrical signal is removed, and the actuator closes the valve, typically via a spring return mechanism.
  • A small lever or button may be present on the actuator for manual override or to check valve operation during installation. Refer to your heating system's overall manual for specific instructions on using this feature, if available.

7. Mantemento

The Drayton ZA5 actuator is designed to be maintenance-free under normal operating conditions. No user-serviceable parts are inside the unit.

  • Keep the exterior of the actuator clean and free from dust and debris. Use a dry cloth for cleaning.
  • Do not attempt to lubricate any internal components.
  • Periodically check the wiring connections for any signs of wear or looseness. Ensure power is off before inspecting connections.
  • If the actuator shows signs of damage or malfunction, it should be replaced by a qualified professional.

8 Solución de problemas

If you experience issues with your heating system that you suspect are related to the zone valve actuator, consider the following common problems and solutions:

ProblemaCausa posibleSolución
Sen calefacción na zonaActuator not opening valve; no power to actuator; faulty thermostat/programmer.Check thermostat setting. Verify power to actuator (with power off, check wiring). Replace actuator if it does not respond to power.
Zone always hot (heating won't turn off)Actuator stuck open; faulty microswitch in actuator; wiring fault.Check if actuator returns to closed position when power is off. If not, replace actuator. Check wiring for shorts.
Actuator makes buzzing noise but doesn't moveMotor fault; obstruction in valve.Replace actuator. Check valve for mechanical obstruction (requires draining system).
Actuator feels hot to touchNormal operation (slight warmth); internal fault (excessive heat).Slight warmth is normal. If excessively hot, disconnect power and replace actuator.

For persistent issues, it is recommended to contact a qualified heating engineer.

9. Garantía e soporte

For information regarding the warranty period and terms for your Drayton ZA5 Actuator, please refer to the documentation provided at the time of purchase or contact your retailer. Drayton products are typically covered by a manufacturer's warranty against defects in materials and workmanship.

For technical support or further assistance, please contact Drayton customer service or visit their official website. Ensure you have your product model number (ZA5) and part number (27650) ready when seeking support.

Documentos relacionados - ZA5

Preview Instrucións de funcionamento da válvula termostática para radiador Drayton TRV4
Instrucións de funcionamento e detalles técnicos para a válvula termostática de radiador de dous tubos Drayton TRV4. Abarca a instalación, o funcionamento, a limitación do rango, a protección contra xeadas e a resolución de problemas para un control óptimo da temperatura ambiente.
Preview Manual do instalador de Drayton: Guía completa de controis de calefacción
O Manual do instalador de Drayton ofrece información detallada sobre o produto, especificacións e diagramas de cableado para unha ampla gama de controis de calefacción Drayton, incluíndo termostatos, interruptores temporizados, programadores e válvulas, esenciais para instaladores profesionais.
Preview Instrucións de instalación e funcionamento do TRV de equilibrio automático Drayton
Guía completa para instalar e operar as válvulas termostáticas de radiador de dous tubos de Drayton con equilibrado automático, que garanten unha calefacción eficiente do fogar e unha mellora da eficiencia da caldeira.
Preview Guía de instalación da válvula de derivación automática Drayton
Guía oficial de instalación da válvula de derivación automática Drayton (ABV). Coñece as normas de construción, a integración do sistema, os procedementos de configuración, as características e as especificacións técnicas para un funcionamento eficiente do sistema de calefacción.
Preview Guía de configuración do sistema de calefacción intelixente Wiser | Drayton
Guía paso a paso para configurar o seu sistema de calefacción intelixente multizona Drayton Wiser, incluíndo a creación de contas, a conexión ao Hub e a ampliación de funcións.view.
Preview Guía de instalación e especificacións técnicas do termostato Drayton RTS
Instrucións de instalación completas, datos técnicos e diagramas de cableado para a gama de termostatos Drayton RTS (RTS1, RTS2, RTS3, RTS4, RTS9, RTS10). Inclúe detalles do modelo, consellos de localización, pasos de fixación e información de compatibilidade.