1. Introdución
This manual provides essential instructions for the safe and effective use of the Amphenol Ecomate C016 Series C01620H00310012 Circular Cable Mount Plug Connector. This connector is designed for industrial applications requiring reliable electrical connections, featuring a 3+PE configuration, screw pin contacts, and a threaded coupling mechanism. Please read this manual thoroughly before installation and operation.
2. Información de seguridade
Adherence to safety guidelines is crucial to prevent injury and damage to equipment. Always observe the following:
- Ensure all power sources are disconnected before installing, servicing, or disconnecting the connector.
- Só persoal cualificado debe realizar os procedementos de instalación e mantemento.
- Verify that the connector's voltage and current ratings are compatible with the application.
- Avoid exposing the connector to environments exceeding its specified operating conditions.
- Do not use damaged connectors or cables.
3. Produto rematadoview
O Amphenol C01620H00310012 is a robust circular cable mount plug from the Ecomate C016 series. Key features include:
- Configuración de contacto: 3 power contacts plus Protective Earth (3+PE).
- Tipo de contacto: Screw pin for secure and reliable wire termination.
- Coupling Style: Threaded for a strong and vibration-resistant connection.
- Revestimento de contacto: Silver for excellent conductivity and corrosion resistance.
- Conformidade: Conforme RoHS.

Figure 1: Disassembled components of the Amphenol C01620H00310012 circular connector. From left to right, it shows the cable gland nut, the main plug body with three silver-plated screw pins and a ground pin, an internal insert, and the coupling nut. The 'Amphenol' brand name is visible on the main plug body.
4. Configuración e instalación
This section outlines the general steps for assembling the cable mount plug. Specific wiring diagrams may vary based on your application and should be consulted separately.
- Prepare o cable: Strip the outer jacket of the cable to the appropriate length, exposing the individual insulated wires. Strip the insulation from the ends of the wires according to the screw terminal requirements.
- Thread Components: Slide the coupling nut and cable gland nut onto the cable in the correct order.
- Terminación de cable: Connect each wire to its corresponding screw pin contact within the connector insert. Ensure proper polarity and secure tightening of the screws. The 3+PE configuration typically includes three power contacts and one protective earth contact.
- Assemble Insert: Carefully insert the wired contact assembly into the main plug body, ensuring proper alignment and seating.
- Cable seguro: Tighten the cable gland nut onto the plug body to provide strain relief and environmental sealing for the cable.
- Asemblea final: Asegúrese de que todos os compoñentes estean ben fixados.
5. Instrucións de funcionamento
To connect the C01620H00310012 plug to a compatible receptacle:
- Aliñación: Align the keyways or polarization features of the plug with those of the receptacle.
- Inserción: Gently push the plug into the receptacle until the contacts engage.
- Acoplamento: Rotate the threaded coupling nut clockwise until it is fully tightened. This ensures a secure mechanical and electrical connection and maintains environmental sealing. Do not overtighten.
Para desconectar:
- Desconectar a enerxía: Ensure power to the circuit is OFF before attempting to disconnect.
- Unscrew Coupling: Rotate the threaded coupling nut counter-clockwise until it is loose.
- Withdraw Plug: Gently pull the plug straight out from the receptacle. Avoid twisting or yanking the cable.
6. Mantemento
Regular maintenance helps ensure the longevity and reliability of the connector.
- Inspección: Periodically inspect the connector for signs of wear, damage, corrosion, or loose connections. Check the cable entry for proper sealing.
- Limpeza: If necessary, clean the connector contacts and housing with a dry, lint-free cloth. For stubborn dirt, use a contact cleaner specifically designed for electrical components, ensuring it is non-conductive and leaves no residue. Ensure the connector is completely dry before re-energizing.
- Estanqueidade: Verify that the coupling nut and cable gland nut remain securely tightened.
7 Solución de problemas
If you encounter issues with your connector, consider the following common troubleshooting steps:
- No Electrical Connection:
- Check if the plug is fully inserted and the coupling nut is securely tightened.
- Inspect for damaged or bent contacts.
- Verify proper wire termination at the screw pins.
- Ensure power supply is active.
- Conexión intermitente:
- Apretar a porca de acoplamento.
- Inspect for loose wire connections at the screw pins.
- Check for corrosion or debris on contacts and clean if necessary.
- Dificultade para conectar/desconectar:
- Ensure proper alignment of keyways.
- Check for physical damage or deformation of the connector housing or pins.
If problems persist, contact a qualified electrician or Amphenol technical support.
8. Especificacións
| Característica | Detalle |
|---|---|
| Marca | Amphenol |
| Número de modelo | C016 20H003 100 12 |
| Gama de produtos | Ecomate C016 Series |
| Tipo de conector | Circular Cable Mount Plug |
| Número de contactos | 4 (3 power + Protective Earth) |
| Tipo de contacto | Pasador de parafuso |
| Coupling Style | Con rosca |
| Revestimento de contacto | Prata |
| Conforme RoHS | Si |
| Dimensións do produto | 6 x 2 x 6 polgadas; 1.6 onzas |
| Fabricante | AMPHENOL |
9. Garantía e soporte
For specific warranty information and technical support, please refer to the official Amphenol documentation or contact Amphenol directly through their official websitio web ou canles de atención ao cliente. Garde o recibo de compra para reclamacións de garantía.