The Pedrollo Vortex Zxm1A/40 is a submersible electric pump designed for domestic drainage of wastewater, including water containing suspended solids up to 40 mm in diameter. This pump is engineered for straightforward installation and reliable automatic operation in fixed installations. It is suitable for applications requiring efficient removal of dirty water.

Pedrollo Vortex Zxm1A/40 Electric Submersible Pump

Figura 1: Pedrollo Vortex Zxm1A/40 Electric Submersible Pump. This image shows the complete pump unit, featuring a silver-colored motor housing, an orange handle, a float switch, and a blue pump body with an outlet port.

2. Información de seguridade

Read all safety warnings and instructions carefully before installing, operating, or performing maintenance on this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

3. Configuración e instalación

3.1 Desembalaxe

Carefully remove the pump from its packaging. Inspect the pump for any signs of damage that may have occurred during transit. Retain packaging materials for future storage or transport.

3.2 Colocación

  1. Place the pump on a stable, flat surface in the lowest part of the area to be drained.
  2. Ensure the pump is fully submerged in water during operation. The float switch requires sufficient space to move freely for automatic operation.
  3. Avoid placing the pump directly on soft mud or sand, which could clog the intake. A solid base or platform is recommended.

3.3 Conexión da mangueira

  1. Connect a suitable discharge hose to the pump's outlet port. Ensure the connection is secure and watertight to prevent leaks.
  2. Route the discharge hose away from the area to be drained, ensuring it leads to an appropriate disposal point. Avoid kinks or sharp bends in the hose that could restrict flow.

3.4 Conexión eléctrica

  1. Verifique que a fonte de alimentación voltage matches the pump's requirements (220-240V).
  2. Connect the pump to a properly grounded electrical outlet protected by a Ground Fault Circuit Interrupter (GFCI).
  3. Ensure the power cable is not stretched, pinched, or damaged. Keep the cable away from sharp objects and hot surfaces.

4. Instrucións de funcionamento

4.1 Posta en marcha inicial

  1. After installation, ensure the pump is fully submerged and the float switch can move freely.
  2. Plug the pump into the GFCI-protected electrical outlet.
  3. The pump will start automatically when the water level rises and activates the float switch. It will stop when the water level drops and deactivates the float switch.

4.2 Operación normal

4.3 Apagado

To manually stop the pump, simply unplug it from the electrical outlet. For temporary cessation of automatic operation, secure the float switch in a position that prevents it from activating.

5. Mantemento

Un mantemento regular garante un rendemento óptimo e prolonga a vida útil da bomba. Desconecte sempre a alimentación antes de realizar calquera mantemento.

5.1 Limpeza

5.2 Almacenamento

If the pump will not be used for an extended period, especially in freezing conditions:

6 Solución de problemas

Antes de contactar co servizo de asistencia, volva aview os seguintes problemas e solucións comúns:

ProblemaCausa posibleSolución
A bomba non arranca.No power; Float switch not activated; Clogged impeller.Check power connection and GFCI; Ensure water level is high enough to activate float switch; Disconnect power and clear impeller.
A bomba funciona pero non sae auga ou o caudal é baixo.Discharge hose kinked or blocked; Pump intake clogged; Air lock; Low water level.Check and clear discharge hose; Disconnect power and clear pump intake; Briefly lift and lower pump to release air; Ensure pump is fully submerged.
Pump cycles on and off too frequently.Float switch restricted; Water level fluctuating rapidly.Check float switch for free movement; Ensure pump is placed in an area with stable water levels.

7. Especificacións

CaracterísticaDetalle
ModeloZxm1A/40
Referencia do fabricantePSG 48SDZE4AA1
MarcaPedrollo (Comid is listed as brand on Amazon, but manufacturer is Pedrollo)
Poder0.85 HP
Voltage220-240 voltios
Fonte de enerxíaEléctrico con cable
Caudal máximoUp to 400 l/min (24.0 m³/h)
Cabeza máximaAta 11 m
Max Solid Particle SizeUp to 40 mm diameter
Peso do elemento13 quilogramos

8. Garantía e soporte

For warranty information, technical support, or spare parts availability, please refer to the official Pedrollo websitio web ou póñase en contacto co seu distribuidor autorizado. Garde o recibo de compra como proba de compra para reclamacións de garantía.

Availability of spare parts information is not provided in the product details. Please consult the manufacturer directly for specific inquiries.

Documentos relacionados - Zxm1A/40

Preview Pedrollo VX Vortex Submersible Pumps - Technical Specifications and Performance Curves
Detailed technical specifications, performance curves, dimensions, and installation guidelines for Pedrollo VX Vortex submersible pumps. Covers models VX40/50, VX55/50, VX40/65, VX55/65, VX75/65, VX40/80, VX55/80, and VX75/80.
Preview Bombas mergulladas Pedrollo TRITUS con trituradora: especificacións técnicas e aplicacións
Explore as especificacións técnicas, as curvas de rendemento, as dimensións e as pautas de instalación das bombas submerxibles Pedrollo TRITUS con trituradoras. Ideais para a xestión de augas residuais domésticas e civís.
Preview Pedrollo VXC Submersible Pumps: Performance, Specifications, and Components
Detailed information on Pedrollo VXC series submersible pumps, including performance data, application limits, technical specifications, dimensions, materials, and components. Suitable for sewage, domestic use, and civil applications.
Preview VORTEX VXC4 Series Submersible Pumps - Technical Data and Specifications
Detailed technical specifications, performance curves, dimensions, and construction features for the VORTEX VXC4 series of 4-pole submersible pumps from PEDROLLO. Suitable for dirty water, civil, and industrial use.
Preview Pedrollo RX-VORTEX Submersible Pumps for Drainage - Technical Data and Performance
Detailed technical specifications, performance curves, dimensions, and materials for Pedrollo RX-VORTEX submersible pumps designed for drainage applications. Includes information on flow rates, head, power, absorption, and component details.
Preview Pompe Elettrosommergibili Pedrollo: DAVIS, 4-BLOCK, SALI, PRO 100AR - Istruzioni d'Uso
Guida completa alle pompe elettrosommergibili Pedrollo, inclusi i modelli DAVIS, 4-BLOCK, SALI, PRO 100AR, 3SR, 4SR, 4HR, 6SR, 6ST, 6HR, 4PD, 4PS, 6PD, 6PSR. Fornisce dettagli su installazione, uso sicuro, limiti operativi e manutenzione per un efficiente approvvigionamento idrico.